Full Load Speed of Shunt DC Motor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Full Load Speed = (100*No Load Speed)/(Speed Regulation+100)
Nfl = (100*Nnl)/(Nreg+100)
This formula uses 3 Variables
Variables Used
Full Load Speed - (Measured in Radian per Second) - Full Load Speed is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load.
No Load Speed - (Measured in Radian per Second) - No Load Speed is defined as a reference to how fast the shaft of a motor will turn before weight is added to it.
Speed Regulation - (Measured in Radian per Second) - Speed Regulation is the change in speed from no load to full load, expressed as a fraction or percentage of full load speed.
STEP 1: Convert Input(s) to Base Unit
No Load Speed: 2.58 Revolution per Minute --> 0.270176968194964 Radian per Second (Check conversion ​here)
Speed Regulation: 12012 Revolution per Minute --> 1257.8936984333 Radian per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Nfl = (100*Nnl)/(Nreg+100) --> (100*0.270176968194964)/(1257.8936984333+100)
Evaluating ... ...
Nfl = 0.0198967686871724
STEP 3: Convert Result to Output's Unit
0.0198967686871724 Radian per Second -->0.190000145296847 Revolution per Minute (Check conversion ​here)
FINAL ANSWER
0.190000145296847 0.19 Revolution per Minute <-- Full Load Speed
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

Speed Calculators

Angular Speed of DC Shunt Motor given Kf
​ LaTeX ​ Go Angular Speed = Back EMF/(Constant of Machine Construction*Magnetic Flux)
Speed Regulation of Shunt DC Motor
​ LaTeX ​ Go Speed Regulation = ((No Load Speed-Full Load Speed)/Full Load Speed)*100
No Load Speed of Shunt DC Motor
​ LaTeX ​ Go No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed)
Angular Speed of DC Shunt Motor given Output Power
​ LaTeX ​ Go Angular Speed = Output Power/Torque

Full Load Speed of Shunt DC Motor Formula

​LaTeX ​Go
Full Load Speed = (100*No Load Speed)/(Speed Regulation+100)
Nfl = (100*Nnl)/(Nreg+100)

Is the speed of DC shunt motor variable?

By varying flux, we can increase the speed more than its base speed. This method is constant power and variable torque drive. Explanation: For a DC shunt motor, speed cannot be varied by the method of starting.

How to Calculate Full Load Speed of Shunt DC Motor?

Full Load Speed of Shunt DC Motor calculator uses Full Load Speed = (100*No Load Speed)/(Speed Regulation+100) to calculate the Full Load Speed, The Full Load Speed of Shunt DC Motor formula is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load. Full Load Speed is denoted by Nfl symbol.

How to calculate Full Load Speed of Shunt DC Motor using this online calculator? To use this online calculator for Full Load Speed of Shunt DC Motor, enter No Load Speed (Nnl) & Speed Regulation (Nreg) and hit the calculate button. Here is how the Full Load Speed of Shunt DC Motor calculation can be explained with given input values -> 1.68386 = (100*0.270176968194964)/(1257.8936984333+100).

FAQ

What is Full Load Speed of Shunt DC Motor?
The Full Load Speed of Shunt DC Motor formula is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load and is represented as Nfl = (100*Nnl)/(Nreg+100) or Full Load Speed = (100*No Load Speed)/(Speed Regulation+100). No Load Speed is defined as a reference to how fast the shaft of a motor will turn before weight is added to it & Speed Regulation is the change in speed from no load to full load, expressed as a fraction or percentage of full load speed.
How to calculate Full Load Speed of Shunt DC Motor?
The Full Load Speed of Shunt DC Motor formula is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load is calculated using Full Load Speed = (100*No Load Speed)/(Speed Regulation+100). To calculate Full Load Speed of Shunt DC Motor, you need No Load Speed (Nnl) & Speed Regulation (Nreg). With our tool, you need to enter the respective value for No Load Speed & Speed Regulation and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!