Gap between Tool and Work Surface given Supply Current Solution

STEP 0: Pre-Calculation Summary
Formula Used
Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current)
h = A*Vs/(re*I)
This formula uses 5 Variables
Variables Used
Gap Between Tool And Work Surface - (Measured in Meter) - The Gap between Tool and Work Surface is the stretch of the distance between tool and work Surface during Electrochemical Machining.
Area of Penetration - (Measured in Square Meter) - Area of Penetration is area of penetration of electrons.
Supply Voltage - (Measured in Volt) - Supply Voltage is the voltage required to charge a given device within a given time.
Specific Resistance of The Electrolyte - (Measured in Ohm Meter) - Specific Resistance of The Electrolyte is the measure of how strongly it opposes the flow of current through them.
Electric Current - (Measured in Ampere) - Electric current is the rate of flow of electric charge through a circuit, measured in amperes.
STEP 1: Convert Input(s) to Base Unit
Area of Penetration: 7.6 Square Centimeter --> 0.00076 Square Meter (Check conversion ​here)
Supply Voltage: 9.869 Volt --> 9.869 Volt No Conversion Required
Specific Resistance of The Electrolyte: 3 Ohm Centimeter --> 0.03 Ohm Meter (Check conversion ​here)
Electric Current: 1000 Ampere --> 1000 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h = A*Vs/(re*I) --> 0.00076*9.869/(0.03*1000)
Evaluating ... ...
h = 0.000250014666666667
STEP 3: Convert Result to Output's Unit
0.000250014666666667 Meter -->0.250014666666667 Millimeter (Check conversion ​here)
FINAL ANSWER
0.250014666666667 0.250015 Millimeter <-- Gap Between Tool And Work Surface
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Kumar Siddhant
Indian Institute of Information Technology, Design and Manufacturing (IIITDM), Jabalpur
Kumar Siddhant has created this Calculator and 400+ more calculators!
Verifier Image
Verified by Parul Keshav
National Institute of Technology (NIT), Srinagar
Parul Keshav has verified this Calculator and 400+ more calculators!

Gap Resistance Calculators

Density of Work Material given Gap between Tool and Work Surface
​ LaTeX ​ Go Work Piece Density = Current Efficiency in Decimal*Supply Voltage*Electrochemical Equivalent/(Specific Resistance of The Electrolyte*Feed Speed*Gap Between Tool And Work Surface)
Gap between Tool and Work Surface
​ LaTeX ​ Go Gap Between Tool And Work Surface = Current Efficiency in Decimal*Supply Voltage*Electrochemical Equivalent/(Specific Resistance of The Electrolyte*Work Piece Density*Feed Speed)
Specific Resistivity of Electrolyte given Supply Current
​ LaTeX ​ Go Specific Resistance of The Electrolyte = Area of Penetration*Supply Voltage/(Gap Between Tool And Work Surface*Electric Current)
Gap between Tool and Work Surface given Supply Current
​ LaTeX ​ Go Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current)

Gap between Tool and Work Surface given Supply Current Formula

​LaTeX ​Go
Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current)
h = A*Vs/(re*I)

Tools for ECM

Tools for ECM are made from material chemically resistant to t the electrolyte and also relatively easy to machine. Commonly used materials are brass, copper, stainless steel, and titanium. Tool design is often based upon experience with the process.
A most important factor in the ECM tool design is the provision of a suitable passage through the tool for efficient electrolyte flow through the cutting gap and to prevent stagnation areas.

How to Calculate Gap between Tool and Work Surface given Supply Current?

Gap between Tool and Work Surface given Supply Current calculator uses Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current) to calculate the Gap Between Tool And Work Surface, The Gap between Tool and Work Surface given Supply Current is a method to determine the maximum allowed the gap between the tool and the work surface for a required Volumetric Flow Rate when the Current Supplied is fixed. Gap Between Tool And Work Surface is denoted by h symbol.

How to calculate Gap between Tool and Work Surface given Supply Current using this online calculator? To use this online calculator for Gap between Tool and Work Surface given Supply Current, enter Area of Penetration (A), Supply Voltage (Vs), Specific Resistance of The Electrolyte (re) & Electric Current (I) and hit the calculate button. Here is how the Gap between Tool and Work Surface given Supply Current calculation can be explained with given input values -> 250.04 = 0.00076*9.869/(0.03*1000).

FAQ

What is Gap between Tool and Work Surface given Supply Current?
The Gap between Tool and Work Surface given Supply Current is a method to determine the maximum allowed the gap between the tool and the work surface for a required Volumetric Flow Rate when the Current Supplied is fixed and is represented as h = A*Vs/(re*I) or Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current). Area of Penetration is area of penetration of electrons, Supply Voltage is the voltage required to charge a given device within a given time, Specific Resistance of The Electrolyte is the measure of how strongly it opposes the flow of current through them & Electric current is the rate of flow of electric charge through a circuit, measured in amperes.
How to calculate Gap between Tool and Work Surface given Supply Current?
The Gap between Tool and Work Surface given Supply Current is a method to determine the maximum allowed the gap between the tool and the work surface for a required Volumetric Flow Rate when the Current Supplied is fixed is calculated using Gap Between Tool And Work Surface = Area of Penetration*Supply Voltage/(Specific Resistance of The Electrolyte*Electric Current). To calculate Gap between Tool and Work Surface given Supply Current, you need Area of Penetration (A), Supply Voltage (Vs), Specific Resistance of The Electrolyte (re) & Electric Current (I). With our tool, you need to enter the respective value for Area of Penetration, Supply Voltage, Specific Resistance of The Electrolyte & Electric Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Gap Between Tool And Work Surface?
In this formula, Gap Between Tool And Work Surface uses Area of Penetration, Supply Voltage, Specific Resistance of The Electrolyte & Electric Current. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Gap Between Tool And Work Surface = Current Efficiency in Decimal*Supply Voltage*Electrochemical Equivalent/(Specific Resistance of The Electrolyte*Work Piece Density*Feed Speed)
  • Gap Between Tool And Work Surface = (Resistance of Gap Between Work And Tool*Cross Sectional Area of Gap)/Specific Resistance of The Electrolyte
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!