Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density)
f = E2/(4.44*N2*Acore*Bmax)
This formula uses 5 Variables
Variables Used
Supply Frequency - (Measured in Hertz) - Supply Frequency means Induction motors are designed for a specific voltage per frequency ratio (V/Hz). The voltage is called the supply voltage and the frequency is called the 'Supply Frequency'.
EMF Induced in Secondary - (Measured in Volt) - EMF Induced in Secondary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil.
Number of Turns in Secondary - The Number of Turns in Secondary Winding is the number of turns secondary winding is the winding of a transformer.
Area of Core - (Measured in Square Meter) - Area of Core is defined as the space occupied by the core of a transformer in 2 dimensional space.
Maximum Flux Density - (Measured in Tesla) - Maximum Flux Density is defined as the number of lines of force passing through a unit area of material.
STEP 1: Convert Input(s) to Base Unit
EMF Induced in Secondary: 15.84 Volt --> 15.84 Volt No Conversion Required
Number of Turns in Secondary: 24 --> No Conversion Required
Area of Core: 2500 Square Centimeter --> 0.25 Square Meter (Check conversion ​here)
Maximum Flux Density: 0.0012 Tesla --> 0.0012 Tesla No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = E2/(4.44*N2*Acore*Bmax) --> 15.84/(4.44*24*0.25*0.0012)
Evaluating ... ...
f = 495.495495495496
STEP 3: Convert Result to Output's Unit
495.495495495496 Hertz --> No Conversion Required
FINAL ANSWER
495.495495495496 495.4955 Hertz <-- Supply Frequency
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Frequency Calculators

Frequency given EMF Induced in Secondary Winding
​ LaTeX ​ Go Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density)
Frequency given EMF Induced in Primary Winding
​ LaTeX ​ Go Supply Frequency = EMF Induced in Primary/(4.44*Number of Turns in Primary*Area of Core*Maximum Flux Density)

Transformer Circuit Calculators

Equivalent Reactance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary
Equivalent Reactance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Reactance from Primary = Primary Leakage Reactance+Reactance of Secondary in Primary
Primary Leakage Reactance
​ LaTeX ​ Go Primary Leakage Reactance = Reactance of Primary in Secondary/(Transformation Ratio^2)
Reactance of Primary Winding in Secondary
​ LaTeX ​ Go Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2

Frequency given EMF Induced in Secondary Winding Formula

​LaTeX ​Go
Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density)
f = E2/(4.44*N2*Acore*Bmax)

What is induced EMF?

Alternating flux gets linked with the secondary winding, and because of the phenomenon of mutual induction, an emf gets induced in the secondary winding. The magnitude of this induced emf can be found by using the following EMF equation of the transformer.

How to Calculate Frequency given EMF Induced in Secondary Winding?

Frequency given EMF Induced in Secondary Winding calculator uses Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density) to calculate the Supply Frequency, Frequency given EMF Induced in Secondary Winding formula is defined as the number of occurrences of a periodic event per time and is measured in cycles/second. The magnitude of this induced emf can be found by using the following EMF equation of the transformer. Supply Frequency is denoted by f symbol.

How to calculate Frequency given EMF Induced in Secondary Winding using this online calculator? To use this online calculator for Frequency given EMF Induced in Secondary Winding, enter EMF Induced in Secondary (E2), Number of Turns in Secondary (N2), Area of Core (Acore) & Maximum Flux Density (Bmax) and hit the calculate button. Here is how the Frequency given EMF Induced in Secondary Winding calculation can be explained with given input values -> 495.4955 = 15.84/(4.44*24*0.25*0.0012).

FAQ

What is Frequency given EMF Induced in Secondary Winding?
Frequency given EMF Induced in Secondary Winding formula is defined as the number of occurrences of a periodic event per time and is measured in cycles/second. The magnitude of this induced emf can be found by using the following EMF equation of the transformer and is represented as f = E2/(4.44*N2*Acore*Bmax) or Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density). EMF Induced in Secondary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil, The Number of Turns in Secondary Winding is the number of turns secondary winding is the winding of a transformer, Area of Core is defined as the space occupied by the core of a transformer in 2 dimensional space & Maximum Flux Density is defined as the number of lines of force passing through a unit area of material.
How to calculate Frequency given EMF Induced in Secondary Winding?
Frequency given EMF Induced in Secondary Winding formula is defined as the number of occurrences of a periodic event per time and is measured in cycles/second. The magnitude of this induced emf can be found by using the following EMF equation of the transformer is calculated using Supply Frequency = EMF Induced in Secondary/(4.44*Number of Turns in Secondary*Area of Core*Maximum Flux Density). To calculate Frequency given EMF Induced in Secondary Winding, you need EMF Induced in Secondary (E2), Number of Turns in Secondary (N2), Area of Core (Acore) & Maximum Flux Density (Bmax). With our tool, you need to enter the respective value for EMF Induced in Secondary, Number of Turns in Secondary, Area of Core & Maximum Flux Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Supply Frequency?
In this formula, Supply Frequency uses EMF Induced in Secondary, Number of Turns in Secondary, Area of Core & Maximum Flux Density. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Supply Frequency = EMF Induced in Primary/(4.44*Number of Turns in Primary*Area of Core*Maximum Flux Density)
  • Supply Frequency = EMF Induced in Primary/(4.44*Number of Turns in Primary*Area of Core*Maximum Flux Density)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!