Half Scale Resistance for Series Type Ohmmeter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance)
Rh = (E*R2)/(If*R2+If*Rm)
This formula uses 5 Variables
Variables Used
Half Scale Resistance - (Measured in Ohm) - Half Scale Resistance refers to the resistance value halfway between the maximum and minimum resistance of a variable resistor or potentiometer, typically used to calibrate or set reference points.
Voltage Source - (Measured in Volt) - Voltage Source refers to as a fundamental element that supplies electrical energy to a circuit.
Zero Adjusting Resistance - (Measured in Ohm) - Zero Adjusting Resistance refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument.
Current Full Scale Reading - (Measured in Ampere) - Current Full Scale Reading represents the maximum current that the ohmmeter will pass through the resistor when it's being measured at its highest resistance value.
Meter Resistance - (Measured in Ohm) - Meter Resistance refers to the internal resistance of a measuring instrument. This resistance is inherent to the design of the instrument and affects the accuracy of measurements made by the device.
STEP 1: Convert Input(s) to Base Unit
Voltage Source: 15.5 Volt --> 15.5 Volt No Conversion Required
Zero Adjusting Resistance: 36 Ohm --> 36 Ohm No Conversion Required
Current Full Scale Reading: 0.2 Ampere --> 0.2 Ampere No Conversion Required
Meter Resistance: 75 Ohm --> 75 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rh = (E*R2)/(If*R2+If*Rm) --> (15.5*36)/(0.2*36+0.2*75)
Evaluating ... ...
Rh = 25.1351351351351
STEP 3: Convert Result to Output's Unit
25.1351351351351 Ohm --> No Conversion Required
FINAL ANSWER
25.1351351351351 25.13514 Ohm <-- Half Scale Resistance
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has verified this Calculator and 25+ more calculators!

Series Type Calculators

Half Scale Resistance for Series Type Ohmmeter
​ LaTeX ​ Go Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance)
Shunt Adjustable Resistance for Series Type Ohmmeter
​ LaTeX ​ Go Zero Adjusting Resistance = (Current Full Scale Reading*Half Scale Resistance*Meter Resistance)/(Voltage Source-(Current Full Scale Reading*Half Scale Resistance))
Current Limiting Resistance for Series Type Ohmmeter
​ LaTeX ​ Go Current Limiting Resistance = Half Scale Resistance-((Current Full Scale Reading*Meter Resistance*Half Scale Resistance)/Voltage Source)

Half Scale Resistance for Series Type Ohmmeter Formula

​LaTeX ​Go
Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance)
Rh = (E*R2)/(If*R2+If*Rm)

What is Half Scale Operation?

If the unknown resistance is adjusted such that the basic meter in the ohmmeter shows half of full scale reading, It is called Half Scale Operation.

How to Calculate Half Scale Resistance for Series Type Ohmmeter?

Half Scale Resistance for Series Type Ohmmeter calculator uses Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance) to calculate the Half Scale Resistance, The Half Scale Resistance for Series Type Ohmmeter formula is defined as the resistance value that would produce a half-scale deflection of the meter when connected in series with the meter movement and the unknown resistance being measured. Half Scale Resistance is denoted by Rh symbol.

How to calculate Half Scale Resistance for Series Type Ohmmeter using this online calculator? To use this online calculator for Half Scale Resistance for Series Type Ohmmeter, enter Voltage Source (E), Zero Adjusting Resistance (R2), Current Full Scale Reading (If) & Meter Resistance (Rm) and hit the calculate button. Here is how the Half Scale Resistance for Series Type Ohmmeter calculation can be explained with given input values -> 65.64706 = (15.5*36)/(0.2*36+0.2*75).

FAQ

What is Half Scale Resistance for Series Type Ohmmeter?
The Half Scale Resistance for Series Type Ohmmeter formula is defined as the resistance value that would produce a half-scale deflection of the meter when connected in series with the meter movement and the unknown resistance being measured and is represented as Rh = (E*R2)/(If*R2+If*Rm) or Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance). Voltage Source refers to as a fundamental element that supplies electrical energy to a circuit, Zero Adjusting Resistance refers to a variable resistor used to calibrate or adjust the zero reading of a measuring instrument, Current Full Scale Reading represents the maximum current that the ohmmeter will pass through the resistor when it's being measured at its highest resistance value & Meter Resistance refers to the internal resistance of a measuring instrument. This resistance is inherent to the design of the instrument and affects the accuracy of measurements made by the device.
How to calculate Half Scale Resistance for Series Type Ohmmeter?
The Half Scale Resistance for Series Type Ohmmeter formula is defined as the resistance value that would produce a half-scale deflection of the meter when connected in series with the meter movement and the unknown resistance being measured is calculated using Half Scale Resistance = (Voltage Source*Zero Adjusting Resistance)/(Current Full Scale Reading*Zero Adjusting Resistance+Current Full Scale Reading*Meter Resistance). To calculate Half Scale Resistance for Series Type Ohmmeter, you need Voltage Source (E), Zero Adjusting Resistance (R2), Current Full Scale Reading (If) & Meter Resistance (Rm). With our tool, you need to enter the respective value for Voltage Source, Zero Adjusting Resistance, Current Full Scale Reading & Meter Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!