Hydraulic Retention Time given Food to Microorganism Ratio Solution

STEP 0: Pre-Calculation Summary
Formula Used
Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time)
θs = FM/(Sh*Xh)
This formula uses 4 Variables
Variables Used
Hydraulic Retention Time in Seconds - (Measured in Second) - Hydraulic Retention Time in Seconds is referred as the ratio between the reactor volume and the feed flow rate, it represents the average time the cells and substrates stay inside the reactor.
F:M Ratio - (Measured in 1 Per Second) - F:M Ratio refers to the amount of organic matter (food) available to the microorganisms in the system to the amount of microbial biomass present.
Influent Substrate Concentration h - (Measured in Kilogram per Cubic Meter) - Influent Substrate Concentration h refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant.
MLVSS Hydraulic Retention Time - (Measured in Kilogram per Cubic Meter) - MLVSS Hydraulic Retention Time refers to the amount of active microbial biomass, which is crucial for the biological degradation of organic pollutants.
STEP 1: Convert Input(s) to Base Unit
F:M Ratio: 0.2 1 Per Day --> 2.31481481481481E-06 1 Per Second (Check conversion ​here)
Influent Substrate Concentration h: 50 Milligram per Liter --> 0.05 Kilogram per Cubic Meter (Check conversion ​here)
MLVSS Hydraulic Retention Time: 0.0065 Milligram per Liter --> 6.5E-06 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
θs = FM/(Sh*Xh) --> 2.31481481481481E-06/(0.05*6.5E-06)
Evaluating ... ...
θs = 7.12250712250711
STEP 3: Convert Result to Output's Unit
7.12250712250711 Second --> No Conversion Required
FINAL ANSWER
7.12250712250711 7.122507 Second <-- Hydraulic Retention Time in Seconds
(Calculation completed in 00.005 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Hydraulic Retention Time Calculators

Hydraulic Retention Time given Food to Microorganism Ratio
​ LaTeX ​ Go Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time)
Hydraulic Retention Time given Volume of Rapid Mix Basin
​ LaTeX ​ Go Hydraulic Retention Time in Seconds = Volume of Rapid Mix Basin/Francis Discharge with Suppressed End
Hydraulic Retention Time given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Hydraulic Retention = (Volume/Influent Sludge Flow Rate)

Hydraulic Retention Time given Food to Microorganism Ratio Formula

​LaTeX ​Go
Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time)
θs = FM/(Sh*Xh)

What is Food to Microorganism (F:M) Ratio?

F:M Ratio is simply a ratio of the “food” or BOD5 of the incoming waste, to the
the concentration of “microorganisms” in the aeration tank or MLVSS.

How to Calculate Hydraulic Retention Time given Food to Microorganism Ratio?

Hydraulic Retention Time given Food to Microorganism Ratio calculator uses Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time) to calculate the Hydraulic Retention Time in Seconds, The Hydraulic Retention Time given Food to Microorganism Ratio formula is defined as the measure of the average length of time that a soluble compound remains in a constructed bioreactor. Hydraulic Retention Time in Seconds is denoted by θs symbol.

How to calculate Hydraulic Retention Time given Food to Microorganism Ratio using this online calculator? To use this online calculator for Hydraulic Retention Time given Food to Microorganism Ratio, enter F:M Ratio (FM), Influent Substrate Concentration h (Sh) & MLVSS Hydraulic Retention Time (Xh) and hit the calculate button. Here is how the Hydraulic Retention Time given Food to Microorganism Ratio calculation can be explained with given input values -> 7.122507 = 2.31481481481481E-06/(0.05*6.5E-06).

FAQ

What is Hydraulic Retention Time given Food to Microorganism Ratio?
The Hydraulic Retention Time given Food to Microorganism Ratio formula is defined as the measure of the average length of time that a soluble compound remains in a constructed bioreactor and is represented as θs = FM/(Sh*Xh) or Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time). F:M Ratio refers to the amount of organic matter (food) available to the microorganisms in the system to the amount of microbial biomass present, Influent Substrate Concentration h refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant & MLVSS Hydraulic Retention Time refers to the amount of active microbial biomass, which is crucial for the biological degradation of organic pollutants.
How to calculate Hydraulic Retention Time given Food to Microorganism Ratio?
The Hydraulic Retention Time given Food to Microorganism Ratio formula is defined as the measure of the average length of time that a soluble compound remains in a constructed bioreactor is calculated using Hydraulic Retention Time in Seconds = F:M Ratio/(Influent Substrate Concentration h*MLVSS Hydraulic Retention Time). To calculate Hydraulic Retention Time given Food to Microorganism Ratio, you need F:M Ratio (FM), Influent Substrate Concentration h (Sh) & MLVSS Hydraulic Retention Time (Xh). With our tool, you need to enter the respective value for F:M Ratio, Influent Substrate Concentration h & MLVSS Hydraulic Retention Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Hydraulic Retention Time in Seconds?
In this formula, Hydraulic Retention Time in Seconds uses F:M Ratio, Influent Substrate Concentration h & MLVSS Hydraulic Retention Time. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Hydraulic Retention Time in Seconds = Volume of Rapid Mix Basin/Francis Discharge with Suppressed End
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!