Equivalent Impedance of Transformer from Secondary Side Solution

STEP 0: Pre-Calculation Summary
Formula Used
Equivalent Impedance from Secondary = sqrt(Equivalent Resistance from Secondary^2+Equivalent Reactance from Secondary^2)
Z02 = sqrt(R02^2+X02^2)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Equivalent Impedance from Secondary - (Measured in Ohm) - The Equivalent Impedance from Secondary side is the total Impedance of the secondary side.
Equivalent Resistance from Secondary - (Measured in Ohm) - Equivalent resistance from Secondary side is the total secondary side resistance.
Equivalent Reactance from Secondary - (Measured in Ohm) - The Equivalent Reactance from Secondary side is the total Reactance of the Secondary side.
STEP 1: Convert Input(s) to Base Unit
Equivalent Resistance from Secondary: 51.79 Ohm --> 51.79 Ohm No Conversion Required
Equivalent Reactance from Secondary: 2.23 Ohm --> 2.23 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z02 = sqrt(R02^2+X02^2) --> sqrt(51.79^2+2.23^2)
Evaluating ... ...
Z02 = 51.8379880010789
STEP 3: Convert Result to Output's Unit
51.8379880010789 Ohm --> No Conversion Required
FINAL ANSWER
51.8379880010789 51.83799 Ohm <-- Equivalent Impedance from Secondary
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Impedance Calculators

Impedance of Secondary Winding given Secondary Parameters
​ LaTeX ​ Go Impedance of Secondary = (EMF Induced in Secondary-Secondary Voltage)/Secondary Current
Impedance of Secondary Winding
​ LaTeX ​ Go Impedance of Secondary = sqrt(Resistance of Secondary^2+Secondary Leakage Reactance^2)
Impedance of Primary Winding
​ LaTeX ​ Go Impedance of Primary = sqrt(Resistance of Primary^2+Primary Leakage Reactance^2)
Impedance of Primary Winding given Primary Parameters
​ LaTeX ​ Go Impedance of Primary = (Primary Voltage-EMF Induced in Primary)/Primary Current

Transformer Circuit Calculators

Equivalent Reactance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary
Equivalent Reactance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Reactance from Primary = Primary Leakage Reactance+Reactance of Secondary in Primary
Primary Leakage Reactance
​ LaTeX ​ Go Primary Leakage Reactance = Reactance of Primary in Secondary/(Transformation Ratio^2)
Reactance of Primary Winding in Secondary
​ LaTeX ​ Go Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2

Equivalent Impedance of Transformer from Secondary Side Formula

​LaTeX ​Go
Equivalent Impedance from Secondary = sqrt(Equivalent Resistance from Secondary^2+Equivalent Reactance from Secondary^2)
Z02 = sqrt(R02^2+X02^2)

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Equivalent Impedance of Transformer from Secondary Side?

Equivalent Impedance of Transformer from Secondary Side calculator uses Equivalent Impedance from Secondary = sqrt(Equivalent Resistance from Secondary^2+Equivalent Reactance from Secondary^2) to calculate the Equivalent Impedance from Secondary, The Equivalent Impedance of Transformer from Secondary Side formula is defined as the sqrt of the sum of the Equivalent resistance Of Transformer From Secondary Side and Equivalent reactance Of Transformer From Secondary Side. Equivalent Impedance from Secondary is denoted by Z02 symbol.

How to calculate Equivalent Impedance of Transformer from Secondary Side using this online calculator? To use this online calculator for Equivalent Impedance of Transformer from Secondary Side, enter Equivalent Resistance from Secondary (R02) & Equivalent Reactance from Secondary (X02) and hit the calculate button. Here is how the Equivalent Impedance of Transformer from Secondary Side calculation can be explained with given input values -> 51.83799 = sqrt(51.79^2+2.23^2).

FAQ

What is Equivalent Impedance of Transformer from Secondary Side?
The Equivalent Impedance of Transformer from Secondary Side formula is defined as the sqrt of the sum of the Equivalent resistance Of Transformer From Secondary Side and Equivalent reactance Of Transformer From Secondary Side and is represented as Z02 = sqrt(R02^2+X02^2) or Equivalent Impedance from Secondary = sqrt(Equivalent Resistance from Secondary^2+Equivalent Reactance from Secondary^2). Equivalent resistance from Secondary side is the total secondary side resistance & The Equivalent Reactance from Secondary side is the total Reactance of the Secondary side.
How to calculate Equivalent Impedance of Transformer from Secondary Side?
The Equivalent Impedance of Transformer from Secondary Side formula is defined as the sqrt of the sum of the Equivalent resistance Of Transformer From Secondary Side and Equivalent reactance Of Transformer From Secondary Side is calculated using Equivalent Impedance from Secondary = sqrt(Equivalent Resistance from Secondary^2+Equivalent Reactance from Secondary^2). To calculate Equivalent Impedance of Transformer from Secondary Side, you need Equivalent Resistance from Secondary (R02) & Equivalent Reactance from Secondary (X02). With our tool, you need to enter the respective value for Equivalent Resistance from Secondary & Equivalent Reactance from Secondary and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!