10000, 0.7 < Pr < 160, and tubes where L/d > 60 (the same constraints as the Sieder–Tate correlation).' /> 10000, 0.7 < Pr < 160, and tubes where L/d > 60 (the same constraints as the Sieder–Tate correlation).' />

Fanning Friction Factor given Colburn J-Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fanning Friction Factor = 2*Colburn's j-factor
f = 2*jH
This formula uses 2 Variables
Variables Used
Fanning Friction Factor - The Fanning friction factor is a dimensionless number used in studying fluid friction in pipes. This friction factor is an indication of the resistance to fluid flow at the pipe wall.
Colburn's j-factor - Colburn's j-factor is a non-dimensional parameter that arises in convective heat transfer analysis.
STEP 1: Convert Input(s) to Base Unit
Colburn's j-factor: 0.0046 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = 2*jH --> 2*0.0046
Evaluating ... ...
f = 0.0092
STEP 3: Convert Result to Output's Unit
0.0092 --> No Conversion Required
FINAL ANSWER
0.0092 <-- Fanning Friction Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Basics of Heat Transfer Calculators

Log Mean Temperature Difference for Counter Current Flow
​ LaTeX ​ Go Log Mean Temperature Difference = ((Outlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)-(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))/ln((Outlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
Log Mean Temperature Difference for CoCurrent Flow
​ LaTeX ​ Go Log Mean Temperature Difference = ((Outlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)-(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid))/ln((Outlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid))
Logarithmic Mean Area of Cylinder
​ LaTeX ​ Go Logarithmic Mean Area = (Outer Area of Cylinder-Inner Area of Cylinder)/ln(Outer Area of Cylinder/Inner Area of Cylinder)
Heat Transfer Coefficient based on Temperature Difference
​ LaTeX ​ Go Heat Transfer Coefficient = Heat Transfer/Overall Temperature Difference

Fanning Friction Factor given Colburn J-Factor Formula

​LaTeX ​Go
Fanning Friction Factor = 2*Colburn's j-factor
f = 2*jH

What is Heat Transfer?

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes.

Define Thermal Conductivity & Factors affecting it?

Thermal conductivity is defined as the ability of a substance to conduct heat. Factors Affecting The Thermal Conductivity are: Moisture, Density of material, Pressure, Temperature & Structure of material.

How to Calculate Fanning Friction Factor given Colburn J-Factor?

Fanning Friction Factor given Colburn J-Factor calculator uses Fanning Friction Factor = 2*Colburn's j-factor to calculate the Fanning Friction Factor, The Fanning Friction Factor given Colburn J-Factor formula is defined as the product of 2 and Colburn J-Factor. Chilton–Colburn J-factor analogy (also known as the modified Reynolds analogy) is a successful and widely used analogy between heat, momentum, and mass transfer. The above equation permits the prediction of an unknown transfer coefficient when one of the other coefficients is known. The analogy is valid for fully developed turbulent flow in conduits with Re > 10000, 0.7 < Pr < 160, and tubes where L/d > 60 (the same constraints as the Sieder–Tate correlation). Fanning Friction Factor is denoted by f symbol.

How to calculate Fanning Friction Factor given Colburn J-Factor using this online calculator? To use this online calculator for Fanning Friction Factor given Colburn J-Factor, enter Colburn's j-factor (jH) and hit the calculate button. Here is how the Fanning Friction Factor given Colburn J-Factor calculation can be explained with given input values -> 0.0092 = 2*0.0046.

FAQ

What is Fanning Friction Factor given Colburn J-Factor?
The Fanning Friction Factor given Colburn J-Factor formula is defined as the product of 2 and Colburn J-Factor. Chilton–Colburn J-factor analogy (also known as the modified Reynolds analogy) is a successful and widely used analogy between heat, momentum, and mass transfer. The above equation permits the prediction of an unknown transfer coefficient when one of the other coefficients is known. The analogy is valid for fully developed turbulent flow in conduits with Re > 10000, 0.7 < Pr < 160, and tubes where L/d > 60 (the same constraints as the Sieder–Tate correlation) and is represented as f = 2*jH or Fanning Friction Factor = 2*Colburn's j-factor. Colburn's j-factor is a non-dimensional parameter that arises in convective heat transfer analysis.
How to calculate Fanning Friction Factor given Colburn J-Factor?
The Fanning Friction Factor given Colburn J-Factor formula is defined as the product of 2 and Colburn J-Factor. Chilton–Colburn J-factor analogy (also known as the modified Reynolds analogy) is a successful and widely used analogy between heat, momentum, and mass transfer. The above equation permits the prediction of an unknown transfer coefficient when one of the other coefficients is known. The analogy is valid for fully developed turbulent flow in conduits with Re > 10000, 0.7 < Pr < 160, and tubes where L/d > 60 (the same constraints as the Sieder–Tate correlation) is calculated using Fanning Friction Factor = 2*Colburn's j-factor. To calculate Fanning Friction Factor given Colburn J-Factor, you need Colburn's j-factor (jH). With our tool, you need to enter the respective value for Colburn's j-factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!