Depth of Stiffener Lip Solution

STEP 0: Pre-Calculation Summary
Formula Used
Depth of Stiffener Lip = 2.8*Thickness of Steel Compression Element*((Flat Width Ratio)^2-144)^(1/6)
d = 2.8*t*((wt)^2-144)^(1/6)
This formula uses 3 Variables
Variables Used
Depth of Stiffener Lip - (Measured in Meter) - Depth of Stiffener Lip is the overall distance of the extra lip given for the member in order to stiffen the structure.
Thickness of Steel Compression Element - (Measured in Meter) - The Thickness of Steel Compression Element is the thickness of element or plate.
Flat Width Ratio - Flat Width Ratio is the ratio of width w of a single flat element to the thickness t of the element.
STEP 1: Convert Input(s) to Base Unit
Thickness of Steel Compression Element: 30 Millimeter --> 0.03 Meter (Check conversion ​here)
Flat Width Ratio: 13 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
d = 2.8*t*((wt)^2-144)^(1/6) --> 2.8*0.03*((13)^2-144)^(1/6)
Evaluating ... ...
d = 0.143637979520843
STEP 3: Convert Result to Output's Unit
0.143637979520843 Meter -->143.637979520843 Millimeter (Check conversion ​here)
FINAL ANSWER
143.637979520843 143.638 Millimeter <-- Depth of Stiffener Lip
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Cold Formed or Light Weighted Steel Structures Calculators

Flat Width Ratio of Stiffened Element using Moment of Inertia
​ LaTeX ​ Go Flat Width Ratio = sqrt((Minimum Area Moment of Inertia/(1.83*Thickness of Steel Compression Element^4))^2+144)
Minimum Allowable Moment of Inertia
​ LaTeX ​ Go Minimum Area Moment of Inertia = 1.83*(Thickness of Steel Compression Element^4)*sqrt((Flat Width Ratio^2)-144)
Nominal Strength using Allowable Design Strength
​ LaTeX ​ Go Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength
Allowable Design Strength
​ LaTeX ​ Go Allowable Design Strength = Nominal Strength/Safety Factor for Design Strength

Depth of Stiffener Lip Formula

​LaTeX ​Go
Depth of Stiffener Lip = 2.8*Thickness of Steel Compression Element*((Flat Width Ratio)^2-144)^(1/6)
d = 2.8*t*((wt)^2-144)^(1/6)

What are the types of Cold Form Structures?

The Flat compression elements of cold-formed structural members are classified as stiffened and unstiffened. Stiffened compression elements have both edges parallel to the direction of stress stiffened by a web, flange, or stiffening lip.

How to Calculate Depth of Stiffener Lip?

Depth of Stiffener Lip calculator uses Depth of Stiffener Lip = 2.8*Thickness of Steel Compression Element*((Flat Width Ratio)^2-144)^(1/6) to calculate the Depth of Stiffener Lip, The Depth of Stiffener Lip is defined as the overall depth of simple lip bent at right angles. The performance of unstiffened elements could be substantially improved by introducing stiffeners (such as a lip). Depth of Stiffener Lip is denoted by d symbol.

How to calculate Depth of Stiffener Lip using this online calculator? To use this online calculator for Depth of Stiffener Lip, enter Thickness of Steel Compression Element (t) & Flat Width Ratio (wt) and hit the calculate button. Here is how the Depth of Stiffener Lip calculation can be explained with given input values -> 143638 = 2.8*0.03*((13)^2-144)^(1/6).

FAQ

What is Depth of Stiffener Lip?
The Depth of Stiffener Lip is defined as the overall depth of simple lip bent at right angles. The performance of unstiffened elements could be substantially improved by introducing stiffeners (such as a lip) and is represented as d = 2.8*t*((wt)^2-144)^(1/6) or Depth of Stiffener Lip = 2.8*Thickness of Steel Compression Element*((Flat Width Ratio)^2-144)^(1/6). The Thickness of Steel Compression Element is the thickness of element or plate & Flat Width Ratio is the ratio of width w of a single flat element to the thickness t of the element.
How to calculate Depth of Stiffener Lip?
The Depth of Stiffener Lip is defined as the overall depth of simple lip bent at right angles. The performance of unstiffened elements could be substantially improved by introducing stiffeners (such as a lip) is calculated using Depth of Stiffener Lip = 2.8*Thickness of Steel Compression Element*((Flat Width Ratio)^2-144)^(1/6). To calculate Depth of Stiffener Lip, you need Thickness of Steel Compression Element (t) & Flat Width Ratio (wt). With our tool, you need to enter the respective value for Thickness of Steel Compression Element & Flat Width Ratio and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!