How to Calculate Effluent BOD given Oxygen Required in Aeration Tank?
Effluent BOD given Oxygen Required in Aeration Tank calculator uses Effluent BOD given Oxygen Required = Influent BOD-((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Flowrate) to calculate the Effluent BOD given Oxygen Required, The Effluent BOD given Oxygen Required in Aeration Tank formula is defined as the concentration of biodegradable organic matter in the treated wastewater that is discharged from an aeration tank in a wastewater treatment plant. The BOD value indicates the amount of oxygen required by microorganisms to decompose this organic matter. When given the oxygen required in an aeration tank, the effluent BOD can be determined as it reflects the efficiency of the biological treatment process. Effluent BOD given Oxygen Required is denoted by Qo symbol.
How to calculate Effluent BOD given Oxygen Required in Aeration Tank using this online calculator? To use this online calculator for Effluent BOD given Oxygen Required in Aeration Tank, enter Influent BOD (Qi), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Flowrate (SF) and hit the calculate button. Here is how the Effluent BOD given Oxygen Required in Aeration Tank calculation can be explained with given input values -> 9422.8 = 0.0132-((3*(2.89351851851852E-11+(1.42*9.5*0.0014)))/15).