Filter Volume given Volume of Raw Sewage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volumetric Flow Rate = (Total Organic Load*Volume of Raw Sewage)/(Volume of Recirculated Sewage*Organic Loading)
V = (Y*I)/(R*VL)
This formula uses 5 Variables
Variables Used
Volumetric Flow Rate - (Measured in Cubic Meter per Second) - Volumetric Flow Rate referred as a measure of the volume of fluid that flows through a given surface per unit time.
Total Organic Load - (Measured in Kilogram per Second) - Total organic load is the total amount of organic material present in a water or wastewater sample.
Volume of Raw Sewage - (Measured in Cubic Meter) - Volume of raw sewage means the volume of sewage generated recently.
Volume of Recirculated Sewage - (Measured in Cubic Meter) - Volume of Recirculated Sewage means the volume of sewage after the recirculation.
Organic Loading - (Measured in Kilogram per Cubic Meter) - Organic Loading is defined as the application of soluble and particulate organic matter.
STEP 1: Convert Input(s) to Base Unit
Total Organic Load: 80 Kilogram per Day --> 0.000925925925925926 Kilogram per Second (Check conversion ​here)
Volume of Raw Sewage: 20 Cubic Meter --> 20 Cubic Meter No Conversion Required
Volume of Recirculated Sewage: 3 Cubic Meter --> 3 Cubic Meter No Conversion Required
Organic Loading: 1.31 Milligram per Liter --> 0.00131 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = (Y*I)/(R*VL) --> (0.000925925925925926*20)/(3*0.00131)
Evaluating ... ...
V = 4.71209122608614
STEP 3: Convert Result to Output's Unit
4.71209122608614 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
4.71209122608614 4.712091 Cubic Meter per Second <-- Volumetric Flow Rate
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Efficiency of High Rate Filters Calculators

Recirculation Factor given Volume of Raw Sewage
​ LaTeX ​ Go Recirculation Factor = (1+(Volume of Recirculated Sewage/Volume of Raw Sewage))/(1+0.1*(Volume of Recirculated Sewage/Volume of Raw Sewage))^2
Recirculation Factor given Recirculation Ratio
​ LaTeX ​ Go Recirculation Factor = (1+Recirculation Ratio)/(1+0.1*Recirculation Ratio)^2
Recirculation Ratio given Volume of Raw Sewage
​ LaTeX ​ Go Recirculation Ratio = Volume of Recirculated Sewage/Volume of Raw Sewage
Volume of Raw Sewage given Recirculation Ratio
​ LaTeX ​ Go Volume of Raw Sewage = Volume of Recirculated Sewage/Recirculation Ratio

Filter Volume given Volume of Raw Sewage Formula

​LaTeX ​Go
Volumetric Flow Rate = (Total Organic Load*Volume of Raw Sewage)/(Volume of Recirculated Sewage*Organic Loading)
V = (Y*I)/(R*VL)

What is Organic Loading?

Organic loading rate is defined as the application of soluble and particulate organic matter. It is typically expressed on an area basis as pounds of BOD5 per unit area per unit time, such as pounds of BOD5 per square foot per day.

How to Calculate Filter Volume given Volume of Raw Sewage?

Filter Volume given Volume of Raw Sewage calculator uses Volumetric Flow Rate = (Total Organic Load*Volume of Raw Sewage)/(Volume of Recirculated Sewage*Organic Loading) to calculate the Volumetric Flow Rate, The Filter Volume given Volume of Raw Sewage formula is defined as the measure of the volume of filter material needed in a treatment system to adequately process a given volume of raw sewage. The filter volume is crucial in various treatment processes, such as sand filters, trickling filters, or other biofilters, where raw sewage is passed through a filtering medium to remove suspended solids and other contaminants. Volumetric Flow Rate is denoted by V symbol.

How to calculate Filter Volume given Volume of Raw Sewage using this online calculator? To use this online calculator for Filter Volume given Volume of Raw Sewage, enter Total Organic Load (Y), Volume of Raw Sewage (I), Volume of Recirculated Sewage (R) & Organic Loading (VL) and hit the calculate button. Here is how the Filter Volume given Volume of Raw Sewage calculation can be explained with given input values -> 5.018569 = (0.000925925925925926*20)/(3*0.00131).

FAQ

What is Filter Volume given Volume of Raw Sewage?
The Filter Volume given Volume of Raw Sewage formula is defined as the measure of the volume of filter material needed in a treatment system to adequately process a given volume of raw sewage. The filter volume is crucial in various treatment processes, such as sand filters, trickling filters, or other biofilters, where raw sewage is passed through a filtering medium to remove suspended solids and other contaminants and is represented as V = (Y*I)/(R*VL) or Volumetric Flow Rate = (Total Organic Load*Volume of Raw Sewage)/(Volume of Recirculated Sewage*Organic Loading). Total organic load is the total amount of organic material present in a water or wastewater sample, Volume of raw sewage means the volume of sewage generated recently, Volume of Recirculated Sewage means the volume of sewage after the recirculation & Organic Loading is defined as the application of soluble and particulate organic matter.
How to calculate Filter Volume given Volume of Raw Sewage?
The Filter Volume given Volume of Raw Sewage formula is defined as the measure of the volume of filter material needed in a treatment system to adequately process a given volume of raw sewage. The filter volume is crucial in various treatment processes, such as sand filters, trickling filters, or other biofilters, where raw sewage is passed through a filtering medium to remove suspended solids and other contaminants is calculated using Volumetric Flow Rate = (Total Organic Load*Volume of Raw Sewage)/(Volume of Recirculated Sewage*Organic Loading). To calculate Filter Volume given Volume of Raw Sewage, you need Total Organic Load (Y), Volume of Raw Sewage (I), Volume of Recirculated Sewage (R) & Organic Loading (VL). With our tool, you need to enter the respective value for Total Organic Load, Volume of Raw Sewage, Volume of Recirculated Sewage & Organic Loading and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!