Head given Discharge over Cipolletti Weir Solution

STEP 0: Pre-Calculation Summary
Formula Used
Height of Water above Crest of Weir = (Discharge by Cipolletti/(1.86*Length of Weir Crest))^(2/3)
Sw = (QC/(1.86*Lw))^(2/3)
This formula uses 3 Variables
Variables Used
Height of Water above Crest of Weir - (Measured in Meter) - Height of Water above Crest of Weir is defined as the water surface height above crest.
Discharge by Cipolletti - (Measured in Cubic Meter per Second) - Discharge by Cipolletti is the rate of flow of a liquid.
Length of Weir Crest - (Measured in Meter) - Length of Weir Crest is the measurement or extent of Weir Crest from end to end.
STEP 1: Convert Input(s) to Base Unit
Discharge by Cipolletti: 15 Cubic Meter per Second --> 15 Cubic Meter per Second No Conversion Required
Length of Weir Crest: 3 Meter --> 3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Sw = (QC/(1.86*Lw))^(2/3) --> (15/(1.86*3))^(2/3)
Evaluating ... ...
Sw = 1.93332428713651
STEP 3: Convert Result to Output's Unit
1.93332428713651 Meter --> No Conversion Required
FINAL ANSWER
1.93332428713651 1.933324 Meter <-- Height of Water above Crest of Weir
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

Flow Over a Trapizoidal Weir or Notch Calculators

Discharge over Trapezoidal Notch if overall Coefficient of Discharge for Trapezoidal notch
​ LaTeX ​ Go Discharge by Cipolletti = ((Coefficient of Discharge*sqrt(2*Acceleration due to Gravity)*Height of Water above Crest of Weir^(3/2))*((2/3)*Length of Weir Crest+(8/15)*Height of Water above Crest of Weir*tan(Theta/2)))
Coefficient of Discharge given Discharge for Cipolletti Weir
​ LaTeX ​ Go Coefficient of Discharge = (Discharge by Cipolletti*3)/(2*sqrt(2*Acceleration due to Gravity)*Length of Weir Crest*Height of Water above Crest of Weir^(3/2))
Length of Crest given Discharge for Cipolletti Weir
​ LaTeX ​ Go Length of Weir Crest = (3*Discharge by Cipolletti)/(2*Coefficient of Discharge*sqrt(2*Acceleration due to Gravity)*Height of Water above Crest of Weir^(3/2))
Discharge for Cipolletti Weir
​ LaTeX ​ Go Discharge by Cipolletti = (2/3)*Coefficient of Discharge*sqrt(2*Acceleration due to Gravity)*Length of Weir Crest*Height of Water above Crest of Weir^(3/2)

Head given Discharge over Cipolletti Weir Formula

​LaTeX ​Go
Height of Water above Crest of Weir = (Discharge by Cipolletti/(1.86*Length of Weir Crest))^(2/3)
Sw = (QC/(1.86*Lw))^(2/3)

What is meant by Discharge?

The Discharge(Q) over a Cipolletti Weir by Francis, cipolletti is a measure of the quantity of any fluid flow over unit time. The quantity may be either volume or mass.

What is Cipolletti weir?

A standard Cipoletti weir is trapezoidal in shape. The crest and sides of the weir plate are placed far enough from the bottom and sides of the approach channel to produce full contraction. The sides incline outwardly at a slope of 1 horizontal to 4 vertical.

How to Calculate Head given Discharge over Cipolletti Weir?

Head given Discharge over Cipolletti Weir calculator uses Height of Water above Crest of Weir = (Discharge by Cipolletti/(1.86*Length of Weir Crest))^(2/3) to calculate the Height of Water above Crest of Weir, Head given discharge over Cipolletti weir is specific measurement of water pressure or total energy per unit weight above datum. Height of Water above Crest of Weir is denoted by Sw symbol.

How to calculate Head given Discharge over Cipolletti Weir using this online calculator? To use this online calculator for Head given Discharge over Cipolletti Weir, enter Discharge by Cipolletti (QC) & Length of Weir Crest (Lw) and hit the calculate button. Here is how the Head given Discharge over Cipolletti Weir calculation can be explained with given input values -> 1.933324 = (15/(1.86*3))^(2/3).

FAQ

What is Head given Discharge over Cipolletti Weir?
Head given discharge over Cipolletti weir is specific measurement of water pressure or total energy per unit weight above datum and is represented as Sw = (QC/(1.86*Lw))^(2/3) or Height of Water above Crest of Weir = (Discharge by Cipolletti/(1.86*Length of Weir Crest))^(2/3). Discharge by Cipolletti is the rate of flow of a liquid & Length of Weir Crest is the measurement or extent of Weir Crest from end to end.
How to calculate Head given Discharge over Cipolletti Weir?
Head given discharge over Cipolletti weir is specific measurement of water pressure or total energy per unit weight above datum is calculated using Height of Water above Crest of Weir = (Discharge by Cipolletti/(1.86*Length of Weir Crest))^(2/3). To calculate Head given Discharge over Cipolletti Weir, you need Discharge by Cipolletti (QC) & Length of Weir Crest (Lw). With our tool, you need to enter the respective value for Discharge by Cipolletti & Length of Weir Crest and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Height of Water above Crest of Weir?
In this formula, Height of Water above Crest of Weir uses Discharge by Cipolletti & Length of Weir Crest. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Height of Water above Crest of Weir = ((3*Discharge by Cipolletti)/(2*Coefficient of Discharge*sqrt(2*Acceleration due to Gravity)*Length of Weir Crest))^(2/3)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!