Formation Constant T given Change in Drawdown Solution

STEP 0: Pre-Calculation Summary
Formula Used
Formation Constant T given Change in Drawdown = (2.303*Discharge)/(4*pi*Change in Drawdown)
FT = (2.303*Q)/(4*pi*Δd)
This formula uses 1 Constants, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Formation Constant T given Change in Drawdown - (Measured in Square Meter per Second) - Formation Constant T given Change in Drawdown is defined as the difference at the two wells.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a fluid in unsteady flow.
Change in Drawdown - (Measured in Meter) - Change in Drawdown is defined as the difference at the two wells.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Change in Drawdown: 0.23 Meter --> 0.23 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
FT = (2.303*Q)/(4*pi*Δd) --> (2.303*1.01)/(4*pi*0.23)
Evaluating ... ...
FT = 0.804780809304438
STEP 3: Convert Result to Output's Unit
0.804780809304438 Square Meter per Second --> No Conversion Required
FINAL ANSWER
0.804780809304438 0.804781 Square Meter per Second <-- Formation Constant T given Change in Drawdown
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Formation Constant Calculators

Constant dependent on Well Function given Formation Constant S
​ LaTeX ​ Go Well Function Constant = Formation Constant for Unsteady Flow/((4*Formation Constant T*Time in Days)/(Radial Distance)^2)
Formation Constant T given Formation Constant S
​ LaTeX ​ Go Formation Constant T = Formation Constant for Unsteady Flow/((4*Well Function Constant*Time in Days)/(Radial Distance)^2)
Formation Constant S
​ LaTeX ​ Go Formation Constant for Unsteady Flow = (4*Well Function Constant*Formation Constant T*Time in Days)/(Radial Distance)^2
Formation Constant given Drawdown
​ LaTeX ​ Go Formation Constant for Unsteady Flow = (Discharge*Well Function of u)/(4*pi*Total Drawdown in Well)

Formation Constant T given Change in Drawdown Formula

​LaTeX ​Go
Formation Constant T given Change in Drawdown = (2.303*Discharge)/(4*pi*Change in Drawdown)
FT = (2.303*Q)/(4*pi*Δd)

What is Formation Constant?

A stability constant (formation constant, binding constant) is an equilibrium constant for the formation of a complex in solution. It is a measure of the strength of the interaction between the reagents that come together to form the complex.

How to Calculate Formation Constant T given Change in Drawdown?

Formation Constant T given Change in Drawdown calculator uses Formation Constant T given Change in Drawdown = (2.303*Discharge)/(4*pi*Change in Drawdown) to calculate the Formation Constant T given Change in Drawdown, Formation Constant T given Change in Drawdown formula is defined as a measure of the change in drawdown of a well in unsteady flow conditions, which is essential in understanding the behavior of groundwater flow in aquifers and is used to analyze the response of a well to changes in pumping rates or other external factors. Formation Constant T given Change in Drawdown is denoted by FT symbol.

How to calculate Formation Constant T given Change in Drawdown using this online calculator? To use this online calculator for Formation Constant T given Change in Drawdown, enter Discharge (Q) & Change in Drawdown (Δd) and hit the calculate button. Here is how the Formation Constant T given Change in Drawdown calculation can be explained with given input values -> 0.804781 = (2.303*1.01)/(4*pi*0.23).

FAQ

What is Formation Constant T given Change in Drawdown?
Formation Constant T given Change in Drawdown formula is defined as a measure of the change in drawdown of a well in unsteady flow conditions, which is essential in understanding the behavior of groundwater flow in aquifers and is used to analyze the response of a well to changes in pumping rates or other external factors and is represented as FT = (2.303*Q)/(4*pi*Δd) or Formation Constant T given Change in Drawdown = (2.303*Discharge)/(4*pi*Change in Drawdown). Discharge is the rate of flow of a fluid in unsteady flow & Change in Drawdown is defined as the difference at the two wells.
How to calculate Formation Constant T given Change in Drawdown?
Formation Constant T given Change in Drawdown formula is defined as a measure of the change in drawdown of a well in unsteady flow conditions, which is essential in understanding the behavior of groundwater flow in aquifers and is used to analyze the response of a well to changes in pumping rates or other external factors is calculated using Formation Constant T given Change in Drawdown = (2.303*Discharge)/(4*pi*Change in Drawdown). To calculate Formation Constant T given Change in Drawdown, you need Discharge (Q) & Change in Drawdown (Δd). With our tool, you need to enter the respective value for Discharge & Change in Drawdown and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!