Height of Settling Zone given Cross-section Area of Sedimentation Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Height of Crack = Cross-Sectional Area/Width
h = Acs/w
This formula uses 3 Variables
Variables Used
Height of Crack - (Measured in Meter) - The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Cross-Sectional Area - (Measured in Square Meter) - The Cross-Sectional Area of a sedimentation tank refers to the vertical slice of the tank, typically viewed from the side, that shows the depth and width.
Width - (Measured in Meter) - The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
STEP 1: Convert Input(s) to Base Unit
Cross-Sectional Area: 28 Square Meter --> 28 Square Meter No Conversion Required
Width: 2.29 Meter --> 2.29 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h = Acs/w --> 28/2.29
Evaluating ... ...
h = 12.2270742358079
STEP 3: Convert Result to Output's Unit
12.2270742358079 Meter -->12227.0742358079 Millimeter (Check conversion ​here)
FINAL ANSWER
12227.0742358079 12227.07 Millimeter <-- Height of Crack
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Height of Settling Zone Calculators

Height of Settling Zone given Height at Outlet Zone with respect to Discharge
​ LaTeX ​ Go Height of Crack = Outer Height*Discharge/(Length*Width*Falling Speed)
Height of Settling Zone given Detention Time
​ LaTeX ​ Go Height of Crack = (Detention Time*Discharge)/(Length*Width)
Height of Settling Zone given Height at Outlet Zone with respect to Settling Velocity
​ LaTeX ​ Go Height of Crack = Outer Height*Settling Velocity/Falling Speed
Height of Settling Zone given Ratio of Removal with respect to Tank Height
​ LaTeX ​ Go Height of Crack = Outer Height/Removal Ratio

Height of Settling Zone given Cross-section Area of Sedimentation Tank Formula

​LaTeX ​Go
Height of Crack = Cross-Sectional Area/Width
h = Acs/w

What is Sedimentation?

Sedimentation is the tendency for particles in suspension to settle out of the fluid in which they are entrained and come to rest against a barrier. This is due to their motion through the fluid in response to the forces acting on them: these forces can be due to gravity, centrifugal acceleration, or electromagnetism.

How to Calculate Height of Settling Zone given Cross-section Area of Sedimentation Tank?

Height of Settling Zone given Cross-section Area of Sedimentation Tank calculator uses Height of Crack = Cross-Sectional Area/Width to calculate the Height of Crack, The Height of Settling Zone given Cross-section Area of Sedimentation Tank formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent. Height of Crack is denoted by h symbol.

How to calculate Height of Settling Zone given Cross-section Area of Sedimentation Tank using this online calculator? To use this online calculator for Height of Settling Zone given Cross-section Area of Sedimentation Tank, enter Cross-Sectional Area (Acs) & Width (w) and hit the calculate button. Here is how the Height of Settling Zone given Cross-section Area of Sedimentation Tank calculation can be explained with given input values -> 1.2E+7 = 28/2.29.

FAQ

What is Height of Settling Zone given Cross-section Area of Sedimentation Tank?
The Height of Settling Zone given Cross-section Area of Sedimentation Tank formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent and is represented as h = Acs/w or Height of Crack = Cross-Sectional Area/Width. The Cross-Sectional Area of a sedimentation tank refers to the vertical slice of the tank, typically viewed from the side, that shows the depth and width & The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
How to calculate Height of Settling Zone given Cross-section Area of Sedimentation Tank?
The Height of Settling Zone given Cross-section Area of Sedimentation Tank formula is defined as the vertical distance through which water flows and particles settle under gravity before the water exits the tank as clarified effluent is calculated using Height of Crack = Cross-Sectional Area/Width. To calculate Height of Settling Zone given Cross-section Area of Sedimentation Tank, you need Cross-Sectional Area (Acs) & Width (w). With our tool, you need to enter the respective value for Cross-Sectional Area & Width and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Height of Crack?
In this formula, Height of Crack uses Cross-Sectional Area & Width. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Height of Crack = (Detention Time*Discharge)/(Length*Width)
  • Height of Crack = Outer Height*Discharge/(Length*Width*Falling Speed)
  • Height of Crack = Outer Height*Settling Velocity/Falling Speed
Let Others Know