Enthalpy at Point 4 given Liquid Enthalpy at Point 4 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion)
h4 = hf4+(x4*hfg)
This formula uses 4 Variables
Variables Used
Enthalpy of The Vapour Refrigerant at T4 - (Measured in Joule per Kilogram) - Enthalpy of the Vapour Refrigerant at T4 is the total heat content of the refrigerant vapour at the fourth point in the vapour compression refrigeration cycle.
Liquid Enthalpy at Point 4 - (Measured in Joule per Kilogram) - Liquid Enthalpy at Point 4 is the total heat content of the refrigerant at the fourth point in a vapour compression refrigeration cycle.
Dryness Fraction at Point 4 - Dryness Fraction at Point 4 is the measure of the amount of dry air in the refrigerant at the fourth point of the vapour compression refrigeration cycle.
Latent Heat of Fusion - (Measured in Joule per Kilogram) - Latent Heat of Fusion is the energy required to change the state of a substance from solid to liquid during the vapour compression refrigeration cycle.
STEP 1: Convert Input(s) to Base Unit
Liquid Enthalpy at Point 4: 80 Kilojoule per Kilogram --> 80000 Joule per Kilogram (Check conversion ​here)
Dryness Fraction at Point 4: 0.01 --> No Conversion Required
Latent Heat of Fusion: 1000 Kilojoule per Kilogram --> 1000000 Joule per Kilogram (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h4 = hf4+(x4*hfg) --> 80000+(0.01*1000000)
Evaluating ... ...
h4 = 90000
STEP 3: Convert Result to Output's Unit
90000 Joule per Kilogram -->90 Kilojoule per Kilogram (Check conversion ​here)
FINAL ANSWER
90 Kilojoule per Kilogram <-- Enthalpy of The Vapour Refrigerant at T4
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rushi Shah
K J Somaiya College of Engineering (K J Somaiya), Mumbai
Rushi Shah has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has verified this Calculator and 50+ more calculators!

Enthalpy of Vapour Compression Refrigeration Cycle Calculators

Entropy at point 1
​ LaTeX ​ Go Entropy at Point 1 = Liquid Entropy at Point 1+((Dryness Fraction at Point 1*Latent Heat of Fusion)/Temperature at The Suction of Compressor)
Enthalpy at Point 4 given Liquid Enthalpy at Point 4
​ LaTeX ​ Go Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion)
Enthalpy at point 2
​ LaTeX ​ Go Enthalpy of The Vapour Refrigerant at T2 = Liquid Enthalpy at Point 2+(Dryness Fraction at Point 2*Latent Heat of Fusion)
Enthalpy at point 1 given Liquid enthalpy at point 1
​ LaTeX ​ Go Enthalpy of The Vapour Refrigerant at T1 = Liquid Enthalpy at Point 1+Dryness Fraction at Point 1*Latent Heat of Fusion

Enthalpy of Air Calculators

Coefficient of Performance given enthalpy of liquid refrigerant leaving condenser (hf3)
​ LaTeX ​ Go Theoretical Coefficient of Performance = (Enthalpy of The Vapour Refrigerant at T1-Sensible Heat at Temperature T3)/(Enthalpy of The Vapour Refrigerant at T2-Enthalpy of The Vapour Refrigerant at T1)
Refrigerating Effect(for given h1 and h4)
​ LaTeX ​ Go Refrigerating Effect = Enthalpy of The Vapour Refrigerant at T1-Enthalpy of The Vapour Refrigerant at T4
Refrigerating Effect given Enthalpy at Inlet of Compressor and Exit of Condenser
​ LaTeX ​ Go Refrigerating Effect = Enthalpy of The Vapour Refrigerant at T1-Sensible Heat at Temperature T3
Work done during isentropic compression(per Kg of refrigerant)
​ LaTeX ​ Go Work Done = Enthalpy of The Vapour Refrigerant at T2-Enthalpy of The Vapour Refrigerant at T1

Enthalpy at Point 4 given Liquid Enthalpy at Point 4 Formula

​LaTeX ​Go
Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion)
h4 = hf4+(x4*hfg)

What is Enthalpy?

Heat content is also known as enthalpy. It is a measure of how much heat a gas or liquid can hold and how much heat is needed to change the temperature.

How to Calculate Enthalpy at Point 4 given Liquid Enthalpy at Point 4?

Enthalpy at Point 4 given Liquid Enthalpy at Point 4 calculator uses Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion) to calculate the Enthalpy of The Vapour Refrigerant at T4, Enthalpy at Point 4 given Liquid Enthalpy at Point 4 formula is defined as the total heat content of a system at point 4, which is the sum of the liquid enthalpy at point 4 and the product of the quality of the mixture at point 4 and the latent heat of vaporization. Enthalpy of The Vapour Refrigerant at T4 is denoted by h4 symbol.

How to calculate Enthalpy at Point 4 given Liquid Enthalpy at Point 4 using this online calculator? To use this online calculator for Enthalpy at Point 4 given Liquid Enthalpy at Point 4, enter Liquid Enthalpy at Point 4 (hf4), Dryness Fraction at Point 4 (x4) & Latent Heat of Fusion (hfg) and hit the calculate button. Here is how the Enthalpy at Point 4 given Liquid Enthalpy at Point 4 calculation can be explained with given input values -> 0.09 = 80000+(0.01*1000000).

FAQ

What is Enthalpy at Point 4 given Liquid Enthalpy at Point 4?
Enthalpy at Point 4 given Liquid Enthalpy at Point 4 formula is defined as the total heat content of a system at point 4, which is the sum of the liquid enthalpy at point 4 and the product of the quality of the mixture at point 4 and the latent heat of vaporization and is represented as h4 = hf4+(x4*hfg) or Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion). Liquid Enthalpy at Point 4 is the total heat content of the refrigerant at the fourth point in a vapour compression refrigeration cycle, Dryness Fraction at Point 4 is the measure of the amount of dry air in the refrigerant at the fourth point of the vapour compression refrigeration cycle & Latent Heat of Fusion is the energy required to change the state of a substance from solid to liquid during the vapour compression refrigeration cycle.
How to calculate Enthalpy at Point 4 given Liquid Enthalpy at Point 4?
Enthalpy at Point 4 given Liquid Enthalpy at Point 4 formula is defined as the total heat content of a system at point 4, which is the sum of the liquid enthalpy at point 4 and the product of the quality of the mixture at point 4 and the latent heat of vaporization is calculated using Enthalpy of The Vapour Refrigerant at T4 = Liquid Enthalpy at Point 4+(Dryness Fraction at Point 4*Latent Heat of Fusion). To calculate Enthalpy at Point 4 given Liquid Enthalpy at Point 4, you need Liquid Enthalpy at Point 4 (hf4), Dryness Fraction at Point 4 (x4) & Latent Heat of Fusion (hfg). With our tool, you need to enter the respective value for Liquid Enthalpy at Point 4, Dryness Fraction at Point 4 & Latent Heat of Fusion and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.