Ground Capacitance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance
Cgnd = ((Vagr*Cadj)/Vtm)-Cadj
This formula uses 4 Variables
Variables Used
Ground Capacitance - (Measured in Farad) - Ground Capacitance is the capacitance at the ground of the CMOS Circuit.
Agressor Voltage - (Measured in Volt) - Agressor Voltage refers to the avoided voltage in a CMOS circuit, which is typically a small positive voltage added to the input signal to avoid unwanted triggering of the circuit.
Adjacent Capacitance - (Measured in Farad) - Adjacent capacitance is the capacitance at adjacent point.
Victim Voltage - (Measured in Volt) - Victim Voltage is calculated when the victim being actively driven, then the driver will supply current to oppose to reduce the victim's noise.
STEP 1: Convert Input(s) to Base Unit
Agressor Voltage: 17.5 Volt --> 17.5 Volt No Conversion Required
Adjacent Capacitance: 8 Picofarad --> 8E-12 Farad (Check conversion ​here)
Victim Voltage: 12.75 Volt --> 12.75 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cgnd = ((Vagr*Cadj)/Vtm)-Cadj --> ((17.5*8E-12)/12.75)-8E-12
Evaluating ... ...
Cgnd = 2.98039215686275E-12
STEP 3: Convert Result to Output's Unit
2.98039215686275E-12 Farad -->2.98039215686275 Picofarad (Check conversion ​here)
FINAL ANSWER
2.98039215686275 2.980392 Picofarad <-- Ground Capacitance
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Array Datapath Subsystem Calculators

Ground Capacitance
​ LaTeX ​ Go Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance
'XOR' Delay
​ LaTeX ​ Go XOR Delay = Ripple Time-(Propagation Delay+(Gates on Critical Path-1)*AND-OR Gate Delay)
Carry-Ripple Adder Critical Path Delay
​ LaTeX ​ Go Ripple Time = Propagation Delay+(Gates on Critical Path-1)*AND-OR Gate Delay+XOR Delay
N-Bit Carry-Skip Adder
​ LaTeX ​ Go N-bit Carry Skip Adder = N-Input AND Gate*K-Input AND Gate

Ground Capacitance Formula

​LaTeX ​Go
Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance
Cgnd = ((Vagr*Cadj)/Vtm)-Cadj

How does noise vary with victim and the aggressor?

Suppose wire A switches while B is supposed to remain constant. This introduces noise as B partially switches. We call A the aggressor or perpetrator and B the victim(t). When the victim is floating, the noise remains indefinitely. When the victim is driven, the driver restores the victim. Larger (faster) drivers oppose the coupling sooner and result in noise that is a smaller percentage of the supply voltage. Note that during the noise event the victim transistor is in its linear region while the aggressor is in saturation. For equal-sized drivers, this means Raggressor is two to four times Rvictim, with greater ratios arising from more velocity saturation.

How to Calculate Ground Capacitance?

Ground Capacitance calculator uses Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance to calculate the Ground Capacitance, The Ground Capacitance formula is defined as the ratio of the amount of electric charge stored on a conductor to the difference in electric potential. Ground Capacitance is denoted by Cgnd symbol.

How to calculate Ground Capacitance using this online calculator? To use this online calculator for Ground Capacitance, enter Agressor Voltage (Vagr), Adjacent Capacitance (Cadj) & Victim Voltage (Vtm) and hit the calculate button. Here is how the Ground Capacitance calculation can be explained with given input values -> 3E+12 = ((17.5*8E-12)/12.75)-8E-12.

FAQ

What is Ground Capacitance?
The Ground Capacitance formula is defined as the ratio of the amount of electric charge stored on a conductor to the difference in electric potential and is represented as Cgnd = ((Vagr*Cadj)/Vtm)-Cadj or Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance. Agressor Voltage refers to the avoided voltage in a CMOS circuit, which is typically a small positive voltage added to the input signal to avoid unwanted triggering of the circuit, Adjacent capacitance is the capacitance at adjacent point & Victim Voltage is calculated when the victim being actively driven, then the driver will supply current to oppose to reduce the victim's noise.
How to calculate Ground Capacitance?
The Ground Capacitance formula is defined as the ratio of the amount of electric charge stored on a conductor to the difference in electric potential is calculated using Ground Capacitance = ((Agressor Voltage*Adjacent Capacitance)/Victim Voltage)-Adjacent Capacitance. To calculate Ground Capacitance, you need Agressor Voltage (Vagr), Adjacent Capacitance (Cadj) & Victim Voltage (Vtm). With our tool, you need to enter the respective value for Agressor Voltage, Adjacent Capacitance & Victim Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!