Excess Carrier Concentration Solution

STEP 0: Pre-Calculation Summary
Formula Used
Excess Carrier Concentration = Optical Generation Rate*Recombination Lifetime
δn = gop*τn
This formula uses 3 Variables
Variables Used
Excess Carrier Concentration - (Measured in 1 per Cubic Meter) - Excess Carrier Concentration is extra of electron present in the carrier concentration.
Optical Generation Rate - Optical Generation Rate the number of electrons generated at each point in the device due to the absorption of photons.
Recombination Lifetime - (Measured in Second) - Recombination Lifetime the average time it takes an excess minority carrier to recombine.
STEP 1: Convert Input(s) to Base Unit
Optical Generation Rate: 2.9E+19 --> No Conversion Required
Recombination Lifetime: 3.62E-06 Second --> 3.62E-06 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
δn = gopn --> 2.9E+19*3.62E-06
Evaluating ... ...
δn = 104980000000000
STEP 3: Convert Result to Output's Unit
104980000000000 1 per Cubic Meter --> No Conversion Required
FINAL ANSWER
104980000000000 1E+14 1 per Cubic Meter <-- Excess Carrier Concentration
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Energy Band and Charge Carrier Calculators

Energy of Electron given Coulomb's Constant
​ LaTeX ​ Go Energy of Electron = (Quantum Number^2*pi^2*[hP]^2)/(2*[Mass-e]*Potential Well Length^2)
Steady State Electron Concentration
​ LaTeX ​ Go Steady State Carrier Concentration = Electron Concentration in Conduction Band+Excess Carrier Concentration
Valence Band Energy
​ LaTeX ​ Go Valence Band Energy = Conduction Band Energy-Energy Gap
Energy Gap
​ LaTeX ​ Go Energy Gap = Conduction Band Energy-Valence Band Energy

Semiconductor Carriers Calculators

Fermi Function
​ LaTeX ​ Go Fermi Function = Electron Concentration in Conduction Band/Effective Density of State in Conduction Band
Distribution Coefficient
​ LaTeX ​ Go Distribution Coefficient = Impurity Concentration in Solid/Impurity Concentration in Liquid
Photoelectron Energy
​ LaTeX ​ Go Photoelectron Energy = [hP]*Frequency of Incident Light
Conduction Band Energy
​ LaTeX ​ Go Conduction Band Energy = Energy Gap+Valence Band Energy

Excess Carrier Concentration Formula

​LaTeX ​Go
Excess Carrier Concentration = Optical Generation Rate*Recombination Lifetime
δn = gop*τn

How do you increase carrier concentration?

The lowering the temperature causes a decrease in the intrinsic carrier concentration, while raising the temperature causes an increase in intrinsic carrier concentration

How to Calculate Excess Carrier Concentration?

Excess Carrier Concentration calculator uses Excess Carrier Concentration = Optical Generation Rate*Recombination Lifetime to calculate the Excess Carrier Concentration, The Excess Carrier Concentration formula is defined as The number of majority carriers per unit volume, expressed in dimensionless units such as percentage, parts per million, or parts per billion. Excess Carrier Concentration is denoted by δn symbol.

How to calculate Excess Carrier Concentration using this online calculator? To use this online calculator for Excess Carrier Concentration, enter Optical Generation Rate (gop) & Recombination Lifetime n) and hit the calculate button. Here is how the Excess Carrier Concentration calculation can be explained with given input values -> 1E+14 = 2.9E+19*3.62E-06.

FAQ

What is Excess Carrier Concentration?
The Excess Carrier Concentration formula is defined as The number of majority carriers per unit volume, expressed in dimensionless units such as percentage, parts per million, or parts per billion and is represented as δn = gopn or Excess Carrier Concentration = Optical Generation Rate*Recombination Lifetime. Optical Generation Rate the number of electrons generated at each point in the device due to the absorption of photons & Recombination Lifetime the average time it takes an excess minority carrier to recombine.
How to calculate Excess Carrier Concentration?
The Excess Carrier Concentration formula is defined as The number of majority carriers per unit volume, expressed in dimensionless units such as percentage, parts per million, or parts per billion is calculated using Excess Carrier Concentration = Optical Generation Rate*Recombination Lifetime. To calculate Excess Carrier Concentration, you need Optical Generation Rate (gop) & Recombination Lifetime n). With our tool, you need to enter the respective value for Optical Generation Rate & Recombination Lifetime and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!