Group Refractive Index if Temperature and Humidity are different from Standard Values Solution

STEP 0: Pre-Calculation Summary
Formula Used
Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour)
n = 1+((0.269578*(n0-1)*Pb)/(273.15+t))-((11.27/(273.15+t))*10^-6*e)
This formula uses 5 Variables
Variables Used
Group Refractive Index - Group Refractive Index is the he ratio of the vacuum velocity of light to the group velocity in a medium.
Group Refractive Index for Standard Condition - Group Refractive Index for Standard Condition is the ratio of the vacuum velocity of light to the group velocity in a medium.
Barometric Pressure - Barometric Pressure is the pressure on earth that is caused by the weight of the air above us. It is sometimes the atmospheric pressure. It should be entered in millibar.
Temperature in Celsius - Temperature in Celsius is the degree of coolness or hotness of any substance. It should be entered in degree celsius.
Partial Pressure of Water Vapour - (Measured in Millibar) - Partial pressure of water vapour is the vapour pressure in any gas mixture in equilibrium with solid or liquid water.
STEP 1: Convert Input(s) to Base Unit
Group Refractive Index for Standard Condition: 1.2 --> No Conversion Required
Barometric Pressure: 6921.213 --> No Conversion Required
Temperature in Celsius: 98 --> No Conversion Required
Partial Pressure of Water Vapour: 1006 Millibar --> 1006 Millibar No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
n = 1+((0.269578*(n0-1)*Pb)/(273.15+t))-((11.27/(273.15+t))*10^-6*e) --> 1+((0.269578*(1.2-1)*6921.213)/(273.15+98))-((11.27/(273.15+98))*10^-6*1006)
Evaluating ... ...
n = 2.00538869460542
STEP 3: Convert Result to Output's Unit
2.00538869460542 --> No Conversion Required
FINAL ANSWER
2.00538869460542 2.005389 <-- Group Refractive Index
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

EDM Corrections Calculators

Group Refractive Index if Temperature and Humidity are different from Standard Values
​ LaTeX ​ Go Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour)
Group Refractive Index at Standard Conditions
​ LaTeX ​ Go Group Refractive Index for Standard Condition = 1+(287.604+(4.8864/Wavelength^2)+(0.068/Wavelength^4))*10^-6
Wave Velocity in Medium
​ LaTeX ​ Go Wave Velocity = Velocity in Vacuum/Refractive Index
Wave Velocity in Vacuum
​ LaTeX ​ Go Velocity in Vacuum = Wave Velocity*Refractive Index

Group Refractive Index if Temperature and Humidity are different from Standard Values Formula

​LaTeX ​Go
Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour)
n = 1+((0.269578*(n0-1)*Pb)/(273.15+t))-((11.27/(273.15+t))*10^-6*e)

How the Partial Pressure of Water Vapour is Calculated?

The value of e is determined from measurements of the difference in temperature
between the dry and wet bulb thermometer readings of td and tw respectively.

How to Calculate Group Refractive Index if Temperature and Humidity are different from Standard Values?

Group Refractive Index if Temperature and Humidity are different from Standard Values calculator uses Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour) to calculate the Group Refractive Index, The Group Refractive Index if Temperature and Humidity are different from Standard Values formula is defined as it defines the group refractive index values under different conditions from standard pressure and temperature. Group Refractive Index is denoted by n symbol.

How to calculate Group Refractive Index if Temperature and Humidity are different from Standard Values using this online calculator? To use this online calculator for Group Refractive Index if Temperature and Humidity are different from Standard Values, enter Group Refractive Index for Standard Condition (n0), Barometric Pressure (Pb), Temperature in Celsius (t) & Partial Pressure of Water Vapour (e) and hit the calculate button. Here is how the Group Refractive Index if Temperature and Humidity are different from Standard Values calculation can be explained with given input values -> 2.005389 = 1+((0.269578*(1.2-1)*6921.213)/(273.15+98))-((11.27/(273.15+98))*10^-6*100600).

FAQ

What is Group Refractive Index if Temperature and Humidity are different from Standard Values?
The Group Refractive Index if Temperature and Humidity are different from Standard Values formula is defined as it defines the group refractive index values under different conditions from standard pressure and temperature and is represented as n = 1+((0.269578*(n0-1)*Pb)/(273.15+t))-((11.27/(273.15+t))*10^-6*e) or Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour). Group Refractive Index for Standard Condition is the ratio of the vacuum velocity of light to the group velocity in a medium, Barometric Pressure is the pressure on earth that is caused by the weight of the air above us. It is sometimes the atmospheric pressure. It should be entered in millibar, Temperature in Celsius is the degree of coolness or hotness of any substance. It should be entered in degree celsius & Partial pressure of water vapour is the vapour pressure in any gas mixture in equilibrium with solid or liquid water.
How to calculate Group Refractive Index if Temperature and Humidity are different from Standard Values?
The Group Refractive Index if Temperature and Humidity are different from Standard Values formula is defined as it defines the group refractive index values under different conditions from standard pressure and temperature is calculated using Group Refractive Index = 1+((0.269578*(Group Refractive Index for Standard Condition-1)*Barometric Pressure)/(273.15+Temperature in Celsius))-((11.27/(273.15+Temperature in Celsius))*10^-6*Partial Pressure of Water Vapour). To calculate Group Refractive Index if Temperature and Humidity are different from Standard Values, you need Group Refractive Index for Standard Condition (n0), Barometric Pressure (Pb), Temperature in Celsius (t) & Partial Pressure of Water Vapour (e). With our tool, you need to enter the respective value for Group Refractive Index for Standard Condition, Barometric Pressure, Temperature in Celsius & Partial Pressure of Water Vapour and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Group Refractive Index?
In this formula, Group Refractive Index uses Group Refractive Index for Standard Condition, Barometric Pressure, Temperature in Celsius & Partial Pressure of Water Vapour. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Group Refractive Index = 1+(77.624*Barometric Pressure*10^-6/(273.15+Temperature in Celsius))+((0.372/(273.15+Temperature in Celsius)^2)-(12.92*10^-6/(273.15+Temperature in Celsius)))*Partial Pressure of Water Vapour
  • Group Refractive Index = 1+(0.000077624*Barometric Pressure/(273.15+Temperature in Celsius))-(((12.924/(273.15+Temperature in Celsius))+(371900/(273.15+Temperature in Celsius)^2))*10^-6*Partial Pressure of Water Vapour)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!