Francis Formula for Discharge for Rectangular Notch if Velocity not considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2)
QFr = 1.84*(Lw-0.1*n*Sw)*Sw^(3/2)
This formula uses 4 Variables
Variables Used
Francis Discharge - (Measured in Cubic Meter per Second) - Francis Discharge is calculated from the empirical formula given by Francis.
Length of Weir Crest - (Measured in Meter) - Length of Weir Crest is the measurement or extent of Weir Crest from end to end.
Number of End Contraction - Number of End Contraction 1 can be described as the end contractions acting on a channel.
Height of Water above Crest of Weir - (Measured in Meter) - Height of Water above Crest of Weir is defined as the water surface height above crest.
STEP 1: Convert Input(s) to Base Unit
Length of Weir Crest: 3 Meter --> 3 Meter No Conversion Required
Number of End Contraction: 4 --> No Conversion Required
Height of Water above Crest of Weir: 2 Meter --> 2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
QFr = 1.84*(Lw-0.1*n*Sw)*Sw^(3/2) --> 1.84*(3-0.1*4*2)*2^(3/2)
Evaluating ... ...
QFr = 11.4494730009726
STEP 3: Convert Result to Output's Unit
11.4494730009726 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
11.4494730009726 11.44947 Cubic Meter per Second <-- Francis Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

Flow Over Rectangular Sharp Crested Weir or Notch Calculators

Coefficient of Discharge given Discharge if Velocity considered
​ LaTeX ​ Go Coefficient of Discharge = (Francis Discharge*3)/(2*(sqrt(2*Acceleration due to Gravity))*(Length of Weir Crest-0.1*Number of End Contraction*Still Water Head)*(Still Water Head^(3/2)-Velocity Head^(3/2)))
Coefficient of Discharge given Discharge if Velocity not considered
​ LaTeX ​ Go Coefficient of Discharge = (Francis Discharge*3)/(2*(sqrt(2*Acceleration due to Gravity))*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2))
Coefficient of Discharge given Discharge Passing over Weir considering Velocity
​ LaTeX ​ Go Coefficient of Discharge = (Francis Discharge with Suppressed End*3)/(2*(sqrt(2*Acceleration due to Gravity))*Length of Weir Crest*((Height of Water above Crest of Weir+Velocity Head)^(3/2)-Velocity Head^(3/2)))
Coefficient of Discharge given Discharge over Weir without considering Velocity
​ LaTeX ​ Go Coefficient of Discharge = (Francis Discharge with Suppressed End*3)/(2*(sqrt(2*Acceleration due to Gravity))*Length of Weir Crest*Height of Water above Crest of Weir^(3/2))

Francis Formula for Discharge for Rectangular Notch if Velocity not considered Formula

​LaTeX ​Go
Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2)
QFr = 1.84*(Lw-0.1*n*Sw)*Sw^(3/2)

What is meant by Head?

In hydraulics, Head is a measure of the potential of fluid at the measurement point. or total energy per unit weight above a datum.

What is the use of triangular notch?

The triangular-notch, thin-plate weir is a convenient, inexpensive, and relatively precise flow-measuring instrument. It is frequently used to measure the flow of water in laboratories and in small, natural streams.

How to Calculate Francis Formula for Discharge for Rectangular Notch if Velocity not considered?

Francis Formula for Discharge for Rectangular Notch if Velocity not considered calculator uses Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2) to calculate the Francis Discharge, The Francis formula for discharge for rectangular notch if velocity not considered is a measure of the quantity of any fluid flow over unit time. The quantity may be either volume or mass. Francis Discharge is denoted by QFr symbol.

How to calculate Francis Formula for Discharge for Rectangular Notch if Velocity not considered using this online calculator? To use this online calculator for Francis Formula for Discharge for Rectangular Notch if Velocity not considered, enter Length of Weir Crest (Lw), Number of End Contraction (n) & Height of Water above Crest of Weir (Sw) and hit the calculate button. Here is how the Francis Formula for Discharge for Rectangular Notch if Velocity not considered calculation can be explained with given input values -> 11.44947 = 1.84*(3-0.1*4*2)*2^(3/2).

FAQ

What is Francis Formula for Discharge for Rectangular Notch if Velocity not considered?
The Francis formula for discharge for rectangular notch if velocity not considered is a measure of the quantity of any fluid flow over unit time. The quantity may be either volume or mass and is represented as QFr = 1.84*(Lw-0.1*n*Sw)*Sw^(3/2) or Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2). Length of Weir Crest is the measurement or extent of Weir Crest from end to end, Number of End Contraction 1 can be described as the end contractions acting on a channel & Height of Water above Crest of Weir is defined as the water surface height above crest.
How to calculate Francis Formula for Discharge for Rectangular Notch if Velocity not considered?
The Francis formula for discharge for rectangular notch if velocity not considered is a measure of the quantity of any fluid flow over unit time. The quantity may be either volume or mass is calculated using Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Height of Water above Crest of Weir)*Height of Water above Crest of Weir^(3/2). To calculate Francis Formula for Discharge for Rectangular Notch if Velocity not considered, you need Length of Weir Crest (Lw), Number of End Contraction (n) & Height of Water above Crest of Weir (Sw). With our tool, you need to enter the respective value for Length of Weir Crest, Number of End Contraction & Height of Water above Crest of Weir and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Francis Discharge?
In this formula, Francis Discharge uses Length of Weir Crest, Number of End Contraction & Height of Water above Crest of Weir. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Francis Discharge = 1.84*(Length of Weir Crest-0.1*Number of End Contraction*Still Water Head)*(Still Water Head^(3/2)-Velocity Head^(3/2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!