Enthalpy of Moist Air Solution

STEP 0: Pre-Calculation Summary
Formula Used
Enthalpy of Moist Air = 1.005*Dry Bulb Temperature in °C+Specific Humidity*(2500+1.9*Dry Bulb Temperature in °C)
h = 1.005*tdb+ω*(2500+1.9*tdb)
This formula uses 3 Variables
Variables Used
Enthalpy of Moist Air - (Measured in Kilojoule per Kilogram) - The Enthalpy of Moist Air is the sum of the enthalpy of the dry air and the enthalpy of the water vapour.
Dry Bulb Temperature in °C - Dry Bulb Temperature in °C is the temperature of air measured by a thermometer freely exposed to the air but shielded from radiation and moisture.
Specific Humidity - Specific Humidity is the ratio of the mass of water vapor to the total mass of the air parcel.
STEP 1: Convert Input(s) to Base Unit
Dry Bulb Temperature in °C: 110 --> No Conversion Required
Specific Humidity: 0.25 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h = 1.005*tdb+ω*(2500+1.9*tdb) --> 1.005*110+0.25*(2500+1.9*110)
Evaluating ... ...
h = 787.8
STEP 3: Convert Result to Output's Unit
787800 Joule per Kilogram -->787.8 Kilojoule per Kilogram (Check conversion ​here)
FINAL ANSWER
787.8 Kilojoule per Kilogram <-- Enthalpy of Moist Air
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ravi Khiyani
Shri Govindram Seksaria Institute of Technology and Science (SGSITS), Indore
Ravi Khiyani has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Enthalpy of Air Calculators

Coefficient of Performance given enthalpy of liquid refrigerant leaving condenser (hf3)
​ LaTeX ​ Go Theoretical Coefficient of Performance = (Enthalpy of The Vapour Refrigerant at T1-Sensible Heat at Temperature T3)/(Enthalpy of The Vapour Refrigerant at T2-Enthalpy of The Vapour Refrigerant at T1)
Refrigerating Effect(for given h1 and h4)
​ LaTeX ​ Go Refrigerating Effect = Enthalpy of The Vapour Refrigerant at T1-Enthalpy of The Vapour Refrigerant at T4
Refrigerating Effect given Enthalpy at Inlet of Compressor and Exit of Condenser
​ LaTeX ​ Go Refrigerating Effect = Enthalpy of The Vapour Refrigerant at T1-Sensible Heat at Temperature T3
Work done during isentropic compression(per Kg of refrigerant)
​ LaTeX ​ Go Work Done = Enthalpy of The Vapour Refrigerant at T2-Enthalpy of The Vapour Refrigerant at T1

Enthalpy of Moist Air Formula

​LaTeX ​Go
Enthalpy of Moist Air = 1.005*Dry Bulb Temperature in °C+Specific Humidity*(2500+1.9*Dry Bulb Temperature in °C)
h = 1.005*tdb+ω*(2500+1.9*tdb)

What is dry-bulb temperature?

The Dry Bulb Temperature refers basically to the ambient air temperature. It is called "Dry Bulb" because the air temperature is indicated by a thermometer not affected by the moisture of the air. When people refer to the temperature of the air they are normally referring to the dry bulb temperature.

How to Calculate Enthalpy of Moist Air?

Enthalpy of Moist Air calculator uses Enthalpy of Moist Air = 1.005*Dry Bulb Temperature in °C+Specific Humidity*(2500+1.9*Dry Bulb Temperature in °C) to calculate the Enthalpy of Moist Air, Enthalpy of Moist Air formula is defined as the total heat content of moist air per unit mass, which is a measure of the total energy of the air, including the energy associated with the temperature and humidity of the air. Enthalpy of Moist Air is denoted by h symbol.

How to calculate Enthalpy of Moist Air using this online calculator? To use this online calculator for Enthalpy of Moist Air, enter Dry Bulb Temperature in °C (tdb) & Specific Humidity (ω) and hit the calculate button. Here is how the Enthalpy of Moist Air calculation can be explained with given input values -> 0.7878 = 1.005*110+0.25*(2500+1.9*110).

FAQ

What is Enthalpy of Moist Air?
Enthalpy of Moist Air formula is defined as the total heat content of moist air per unit mass, which is a measure of the total energy of the air, including the energy associated with the temperature and humidity of the air and is represented as h = 1.005*tdb+ω*(2500+1.9*tdb) or Enthalpy of Moist Air = 1.005*Dry Bulb Temperature in °C+Specific Humidity*(2500+1.9*Dry Bulb Temperature in °C). Dry Bulb Temperature in °C is the temperature of air measured by a thermometer freely exposed to the air but shielded from radiation and moisture & Specific Humidity is the ratio of the mass of water vapor to the total mass of the air parcel.
How to calculate Enthalpy of Moist Air?
Enthalpy of Moist Air formula is defined as the total heat content of moist air per unit mass, which is a measure of the total energy of the air, including the energy associated with the temperature and humidity of the air is calculated using Enthalpy of Moist Air = 1.005*Dry Bulb Temperature in °C+Specific Humidity*(2500+1.9*Dry Bulb Temperature in °C). To calculate Enthalpy of Moist Air, you need Dry Bulb Temperature in °C (tdb) & Specific Humidity (ω). With our tool, you need to enter the respective value for Dry Bulb Temperature in °C & Specific Humidity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.