Height at Outlet Zone given Ratio of Removal with respect to Tank Height Solution

STEP 0: Pre-Calculation Summary
Formula Used
Outer Height = Removal Ratio*Height of Crack
H = Rr*h
This formula uses 3 Variables
Variables Used
Outer Height - (Measured in Meter) - The Outer Height refers to the external vertical dimension of an object or structure.
Removal Ratio - Removal Ratio is the total amount of sludge removed from the sedimentation tank.
Height of Crack - (Measured in Meter) - The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
STEP 1: Convert Input(s) to Base Unit
Removal Ratio: 5 --> No Conversion Required
Height of Crack: 12000 Millimeter --> 12 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
H = Rr*h --> 5*12
Evaluating ... ...
H = 60
STEP 3: Convert Result to Output's Unit
60 Meter --> No Conversion Required
FINAL ANSWER
60 Meter <-- Outer Height
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Height at Outlet Zone Calculators

Height at Outlet Zone with respect to Discharge
​ LaTeX ​ Go Outer Height = (Length*Width*Height of Crack*Falling Speed)/Discharge
Height at Outlet Zone with respect to Area of Tank
​ LaTeX ​ Go Outer Height = Falling Speed*Height of Crack*Area/Discharge
Height at Outlet Zone given Falling Speed of Smaller Particle
​ LaTeX ​ Go Outer Height = Falling Speed*Detention Time h
Height at Outlet Zone given Ratio of Removal with respect to Tank Height
​ LaTeX ​ Go Outer Height = Removal Ratio*Height of Crack

Height at Outlet Zone given Ratio of Removal with respect to Tank Height Formula

​LaTeX ​Go
Outer Height = Removal Ratio*Height of Crack
H = Rr*h

What is Removal Ratio ?

Removal Ratio is defined as the ratio of the amount of sludge being removed from the sedimentation tank.

How to Calculate Height at Outlet Zone given Ratio of Removal with respect to Tank Height?

Height at Outlet Zone given Ratio of Removal with respect to Tank Height calculator uses Outer Height = Removal Ratio*Height of Crack to calculate the Outer Height, The Height at Outlet Zone given Ratio of Removal with respect to Tank Height formula is defined as the vertical distance between the bottom of a channel, pipe, or conduit and the top of the flow at the outlet. Outer Height is denoted by H symbol.

How to calculate Height at Outlet Zone given Ratio of Removal with respect to Tank Height using this online calculator? To use this online calculator for Height at Outlet Zone given Ratio of Removal with respect to Tank Height, enter Removal Ratio (Rr) & Height of Crack (h) and hit the calculate button. Here is how the Height at Outlet Zone given Ratio of Removal with respect to Tank Height calculation can be explained with given input values -> 60 = 5*12.

FAQ

What is Height at Outlet Zone given Ratio of Removal with respect to Tank Height?
The Height at Outlet Zone given Ratio of Removal with respect to Tank Height formula is defined as the vertical distance between the bottom of a channel, pipe, or conduit and the top of the flow at the outlet and is represented as H = Rr*h or Outer Height = Removal Ratio*Height of Crack. Removal Ratio is the total amount of sludge removed from the sedimentation tank & The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
How to calculate Height at Outlet Zone given Ratio of Removal with respect to Tank Height?
The Height at Outlet Zone given Ratio of Removal with respect to Tank Height formula is defined as the vertical distance between the bottom of a channel, pipe, or conduit and the top of the flow at the outlet is calculated using Outer Height = Removal Ratio*Height of Crack. To calculate Height at Outlet Zone given Ratio of Removal with respect to Tank Height, you need Removal Ratio (Rr) & Height of Crack (h). With our tool, you need to enter the respective value for Removal Ratio & Height of Crack and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Outer Height?
In this formula, Outer Height uses Removal Ratio & Height of Crack. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Outer Height = Falling Speed*Detention Time h
  • Outer Height = (Length*Width*Height of Crack*Falling Speed)/Discharge
  • Outer Height = Falling Speed*Height of Crack*Area/Discharge
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp