EMF induced in portion below magnetic Field Solution

STEP 0: Pre-Calculation Summary
Formula Used
Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed
emf = B*lf*d*ω
This formula uses 5 Variables
Variables Used
Former EMF - (Measured in Volt) - Former EMF refers to the electrical potential difference or voltage generated by a source such as a battery or a generator.
Magnetic Field - (Measured in Tesla) - Magnetic Field is a region of influence created by moving electric charges, electric currents, or changing electric fields.
Former Length - (Measured in Meter) - Former Length is a fundamental measurement of distance between two points.
Former Breadth - (Measured in Meter) - Former Breadth refers to the distance across the widest part of an object, typically perpendicular to its length or longest dimension.
Former Angular Speed - (Measured in Radian per Second) - Former Angular Speed refers to the rate at which a rotating body covers angular displacement. It is used to quantify how quickly an object is rotating or revolving around a fixed point or axis.
STEP 1: Convert Input(s) to Base Unit
Magnetic Field: 4.75 Tesla --> 4.75 Tesla No Conversion Required
Former Length: 0.2 Meter --> 0.2 Meter No Conversion Required
Former Breadth: 1.2 Meter --> 1.2 Meter No Conversion Required
Former Angular Speed: 10.5 Radian per Second --> 10.5 Radian per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
emf = B*lf*d*ω --> 4.75*0.2*1.2*10.5
Evaluating ... ...
emf = 11.97
STEP 3: Convert Result to Output's Unit
11.97 Volt --> No Conversion Required
FINAL ANSWER
11.97 Volt <-- Former EMF
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Instrument Characteristics Calculators

Magnitude of Output Response
​ LaTeX ​ Go Output Response Magnitude = Sensitivity*Input Response Magnitude
Magnitude of Input
​ LaTeX ​ Go Input Response Magnitude = Output Response Magnitude/Sensitivity
Sensitivity
​ LaTeX ​ Go Sensitivity = Output Response Magnitude/Input Response Magnitude
Inverse Sensitivity or Scale Factor
​ LaTeX ​ Go Inverse Sensitivity = 1/Sensitivity

EMF induced in portion below magnetic Field Formula

​LaTeX ​Go
Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed
emf = B*lf*d*ω

what is difference between SOE and alarms ?

SOE meaning is a Sequence of events. We can find out the region of the trip. As well as we can find the first signal of the trip region. An alarm is an event of process variables like low, high, etc.

How to Calculate EMF induced in portion below magnetic Field?

EMF induced in portion below magnetic Field calculator uses Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed to calculate the Former EMF, EMF induced in portion below magnetic Field formula is defined as the electric potential produced by either an electrochemical cell or by changing the magnetic field. Former EMF is denoted by emf symbol.

How to calculate EMF induced in portion below magnetic Field using this online calculator? To use this online calculator for EMF induced in portion below magnetic Field, enter Magnetic Field (B), Former Length (lf), Former Breadth (d) & Former Angular Speed (ω) and hit the calculate button. Here is how the EMF induced in portion below magnetic Field calculation can be explained with given input values -> 11.97 = 4.75*0.2*1.2*10.5.

FAQ

What is EMF induced in portion below magnetic Field?
EMF induced in portion below magnetic Field formula is defined as the electric potential produced by either an electrochemical cell or by changing the magnetic field and is represented as emf = B*lf*d*ω or Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed. Magnetic Field is a region of influence created by moving electric charges, electric currents, or changing electric fields, Former Length is a fundamental measurement of distance between two points, Former Breadth refers to the distance across the widest part of an object, typically perpendicular to its length or longest dimension & Former Angular Speed refers to the rate at which a rotating body covers angular displacement. It is used to quantify how quickly an object is rotating or revolving around a fixed point or axis.
How to calculate EMF induced in portion below magnetic Field?
EMF induced in portion below magnetic Field formula is defined as the electric potential produced by either an electrochemical cell or by changing the magnetic field is calculated using Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed. To calculate EMF induced in portion below magnetic Field, you need Magnetic Field (B), Former Length (lf), Former Breadth (d) & Former Angular Speed (ω). With our tool, you need to enter the respective value for Magnetic Field, Former Length, Former Breadth & Former Angular Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Former EMF?
In this formula, Former EMF uses Magnetic Field, Former Length, Former Breadth & Former Angular Speed. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Former EMF = Magnetic Field*Former Length*Former Breadth*Former Angular Speed
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!