Flow Rate given Power in Kilowatt Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge from Dam = (Hydroelectric Power*11.8)/(Efficiency of Turbine*Effective Head)
Qt = (P*11.8)/(η*H)
This formula uses 4 Variables
Variables Used
Discharge from Dam - (Measured in Cubic Meter per Second) - Discharge from Dam is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Hydroelectric Power - (Measured in Watt) - Hydroelectric Power is electricity generated by the flow of water through turbines, harnessing the energy of falling or flowing water.
Efficiency of Turbine - The Efficiency of Turbine refers to the ability of a turbine to convert input energy into useful output power with minimal losses.
Effective Head - (Measured in Meter) - Effective Head can be described as the actual vertical drop minus this head loss.
STEP 1: Convert Input(s) to Base Unit
Hydroelectric Power: 170 Watt --> 170 Watt No Conversion Required
Efficiency of Turbine: 14 --> No Conversion Required
Effective Head: 232.2 Meter --> 232.2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qt = (P*11.8)/(η*H) --> (170*11.8)/(14*232.2)
Evaluating ... ...
Qt = 0.617078872892826
STEP 3: Convert Result to Output's Unit
0.617078872892826 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.617078872892826 0.617079 Cubic Meter per Second <-- Discharge from Dam
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has created this Calculator and 1300+ more calculators!
Verifier Image
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

Hydroelectric Power Generation Calculators

Flow Rate given Power obtained from Water Flow in Horsepower
​ LaTeX ​ Go Flow rate = (Hydroelectric Power*550)/(Efficiency of Turbine*Effective Head*Unit Weight of Water)
Flow Rate for Power obtained from Water Flow in Horsepower
​ LaTeX ​ Go Discharge from Dam = (Hydroelectric Power*8.8)/(Efficiency of Turbine*Effective Head)
Total Weight of Water given Potential Energy in Hydroelectric Power Generation
​ LaTeX ​ Go Unit Weight of Water = Potential Energy/Vertical Distance Water can Fall
Potential Energy of Volume of Water in Hydroelectric Power Generation
​ LaTeX ​ Go Potential Energy = Unit Weight of Water*Vertical Distance Water can Fall

Flow Rate given Power in Kilowatt Formula

​LaTeX ​Go
Discharge from Dam = (Hydroelectric Power*11.8)/(Efficiency of Turbine*Effective Head)
Qt = (P*11.8)/(η*H)

What is Hydro-Electric Power?

Hydro power is electrical energy produced through the power of moving water. Power obtained from the (typically gravitational) movement of water., Hydropower plants derive energy from the force of moving water and harness this energy for useful purposes.

How to Calculate Flow Rate given Power in Kilowatt?

Flow Rate given Power in Kilowatt calculator uses Discharge from Dam = (Hydroelectric Power*11.8)/(Efficiency of Turbine*Effective Head) to calculate the Discharge from Dam, The Flow rate given Power in Kilowatt is defined as rate at which water is flowing in the channels. Discharge from Dam is denoted by Qt symbol.

How to calculate Flow Rate given Power in Kilowatt using this online calculator? To use this online calculator for Flow Rate given Power in Kilowatt, enter Hydroelectric Power (P), Efficiency of Turbine (η) & Effective Head (H) and hit the calculate button. Here is how the Flow Rate given Power in Kilowatt calculation can be explained with given input values -> 0.955238 = (170*11.8)/(14*232.2).

FAQ

What is Flow Rate given Power in Kilowatt?
The Flow rate given Power in Kilowatt is defined as rate at which water is flowing in the channels and is represented as Qt = (P*11.8)/(η*H) or Discharge from Dam = (Hydroelectric Power*11.8)/(Efficiency of Turbine*Effective Head). Hydroelectric Power is electricity generated by the flow of water through turbines, harnessing the energy of falling or flowing water, The Efficiency of Turbine refers to the ability of a turbine to convert input energy into useful output power with minimal losses & Effective Head can be described as the actual vertical drop minus this head loss.
How to calculate Flow Rate given Power in Kilowatt?
The Flow rate given Power in Kilowatt is defined as rate at which water is flowing in the channels is calculated using Discharge from Dam = (Hydroelectric Power*11.8)/(Efficiency of Turbine*Effective Head). To calculate Flow Rate given Power in Kilowatt, you need Hydroelectric Power (P), Efficiency of Turbine (η) & Effective Head (H). With our tool, you need to enter the respective value for Hydroelectric Power, Efficiency of Turbine & Effective Head and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge from Dam?
In this formula, Discharge from Dam uses Hydroelectric Power, Efficiency of Turbine & Effective Head. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Discharge from Dam = (Hydroelectric Power*8.8)/(Efficiency of Turbine*Effective Head)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!