Filter Length given Organic Loading Solution

STEP 0: Pre-Calculation Summary
Formula Used
Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter)
Lf = BOD5/(OL*A)
This formula uses 4 Variables
Variables Used
Filter Length - (Measured in Meter) - The Filter Length refers to the total length of filter required to effectively do the filtering process.
BOD Loading to Filter - (Measured in Kilogram per Second) - BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume.
Organic Loading - (Measured in Kilogram per Second Square Meter) - Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater.
Area of Filter - (Measured in Square Meter) - The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²).
STEP 1: Convert Input(s) to Base Unit
BOD Loading to Filter: 225 Kilogram per Day --> 0.00260416666666667 Kilogram per Second (Check conversion ​here)
Organic Loading: 30 kilogram per Day Square Meter --> 0.000347222222222222 Kilogram per Second Square Meter (Check conversion ​here)
Area of Filter: 3 Square Meter --> 3 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lf = BOD5/(OL*A) --> 0.00260416666666667/(0.000347222222222222*3)
Evaluating ... ...
Lf = 2.5
STEP 3: Convert Result to Output's Unit
2.5 Meter --> No Conversion Required
FINAL ANSWER
2.5 Meter <-- Filter Length
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Organic Loading Calculators

Organic Loading to Trickling Filter
​ LaTeX ​ Go Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length))
Area of Filter given Organic Loading
​ LaTeX ​ Go Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length)
Filter Length given Organic Loading
​ LaTeX ​ Go Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter)
BOD Load given Organic Loading
​ LaTeX ​ Go BOD Loading to Filter = Organic Loading*Area of Filter*Filter Length

Filter Length given Organic Loading Formula

​LaTeX ​Go
Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter)
Lf = BOD5/(OL*A)

What is Organic Loading Rate ?

Organic Loading Rate is defined as the application of soluble and particulate organic matter. It is typically expressed on an area basis as pounds of BOD5 per unit area per unit time, such as pounds of BOD5 per square foot per day (lb/ft2/day).

How to Calculate Filter Length given Organic Loading?

Filter Length given Organic Loading calculator uses Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter) to calculate the Filter Length, The Filter Length given Organic Loading is defined as the length of a filtration system required to achieve desired treatment goals, calculated based on the organic loading rate and hydraulic residence time. Filter Length is denoted by Lf symbol.

How to calculate Filter Length given Organic Loading using this online calculator? To use this online calculator for Filter Length given Organic Loading, enter BOD Loading to Filter (BOD5), Organic Loading (OL) & Area of Filter (A) and hit the calculate button. Here is how the Filter Length given Organic Loading calculation can be explained with given input values -> 2.5 = 0.00260416666666667/(0.000347222222222222*3).

FAQ

What is Filter Length given Organic Loading?
The Filter Length given Organic Loading is defined as the length of a filtration system required to achieve desired treatment goals, calculated based on the organic loading rate and hydraulic residence time and is represented as Lf = BOD5/(OL*A) or Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter). BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume, Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater & The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²).
How to calculate Filter Length given Organic Loading?
The Filter Length given Organic Loading is defined as the length of a filtration system required to achieve desired treatment goals, calculated based on the organic loading rate and hydraulic residence time is calculated using Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter). To calculate Filter Length given Organic Loading, you need BOD Loading to Filter (BOD5), Organic Loading (OL) & Area of Filter (A). With our tool, you need to enter the respective value for BOD Loading to Filter, Organic Loading & Area of Filter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.