Deflecting torque of PMMC instrument Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC
T = N*B*l*d*i
This formula uses 6 Variables
Variables Used
Deflecting Torque in PMMC - (Measured in Newton Meter) - Deflecting Torque in PMMC is the force applied to a measuring instrument, such as a meter or galvanometer, causing it to rotate. It's proportional to the current passing through the device's coil.
Number of Magnetic Coil Turns - Number of Magnetic Coil Turns specifies the number of turns of the coil of magnetic coil under testing.
Flux Density in PMMC - (Measured in Tesla) - Flux Density in PMMC refers to the concentration of magnetic field lines within the coil's core, crucial for generating the deflecting torque that moves the coil in response to current.
Coil Length - (Measured in Meter) - Coil Length determines the number of turns and the effective area within the magnetic field, crucial for generating a proportional deflection in response to current.
Coil Width - (Measured in Meter) - Coil Width affects the coil's mechanical stability and sensitivity to external influences, such as magnetic fields, ensuring accurate measurement of current by minimizing disturbances.
Total Current in PMMC - (Measured in Ampere) - Total Current in PMMC causes the coil to rotate due to the interaction between the magnetic field of the permanent magnet and the current, indicating the magnitude of the current being measured.
STEP 1: Convert Input(s) to Base Unit
Number of Magnetic Coil Turns: 2 --> No Conversion Required
Flux Density in PMMC: 5.58 Weber per Square Meter --> 5.58 Tesla (Check conversion ​here)
Coil Length: 7 Meter --> 7 Meter No Conversion Required
Coil Width: 2.1 Meter --> 2.1 Meter No Conversion Required
Total Current in PMMC: 0.02 Ampere --> 0.02 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = N*B*l*d*i --> 2*5.58*7*2.1*0.02
Evaluating ... ...
T = 3.28104
STEP 3: Convert Result to Output's Unit
3.28104 Newton Meter --> No Conversion Required
FINAL ANSWER
3.28104 Newton Meter <-- Deflecting Torque in PMMC
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

2 Permanent Magnet Moving Coil (PMMC) Calculators

Angle of deflection of PMMC
​ Go Deflection Angle in PMMC = (Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC)/Spring Constant in PMMC
Deflecting torque of PMMC instrument
​ Go Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC

Deflecting torque of PMMC instrument Formula

Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC
T = N*B*l*d*i

What is PMMC?

PMMC stands for Permanent Magnet Moving Coil. The instruments which use the permanent magnet for creating the stationary magnetic field between which the coil moves are known as a permanent magnet moving coil or PMMC instruments.

How does torque in PMMC work?

When a current flows through the coil, it generates a magnetic field that is proportional to the current in the case of an ammeter. The deflecting torque is produced by the electromagnetic action of the current in the coil and the magnetic field. When the torques are balanced, the moving coil will stop and its angular deflection represents the amount of electrical current to be measured against a fixed reference, called a scale.

How to Calculate Deflecting torque of PMMC instrument?

Deflecting torque of PMMC instrument calculator uses Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC to calculate the Deflecting Torque in PMMC, The Deflecting torque of PMMC instrument is produced by the electromagnetic action of the current in the coil and the magnetic field. Deflecting Torque in PMMC is denoted by T symbol.

How to calculate Deflecting torque of PMMC instrument using this online calculator? To use this online calculator for Deflecting torque of PMMC instrument, enter Number of Magnetic Coil Turns (N), Flux Density in PMMC (B), Coil Length (l), Coil Width (d) & Total Current in PMMC (i) and hit the calculate button. Here is how the Deflecting torque of PMMC instrument calculation can be explained with given input values -> 3.28104 = 2*5.58*7*2.1*0.02.

FAQ

What is Deflecting torque of PMMC instrument?
The Deflecting torque of PMMC instrument is produced by the electromagnetic action of the current in the coil and the magnetic field and is represented as T = N*B*l*d*i or Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC. Number of Magnetic Coil Turns specifies the number of turns of the coil of magnetic coil under testing, Flux Density in PMMC refers to the concentration of magnetic field lines within the coil's core, crucial for generating the deflecting torque that moves the coil in response to current, Coil Length determines the number of turns and the effective area within the magnetic field, crucial for generating a proportional deflection in response to current, Coil Width affects the coil's mechanical stability and sensitivity to external influences, such as magnetic fields, ensuring accurate measurement of current by minimizing disturbances & Total Current in PMMC causes the coil to rotate due to the interaction between the magnetic field of the permanent magnet and the current, indicating the magnitude of the current being measured.
How to calculate Deflecting torque of PMMC instrument?
The Deflecting torque of PMMC instrument is produced by the electromagnetic action of the current in the coil and the magnetic field is calculated using Deflecting Torque in PMMC = Number of Magnetic Coil Turns*Flux Density in PMMC*Coil Length*Coil Width*Total Current in PMMC. To calculate Deflecting torque of PMMC instrument, you need Number of Magnetic Coil Turns (N), Flux Density in PMMC (B), Coil Length (l), Coil Width (d) & Total Current in PMMC (i). With our tool, you need to enter the respective value for Number of Magnetic Coil Turns, Flux Density in PMMC, Coil Length, Coil Width & Total Current in PMMC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!