Fault Current using C-Phase Voltage (LLGF) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fault Current = C Phase Voltage/Fault Impedance
If = Vc/Zf
This formula uses 3 Variables
Variables Used
Fault Current - (Measured in Ampere) - The fault current is the electrical current which flows through a circuit during an electrical fault condition.
C Phase Voltage - (Measured in Volt) - C phase Voltage is defined as the voltage of c-phase.
Fault Impedance - (Measured in Ohm) - Fault Impedance is a measure of the resistance and reactance in an electrical circuit that is used to calculate the fault current that flows through the circuit in the event of a fault.
STEP 1: Convert Input(s) to Base Unit
C Phase Voltage: 17.2 Volt --> 17.2 Volt No Conversion Required
Fault Impedance: 1.5 Ohm --> 1.5 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
If = Vc/Zf --> 17.2/1.5
Evaluating ... ...
If = 11.4666666666667
STEP 3: Convert Result to Output's Unit
11.4666666666667 Ampere --> No Conversion Required
FINAL ANSWER
11.4666666666667 11.46667 Ampere <-- Fault Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Current Calculators

Fault Current using B-Phase Voltage (LLGF)
​ LaTeX ​ Go Fault Current = B Phase Voltage/Fault Impedance
B-Phase Current (LLGF)
​ LaTeX ​ Go B Phase Current = Fault Current-C Phase Current
C-Phase Current (LLGF)
​ LaTeX ​ Go C Phase Current = Fault Current-B Phase Current
Fault Current (LLGF)
​ LaTeX ​ Go Fault Current = B Phase Current+C Phase Current

Fault Current using C-Phase Voltage (LLGF) Formula

​LaTeX ​Go
Fault Current = C Phase Voltage/Fault Impedance
If = Vc/Zf

What does three phase voltage mean?

Three-phase power can be defined as the common method of alternating current power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electric grids worldwide to transfer power.

What is fault impedance and current?

Fault Current for the double line to ground fault(LLGF) is defined as the current that flows into the fault Impedance and fault impedance is defined as the impedance which is connected to the earth.

How to Calculate Fault Current using C-Phase Voltage (LLGF)?

Fault Current using C-Phase Voltage (LLGF) calculator uses Fault Current = C Phase Voltage/Fault Impedance to calculate the Fault Current, The Fault current using c-phase Voltage (LLGF) formula is defined as the current that flows into the fault Impedance. Fault Current is denoted by If symbol.

How to calculate Fault Current using C-Phase Voltage (LLGF) using this online calculator? To use this online calculator for Fault Current using C-Phase Voltage (LLGF), enter C Phase Voltage (Vc) & Fault Impedance (Zf) and hit the calculate button. Here is how the Fault Current using C-Phase Voltage (LLGF) calculation can be explained with given input values -> 10.4 = 17.2/1.5.

FAQ

What is Fault Current using C-Phase Voltage (LLGF)?
The Fault current using c-phase Voltage (LLGF) formula is defined as the current that flows into the fault Impedance and is represented as If = Vc/Zf or Fault Current = C Phase Voltage/Fault Impedance. C phase Voltage is defined as the voltage of c-phase & Fault Impedance is a measure of the resistance and reactance in an electrical circuit that is used to calculate the fault current that flows through the circuit in the event of a fault.
How to calculate Fault Current using C-Phase Voltage (LLGF)?
The Fault current using c-phase Voltage (LLGF) formula is defined as the current that flows into the fault Impedance is calculated using Fault Current = C Phase Voltage/Fault Impedance. To calculate Fault Current using C-Phase Voltage (LLGF), you need C Phase Voltage (Vc) & Fault Impedance (Zf). With our tool, you need to enter the respective value for C Phase Voltage & Fault Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Fault Current?
In this formula, Fault Current uses C Phase Voltage & Fault Impedance. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Fault Current = B Phase Current+C Phase Current
  • Fault Current = B Phase Voltage/Fault Impedance