Fluoroscence Intensity without Quenching Solution

STEP 0: Pre-Calculation Summary
Formula Used
Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence)
I_o = (Kf*Ia)/(KNR+Kf)
This formula uses 4 Variables
Variables Used
Intensity Without Quenching - (Measured in Watt per Square Meter) - Intensity Without Quenching is the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy.
Rate Constant of Fluoroscence - (Measured in Hertz) - Rate Constant of Fluoroscence is the rate at which spontaneous emission occurs.
Absorption Intensity - (Measured in Watt per Square Meter) - Absorption Intensity obtained by integrating the area under the absorption line—is proportional to the amount of the absorbing substance present.
Rate Constant of Non Radiative Reaction - (Measured in Hertz) - Rate Constant of Non Radiative Reaction is defined as the rate at which deactivation occurs in the form of heat energy.
STEP 1: Convert Input(s) to Base Unit
Rate Constant of Fluoroscence: 750 Revolution per Second --> 750 Hertz (Check conversion ​here)
Absorption Intensity: 250 Watt per Square Meter --> 250 Watt per Square Meter No Conversion Required
Rate Constant of Non Radiative Reaction: 35 Revolution per Second --> 35 Hertz (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
I_o = (Kf*Ia)/(KNR+Kf) --> (750*250)/(35+750)
Evaluating ... ...
I_o = 238.853503184713
STEP 3: Convert Result to Output's Unit
238.853503184713 Watt per Square Meter --> No Conversion Required
FINAL ANSWER
238.853503184713 238.8535 Watt per Square Meter <-- Intensity Without Quenching
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Torsha_Paul
University of Calcutta (CU), Kolkata
Torsha_Paul has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 900+ more calculators!

Emission Spectroscopy Calculators

Degree of Exciplex Formation
​ LaTeX ​ Go Degree of Exciplex Formation = (Equilibrium Constant for Coordinate Complexes*Quencher Concentration given Degree of Exciplex)/(1+(Equilibrium Constant for Coordinate Complexes*Quencher Concentration given Degree of Exciplex))
Collisional Energy Transfer
​ LaTeX ​ Go Rate of Collisional Energy Transfer = Quenching Constant*Quencher Concentration given Degree of Exciplex*Singlet State Concentration
Difference in Acidity between Ground and Excited State
​ LaTeX ​ Go Difference in pka = pKa of Excited State-pKa of Ground State
Equilibrium Constant for Exciplex Formation
​ LaTeX ​ Go Equilibrium Constant for Coordinate Complexes = 1/(1-Degree of Exciplex Formation)-1

Fluoroscence and Phosphorescence Calculators

Initial Intensity given Degree of Exciplex Formation
​ LaTeX ​ Go Initial Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Fluoroscence Intensity without Quenching
​ LaTeX ​ Go Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence)
Fluoroscence Intensity
​ LaTeX ​ Go Fluorosence Intensity = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Fluorescence Rate Constant
​ LaTeX ​ Go Rate Constant of Fluoroscence = Rate of Fluoroscence/Singlet State Concentration

Fluoroscence Intensity without Quenching Formula

​LaTeX ​Go
Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence)
I_o = (Kf*Ia)/(KNR+Kf)

What is Fluorescence Quenching ?

Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular interactions can result in quenching.

How to Calculate Fluoroscence Intensity without Quenching?

Fluoroscence Intensity without Quenching calculator uses Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence) to calculate the Intensity Without Quenching, The Fluoroscence Intensity without Quenching formula is defined as the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy. Intensity Without Quenching is denoted by I_o symbol.

How to calculate Fluoroscence Intensity without Quenching using this online calculator? To use this online calculator for Fluoroscence Intensity without Quenching, enter Rate Constant of Fluoroscence (Kf), Absorption Intensity (Ia) & Rate Constant of Non Radiative Reaction (KNR) and hit the calculate button. Here is how the Fluoroscence Intensity without Quenching calculation can be explained with given input values -> 238.8535 = (750*250)/(35+750).

FAQ

What is Fluoroscence Intensity without Quenching?
The Fluoroscence Intensity without Quenching formula is defined as the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy and is represented as I_o = (Kf*Ia)/(KNR+Kf) or Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence). Rate Constant of Fluoroscence is the rate at which spontaneous emission occurs, Absorption Intensity obtained by integrating the area under the absorption line—is proportional to the amount of the absorbing substance present & Rate Constant of Non Radiative Reaction is defined as the rate at which deactivation occurs in the form of heat energy.
How to calculate Fluoroscence Intensity without Quenching?
The Fluoroscence Intensity without Quenching formula is defined as the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy is calculated using Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence). To calculate Fluoroscence Intensity without Quenching, you need Rate Constant of Fluoroscence (Kf), Absorption Intensity (Ia) & Rate Constant of Non Radiative Reaction (KNR). With our tool, you need to enter the respective value for Rate Constant of Fluoroscence, Absorption Intensity & Rate Constant of Non Radiative Reaction and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!