Gate Length using Gate Oxide Capacitance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Gate Length = Gate Capacitance/(Capacitance of Gate Oxide Layer*Gate Width)
Lg = Cg/(Cox*Wg)
This formula uses 4 Variables
Variables Used
Gate Length - (Measured in Meter) - Gate Length is the measurement or extent of something from end to end.
Gate Capacitance - (Measured in Farad) - Gate Capacitance is the capacitance of the gate terminal of a field-effect transistor.
Capacitance of Gate Oxide Layer - (Measured in Farad per Square Meter) - Capacitance of Gate Oxide Layer is defined as the capacitance of the gate terminal of a field-effect transistor.
Gate Width - (Measured in Meter) - Gate Width refers to the distance between the edge of a metal gate electrode and the adjacent semiconductor material in a CMOS.
STEP 1: Convert Input(s) to Base Unit
Gate Capacitance: 59.61 Microfarad --> 5.961E-05 Farad (Check conversion ​here)
Capacitance of Gate Oxide Layer: 29.83 Microfarad per Square Millimeter --> 29.83 Farad per Square Meter (Check conversion ​here)
Gate Width: 0.285 Millimeter --> 0.000285 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lg = Cg/(Cox*Wg) --> 5.961E-05/(29.83*0.000285)
Evaluating ... ...
Lg = 0.00701166257917674
STEP 3: Convert Result to Output's Unit
0.00701166257917674 Meter -->7.01166257917674 Millimeter (Check conversion ​here)
FINAL ANSWER
7.01166257917674 7.011663 Millimeter <-- Gate Length
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

VLSI Material Optimization Calculators

Body Effect Coefficient
​ LaTeX ​ Go Body Effect Coefficient = modulus((Threshold Voltage-Threshold Voltage DIBL)/(sqrt(Surface Potential+(Source Body Potential Difference))-sqrt(Surface Potential)))
DIBL Coefficient
​ LaTeX ​ Go DIBL Coefficient = (Threshold Voltage DIBL-Threshold Voltage)/Drain to Source Potential
Channel Charge
​ LaTeX ​ Go Channel Charge = Gate Capacitance*(Gate to Channel Voltage-Threshold Voltage)
Critical Voltage
​ LaTeX ​ Go Critical Voltage = Critical Electric Field*Electric Field Across Channel Length

Gate Length using Gate Oxide Capacitance Formula

​LaTeX ​Go
Gate Length = Gate Capacitance/(Capacitance of Gate Oxide Layer*Gate Width)
Lg = Cg/(Cox*Wg)

What are applications of Oxide Layer in VLSI?

The oxide layer in has key applications in semiconductor devices. It serves as a gate insulator in MOS transistors, enabling the control of electron flow. Additionally, it acts as an electrical isolation layer between different components and interconnects, ensuring reliable and efficient operation of integrated circuits in applications such as microprocessors, memory devices, and sensors.

How to Calculate Gate Length using Gate Oxide Capacitance?

Gate Length using Gate Oxide Capacitance calculator uses Gate Length = Gate Capacitance/(Capacitance of Gate Oxide Layer*Gate Width) to calculate the Gate Length, The Gate Length using gate Oxide Capacitance defined the path that links the charge carriers between the drain and the source. If you exclude the physical overlapping in the structure, gate length and channel length would be very close. Gate Length is denoted by Lg symbol.

How to calculate Gate Length using Gate Oxide Capacitance using this online calculator? To use this online calculator for Gate Length using Gate Oxide Capacitance, enter Gate Capacitance (Cg), Capacitance of Gate Oxide Layer (Cox) & Gate Width (Wg) and hit the calculate button. Here is how the Gate Length using Gate Oxide Capacitance calculation can be explained with given input values -> 6969.607 = 5.961E-05/(29.83*0.000285).

FAQ

What is Gate Length using Gate Oxide Capacitance?
The Gate Length using gate Oxide Capacitance defined the path that links the charge carriers between the drain and the source. If you exclude the physical overlapping in the structure, gate length and channel length would be very close and is represented as Lg = Cg/(Cox*Wg) or Gate Length = Gate Capacitance/(Capacitance of Gate Oxide Layer*Gate Width). Gate Capacitance is the capacitance of the gate terminal of a field-effect transistor, Capacitance of Gate Oxide Layer is defined as the capacitance of the gate terminal of a field-effect transistor & Gate Width refers to the distance between the edge of a metal gate electrode and the adjacent semiconductor material in a CMOS.
How to calculate Gate Length using Gate Oxide Capacitance?
The Gate Length using gate Oxide Capacitance defined the path that links the charge carriers between the drain and the source. If you exclude the physical overlapping in the structure, gate length and channel length would be very close is calculated using Gate Length = Gate Capacitance/(Capacitance of Gate Oxide Layer*Gate Width). To calculate Gate Length using Gate Oxide Capacitance, you need Gate Capacitance (Cg), Capacitance of Gate Oxide Layer (Cox) & Gate Width (Wg). With our tool, you need to enter the respective value for Gate Capacitance, Capacitance of Gate Oxide Layer & Gate Width and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!