Height of Settling Zone given Detention Time Solution

STEP 0: Pre-Calculation Summary
Formula Used
Height of Crack = (Detention Time*Discharge)/(Length*Width)
h = (Td*Q)/(L*w)
This formula uses 5 Variables
Variables Used
Height of Crack - (Measured in Meter) - The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Detention Time - (Measured in Second) - The Detention Time refers to the amount of time that a fluid (or any substance) spends within a particular component of a system.
Discharge - (Measured in Cubic Meter per Second) - The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Length - (Measured in Meter) - The Length refers to the measurement of the distance between two points.
Width - (Measured in Meter) - The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
STEP 1: Convert Input(s) to Base Unit
Detention Time: 3 Minute --> 180 Second (Check conversion ​here)
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Length: 12 Meter --> 12 Meter No Conversion Required
Width: 2.29 Meter --> 2.29 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h = (Td*Q)/(L*w) --> (180*1.01)/(12*2.29)
Evaluating ... ...
h = 6.61572052401747
STEP 3: Convert Result to Output's Unit
6.61572052401747 Meter -->6615.72052401747 Millimeter (Check conversion ​here)
FINAL ANSWER
6615.72052401747 6615.721 Millimeter <-- Height of Crack
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Height of Settling Zone Calculators

Height of Settling Zone given Height at Outlet Zone with respect to Discharge
​ LaTeX ​ Go Height of Crack = Outer Height*Discharge/(Length*Width*Falling Speed)
Height of Settling Zone given Detention Time
​ LaTeX ​ Go Height of Crack = (Detention Time*Discharge)/(Length*Width)
Height of Settling Zone given Height at Outlet Zone with respect to Settling Velocity
​ LaTeX ​ Go Height of Crack = Outer Height*Settling Velocity/Falling Speed
Height of Settling Zone given Ratio of Removal with respect to Tank Height
​ LaTeX ​ Go Height of Crack = Outer Height/Removal Ratio

Height of Settling Zone given Detention Time Formula

​LaTeX ​Go
Height of Crack = (Detention Time*Discharge)/(Length*Width)
h = (Td*Q)/(L*w)

What is Detention Time?

Detention Time is the time required for a given amount of water or wastewater to pass through a tank at a given rate of flow.

How to Calculate Height of Settling Zone given Detention Time?

Height of Settling Zone given Detention Time calculator uses Height of Crack = (Detention Time*Discharge)/(Length*Width) to calculate the Height of Crack, The Height of Settling Zone given Detention Time formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent. Height of Crack is denoted by h symbol.

How to calculate Height of Settling Zone given Detention Time using this online calculator? To use this online calculator for Height of Settling Zone given Detention Time, enter Detention Time (Td), Discharge (Q), Length (L) & Width (w) and hit the calculate button. Here is how the Height of Settling Zone given Detention Time calculation can be explained with given input values -> 1.6E+7 = (180*1.01)/(12*2.29).

FAQ

What is Height of Settling Zone given Detention Time?
The Height of Settling Zone given Detention Time formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent and is represented as h = (Td*Q)/(L*w) or Height of Crack = (Detention Time*Discharge)/(Length*Width). The Detention Time refers to the amount of time that a fluid (or any substance) spends within a particular component of a system, The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time, The Length refers to the measurement of the distance between two points & The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
How to calculate Height of Settling Zone given Detention Time?
The Height of Settling Zone given Detention Time formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent is calculated using Height of Crack = (Detention Time*Discharge)/(Length*Width). To calculate Height of Settling Zone given Detention Time, you need Detention Time (Td), Discharge (Q), Length (L) & Width (w). With our tool, you need to enter the respective value for Detention Time, Discharge, Length & Width and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Height of Crack?
In this formula, Height of Crack uses Detention Time, Discharge, Length & Width. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Height of Crack = Outer Height*Discharge/(Length*Width*Falling Speed)
  • Height of Crack = Outer Height*Settling Velocity/Falling Speed
  • Height of Crack = Outer Height/Removal Ratio
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!