Full flow velocity in sewer Solution

STEP 0: Pre-Calculation Summary
Formula Used
Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface
Vf = (0.59*di^(2/3)*S^(1/2))/nc
This formula uses 4 Variables
Variables Used
Flow Velocity - (Measured in Meter per Second) - The Flow Velocity refers to the speed at which a fluid (such as water) moves through a specific cross-section.
Inner Diameter - (Measured in Meter) - The Inner Diameter refers to the diameter of the inner surface or bore of a cylindrical object or conduit.
Energy Loss - (Measured in Joule) - The Energy Loss refers to the dissipation or reduction of energy within a system or process.
Roughness Coefficient of Conduit Surface - The Roughness Coefficient of Conduit Surface refers to the roughness or irregularity of the inner surface of a conduit through which fluid flows.
STEP 1: Convert Input(s) to Base Unit
Inner Diameter: 35 Meter --> 35 Meter No Conversion Required
Energy Loss: 2 Joule --> 2 Joule No Conversion Required
Roughness Coefficient of Conduit Surface: 0.017 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vf = (0.59*di^(2/3)*S^(1/2))/nc --> (0.59*35^(2/3)*2^(1/2))/0.017
Evaluating ... ...
Vf = 525.166221108757
STEP 3: Convert Result to Output's Unit
525.166221108757 Meter per Second --> No Conversion Required
FINAL ANSWER
525.166221108757 525.1662 Meter per Second <-- Flow Velocity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

Required Flow Velocity Calculators

Inside Diameter given Full Flow Velocity in Sewer
​ LaTeX ​ Go Inner Diameter = ((Flow Velocity*Roughness Coefficient of Conduit Surface)/(0.59*Energy Loss^(1/2)))^(3/2)
Coefficient of Roughness given Full Flow Velocity in Sewer
​ LaTeX ​ Go Roughness Coefficient of Conduit Surface = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Flow Velocity
Energy Loss given Full Flow Velocity in Sewer
​ LaTeX ​ Go Energy Loss = ((Flow Velocity*Roughness Coefficient of Conduit Surface)/(0.59*Inner Diameter^(2/3)))^2
Full flow velocity in sewer
​ LaTeX ​ Go Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface

Full flow velocity in sewer Formula

​LaTeX ​Go
Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface
Vf = (0.59*di^(2/3)*S^(1/2))/nc

What is the difference between flow rate and velocity?

Rate of flow, or simply flow, is the quantity of water, for example, that flows in a tube or other medium, in an interval of time. Examples: 2 kg of water per second, or 100 cubric meters of air per minute. Velocity is how fast the water, air or other fluid is moving in a tube or other medium.

How to Calculate Full flow velocity in sewer?

Full flow velocity in sewer calculator uses Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface to calculate the Flow Velocity, The Full flow velocity in sewer calculates the flow velocity in sewer when we have a prior info of the roughness coefficient, inner diameter of the pipe and energy loss due to the roughness of the surface. Flow Velocity is denoted by Vf symbol.

How to calculate Full flow velocity in sewer using this online calculator? To use this online calculator for Full flow velocity in sewer, enter Inner Diameter (di), Energy Loss (S) & Roughness Coefficient of Conduit Surface (nc) and hit the calculate button. Here is how the Full flow velocity in sewer calculation can be explained with given input values -> 525.1662 = (0.59*35^(2/3)*2^(1/2))/0.017.

FAQ

What is Full flow velocity in sewer?
The Full flow velocity in sewer calculates the flow velocity in sewer when we have a prior info of the roughness coefficient, inner diameter of the pipe and energy loss due to the roughness of the surface and is represented as Vf = (0.59*di^(2/3)*S^(1/2))/nc or Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface. The Inner Diameter refers to the diameter of the inner surface or bore of a cylindrical object or conduit, The Energy Loss refers to the dissipation or reduction of energy within a system or process & The Roughness Coefficient of Conduit Surface refers to the roughness or irregularity of the inner surface of a conduit through which fluid flows.
How to calculate Full flow velocity in sewer?
The Full flow velocity in sewer calculates the flow velocity in sewer when we have a prior info of the roughness coefficient, inner diameter of the pipe and energy loss due to the roughness of the surface is calculated using Flow Velocity = (0.59*Inner Diameter^(2/3)*Energy Loss^(1/2))/Roughness Coefficient of Conduit Surface. To calculate Full flow velocity in sewer, you need Inner Diameter (di), Energy Loss (S) & Roughness Coefficient of Conduit Surface (nc). With our tool, you need to enter the respective value for Inner Diameter, Energy Loss & Roughness Coefficient of Conduit Surface and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!