Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel
Rrf = (rpf*ss)/s
This formula uses 4 Variables
Variables Used
Hydraulic Mean Depth while Running Full - (Measured in Meter) - Hydraulic Mean Depth while Running Full refers to the ratio of the pipe's full cross-sectional area to its full wetted perimeter.
Hydraulic Mean Depth for Partially Full - (Measured in Meter) - Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels.
Bed Slope of Partial Flow - Bed Slope of Partial Flow means the slope at which partial flow is occurring.
Bed Slope of Channel - Bed Slope of Channel refers to the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage.
STEP 1: Convert Input(s) to Base Unit
Hydraulic Mean Depth for Partially Full: 3.2 Meter --> 3.2 Meter No Conversion Required
Bed Slope of Partial Flow: 0.0018 --> No Conversion Required
Bed Slope of Channel: 0.001 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rrf = (rpf*ss)/s --> (3.2*0.0018)/0.001
Evaluating ... ...
Rrf = 5.76
STEP 3: Convert Result to Output's Unit
5.76 Meter --> No Conversion Required
FINAL ANSWER
5.76 Meter <-- Hydraulic Mean Depth while Running Full
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Hydraulic Mean Depth for Full Flow Calculators

Hydraulic Mean Depth for Full Flow given Self Cleansing Velocity
​ LaTeX ​ Go Hydraulic Mean Depth while Running Full = Hydraulic Mean Depth for Partially Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*sqrt(Bed Slope Ratio)))^(3/2)
Hydraulic Mean Depth for Full Flow given Velocity Ratio
​ LaTeX ​ Go Hydraulic Mean Depth while Running Full = Hydraulic Mean Depth for Partially Full/(Velocity Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*sqrt(Bed Slope Ratio)))^(3/2)
Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow
​ LaTeX ​ Go Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel

Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow Formula

​LaTeX ​Go
Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel
Rrf = (rpf*ss)/s

What is Hydraulic mean depth ratio ?

The hydraulic mean depth ratio is the comparison of the hydraulic mean depth (flow area divided by wetted perimeter) of a partially full pipe to that of a fully running pipe. This ratio helps in analyzing the flow efficiency and determining the capacity of the pipe under different flow conditions, aiding in the design and management of sewer systems.

How to Calculate Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow?

Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow calculator uses Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel to calculate the Hydraulic Mean Depth while Running Full, The Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow is defined as the ratio of the pipe's full cross-sectional area to its full wetted perimeter. Hydraulic Mean Depth while Running Full is denoted by Rrf symbol.

How to calculate Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow using this online calculator? To use this online calculator for Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow, enter Hydraulic Mean Depth for Partially Full (rpf), Bed Slope of Partial Flow (ss) & Bed Slope of Channel (s) and hit the calculate button. Here is how the Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow calculation can be explained with given input values -> 6400 = (3.2*bed_slope_of_partial_flow)/0.001.

FAQ

What is Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow?
The Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow is defined as the ratio of the pipe's full cross-sectional area to its full wetted perimeter and is represented as Rrf = (rpf*ss)/s or Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel. Hydraulic Mean Depth for Partially Full refers to the cross-sectional area of flow divided by the wetted perimeter, adapting to varying water levels, Bed Slope of Partial Flow means the slope at which partial flow is occurring & Bed Slope of Channel refers to the gradient or incline of a channel's bed, influencing the velocity and direction of water flow, typically measured as a ratio or percentage.
How to calculate Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow?
The Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow is defined as the ratio of the pipe's full cross-sectional area to its full wetted perimeter is calculated using Hydraulic Mean Depth while Running Full = (Hydraulic Mean Depth for Partially Full*Bed Slope of Partial Flow)/Bed Slope of Channel. To calculate Hydraulic Mean Depth for Full Flow given Bed Slope for Partial Flow, you need Hydraulic Mean Depth for Partially Full (rpf), Bed Slope of Partial Flow (ss) & Bed Slope of Channel (s). With our tool, you need to enter the respective value for Hydraulic Mean Depth for Partially Full, Bed Slope of Partial Flow & Bed Slope of Channel and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Hydraulic Mean Depth while Running Full?
In this formula, Hydraulic Mean Depth while Running Full uses Hydraulic Mean Depth for Partially Full, Bed Slope of Partial Flow & Bed Slope of Channel. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Hydraulic Mean Depth while Running Full = Hydraulic Mean Depth for Partially Full/(Velocity Ratio/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*sqrt(Bed Slope Ratio)))^(3/2)
  • Hydraulic Mean Depth while Running Full = Hydraulic Mean Depth for Partially Full/((Velocity in a Partially Running Sewer/Velocity While Running Full)/((Roughness Coefficient for Running Full/Roughness Coefficient Partially Full)*sqrt(Bed Slope Ratio)))^(3/2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!