Height of Saturated Zone given Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2)
H = sqrt(((2*Q*L)/k)+(Ho)^2)
This formula uses 1 Functions, 5 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Height of Saturated Zone - (Measured in Meter) - The Height of saturated Zone refers to the height of the ground level at the infiltration gallery which is considered at some distance from the source.
Discharge - (Measured in Cubic Meter per Second) - The Discharge refers to the volume of fluid passing through a cross-sectional area of a stream or pipe per unit time.
Distance Between IG and Source - (Measured in Meter) - The Distance Between IG and Source refers to the distance between the infiltration gallery and the source point.
Coefficient of Permeability - (Measured in Meter per Second) - The Coefficient of Permeability refers to the soil characteristics describes how easily a liquid will move through the soil.
Depth of Water in Infiltration Gallery - (Measured in Meter) - The Depth of Water in Infiltration Gallery refers to the depth of water which is considered inside the infiltration gallery.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Distance Between IG and Source: 10 Meter --> 10 Meter No Conversion Required
Coefficient of Permeability: 10 Centimeter per Second --> 0.1 Meter per Second (Check conversion ​here)
Depth of Water in Infiltration Gallery: 10.31 Meter --> 10.31 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
H = sqrt(((2*Q*L)/k)+(Ho)^2) --> sqrt(((2*1.01*10)/0.1)+(10.31)^2)
Evaluating ... ...
H = 17.5583626799312
STEP 3: Convert Result to Output's Unit
17.5583626799312 Meter --> No Conversion Required
FINAL ANSWER
17.5583626799312 17.55836 Meter <-- Height of Saturated Zone
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Flow into Infiltration Gallery Calculators

Height of Saturated Zone given Discharge
​ LaTeX ​ Go Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2)
Discharge Passing through Vertical Section of Infiltration Gallery
​ LaTeX ​ Go Discharge = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Distance Between IG and Source)
Distance between Infiltration Gallery and Source given Discharge
​ LaTeX ​ Go Distance Between IG and Source = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Discharge)
Coefficient of Permeability given Discharge
​ LaTeX ​ Go Coefficient of Permeability = Discharge/(((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2)/(2*Distance Between IG and Source))

Height of Saturated Zone given Discharge Formula

​LaTeX ​Go
Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2)
H = sqrt(((2*Q*L)/k)+(Ho)^2)

What is Infiltration Gallery ?

An infiltration gallery is a horizontal drain made from open jointed or perforated pipes, or a block drain, which is laid below the water table and collects groundwater. Infiltration galleries need soils that are permeable to allow suffi- cient water to be collected.

How to Calculate Height of Saturated Zone given Discharge?

Height of Saturated Zone given Discharge calculator uses Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2) to calculate the Height of Saturated Zone, The Height of Saturated Zone given Discharge is defined as the value of height of saturated zone when we have prior information of other parameters used. Height of Saturated Zone is denoted by H symbol.

How to calculate Height of Saturated Zone given Discharge using this online calculator? To use this online calculator for Height of Saturated Zone given Discharge, enter Discharge (Q), Distance Between IG and Source (L), Coefficient of Permeability (k) & Depth of Water in Infiltration Gallery (Ho) and hit the calculate button. Here is how the Height of Saturated Zone given Discharge calculation can be explained with given input values -> 17.55836 = sqrt(((2*1.01*10)/0.1)+(10.31)^2).

FAQ

What is Height of Saturated Zone given Discharge?
The Height of Saturated Zone given Discharge is defined as the value of height of saturated zone when we have prior information of other parameters used and is represented as H = sqrt(((2*Q*L)/k)+(Ho)^2) or Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2). The Discharge refers to the volume of fluid passing through a cross-sectional area of a stream or pipe per unit time, The Distance Between IG and Source refers to the distance between the infiltration gallery and the source point, The Coefficient of Permeability refers to the soil characteristics describes how easily a liquid will move through the soil & The Depth of Water in Infiltration Gallery refers to the depth of water which is considered inside the infiltration gallery.
How to calculate Height of Saturated Zone given Discharge?
The Height of Saturated Zone given Discharge is defined as the value of height of saturated zone when we have prior information of other parameters used is calculated using Height of Saturated Zone = sqrt(((2*Discharge*Distance Between IG and Source)/Coefficient of Permeability)+(Depth of Water in Infiltration Gallery)^2). To calculate Height of Saturated Zone given Discharge, you need Discharge (Q), Distance Between IG and Source (L), Coefficient of Permeability (k) & Depth of Water in Infiltration Gallery (Ho). With our tool, you need to enter the respective value for Discharge, Distance Between IG and Source, Coefficient of Permeability & Depth of Water in Infiltration Gallery and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.