Runoff Quantity with Full Gutter Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)
Qro = 0.7*Lo*(a+y)^(3/2)
This formula uses 4 Variables
Variables Used
Runoff Quantity - (Measured in Cubic Meter per Second) - Runoff Quantity is the amount of water that storms bring to the earth.
Length of Opening - (Measured in Meter) - Length of Opening refers to the dimension of the structure that allows water to pass through.
Depression in Curb Inlet - (Measured in Meter) - Depression in Curb Inlet is the height of depression at the curb achieved from the steeper grade of the gutter cross slope relative to the roadway cross-slope.
Depth of Flow at Inlet - (Measured in Meter) - Depth of Flow at Inlet refers to the depth of water in a channel or conduit at the point where water enters a structure, such as a culvert, intake structure, or storm water inlet.
STEP 1: Convert Input(s) to Base Unit
Length of Opening: 7 Foot --> 2.13360000000853 Meter (Check conversion ​here)
Depression in Curb Inlet: 4 Foot --> 1.21920000000488 Meter (Check conversion ​here)
Depth of Flow at Inlet: 7.117 Foot --> 2.16926160000868 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qro = 0.7*Lo*(a+y)^(3/2) --> 0.7*2.13360000000853*(1.21920000000488+2.16926160000868)^(3/2)
Evaluating ... ...
Qro = 9.31568715121965
STEP 3: Convert Result to Output's Unit
9.31568715121965 Cubic Meter per Second -->328.980387023027 Cubic Foot per Second (Check conversion ​here)
FINAL ANSWER
328.980387023027 328.9804 Cubic Foot per Second <-- Runoff Quantity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 200+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

10+ Disposing of Storm Water Calculators

Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Depth = ((Inlet Capacity/(0.6*Area of Opening))^2)*(1/(2*Acceleration due to Gravity in Environment))
Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
​ Go Depression in Curb Inlet = ((Runoff Quantity/(0.7*Length of Opening))^(2/3))-Depth of Flow at Inlet
Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
​ Go Depth of Flow at Inlet = ((Runoff Quantity/(0.7*Length of Opening))^(2/3))-Depression in Curb Inlet
Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity in Environment*Depth)^(1/2))
Length of Opening given Runoff Quantity with Full Gutter Flow
​ Go Length of Opening = Runoff Quantity/(0.7*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2))
Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Inlet Capacity = 0.6*Area of Opening*((2*Acceleration due to Gravity in Environment*Depth)^(1/2))
Runoff Quantity with Full Gutter Flow
​ Go Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)
Depth of Flow at Inlet given Inlet Capacity for Flow Depth up to 4.8in
​ Go Depth of Flow at Inlet = (Water Flow/(3*Perimeter of Grate Opening))^(2/3)
Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches
​ Go Perimeter of Grate Opening = Water Flow/(3*Depth of Flow at Inlet^(3/2))
Inlet Capacity for Flow Depth
​ Go Water Flow = 3*Perimeter of Grate Opening*Depth of Flow at Inlet^(3/2)

Runoff Quantity with Full Gutter Flow Formula

Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)
Qro = 0.7*Lo*(a+y)^(3/2)

What is a Curb Inlet?

Curb Inlets are used to assist in storm water drainage of the street surface area. The Curb Inlet is usually a below ground box structure with a vertical opening at the street level.

How to Calculate Runoff Quantity with Full Gutter Flow?

Runoff Quantity with Full Gutter Flow calculator uses Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2) to calculate the Runoff Quantity, The Runoff quantity with full gutter flow is defined as the amount of the water flow per second when we have a prior info of opening length, depression in curb and depth of flow at the inlet. Runoff Quantity is denoted by Qro symbol.

How to calculate Runoff Quantity with Full Gutter Flow using this online calculator? To use this online calculator for Runoff Quantity with Full Gutter Flow, enter Length of Opening (Lo), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y) and hit the calculate button. Here is how the Runoff Quantity with Full Gutter Flow calculation can be explained with given input values -> 11617.83 = 0.7*2.13360000000853*(1.21920000000488+2.16926160000868)^(3/2).

FAQ

What is Runoff Quantity with Full Gutter Flow?
The Runoff quantity with full gutter flow is defined as the amount of the water flow per second when we have a prior info of opening length, depression in curb and depth of flow at the inlet and is represented as Qro = 0.7*Lo*(a+y)^(3/2) or Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2). Length of Opening refers to the dimension of the structure that allows water to pass through, Depression in Curb Inlet is the height of depression at the curb achieved from the steeper grade of the gutter cross slope relative to the roadway cross-slope & Depth of Flow at Inlet refers to the depth of water in a channel or conduit at the point where water enters a structure, such as a culvert, intake structure, or storm water inlet.
How to calculate Runoff Quantity with Full Gutter Flow?
The Runoff quantity with full gutter flow is defined as the amount of the water flow per second when we have a prior info of opening length, depression in curb and depth of flow at the inlet is calculated using Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2). To calculate Runoff Quantity with Full Gutter Flow, you need Length of Opening (Lo), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y). With our tool, you need to enter the respective value for Length of Opening, Depression in Curb Inlet & Depth of Flow at Inlet and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!