Efficiency of torque convertor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller))
η = (ωt/ωp)*(1+(Tv/Tp))
This formula uses 5 Variables
Variables Used
Efficiency of Hydraulic Torque Converter - Efficiency of Hydraulic Torque Converter is the ratio of output power to input power of a hydraulic torque converter in a hydraulic system.
Angular Velocity of Turbine - (Measured in Radian per Second) - Angular velocity of turbine or driven shaft is the speed at which an hydraulic turbine or actually a driven shaft is rotating.
Angular Velocity of Pump - (Measured in Radian per Second) - Angular velocity of pump or the driving shaft is the speed at which an hydraulic pump or actually a driving shaft is rotating.
Variation of Torque - (Measured in Newton Meter) - Variation of Torque is the change in rotational force that occurs in hydraulic components, affecting their performance and efficiency in mechanical systems.
Torque of Pump Impeller - (Measured in Newton Meter) - Torque of Pump Impeller is the rotational force that causes the pump impeller to rotate, generating flow and pressure in hydraulic systems.
STEP 1: Convert Input(s) to Base Unit
Angular Velocity of Turbine: 14 Radian per Second --> 14 Radian per Second No Conversion Required
Angular Velocity of Pump: 16 Radian per Second --> 16 Radian per Second No Conversion Required
Variation of Torque: 1.15 Newton Meter --> 1.15 Newton Meter No Conversion Required
Torque of Pump Impeller: 15.4 Newton Meter --> 15.4 Newton Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
η = (ωtp)*(1+(Tv/Tp)) --> (14/16)*(1+(1.15/15.4))
Evaluating ... ...
η = 0.940340909090909
STEP 3: Convert Result to Output's Unit
0.940340909090909 --> No Conversion Required
FINAL ANSWER
0.940340909090909 0.940341 <-- Efficiency of Hydraulic Torque Converter
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Chilvera Bhanu Teja
Institute of Aeronautical Engineering (IARE), Hyderabad
Chilvera Bhanu Teja has verified this Calculator and 200+ more calculators!

Hydraulic Torque Converter Calculators

Efficiency of torque convertor
​ LaTeX ​ Go Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller))
Hydraulic Torque Convertor - Power Output
​ LaTeX ​ Go Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine
Hydraulic Torque Convertor - Power Input
​ LaTeX ​ Go Input power of hydraulic torque converter = Torque of Pump Impeller*Angular Velocity of Pump
Torque transmitted to turbine shaft of torque converter
​ LaTeX ​ Go Torque transmitted to Turbine Shaft = Torque of Pump Impeller+Variation of Torque

Efficiency of torque convertor Formula

​LaTeX ​Go
Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller))
η = (ωt/ωp)*(1+(Tv/Tp))

What is a Fixed Ram ?

A fixed ram is a component in machinery, such as hydraulic presses or industrial equipment, that provides a stationary, non-moving support or structure for performing tasks like pressing, shaping, or forming materials. It consists of a solid, rigid piece that does not travel during operation, while other moving parts, such as a sliding ram or workpiece, interact with it to complete the process. The fixed ram serves as a stable base or anvil against which the workpiece is pressed or deformed, ensuring precise and controlled operation in various industrial and manufacturing applications.

How to Calculate Efficiency of torque convertor?

Efficiency of torque convertor calculator uses Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller)) to calculate the Efficiency of Hydraulic Torque Converter, Efficiency of torque convertor formula is defined as a measure of the effectiveness of a torque converter in transmitting mechanical power from the engine to the transmission in a hydraulic system, taking into account the turbine and pump speeds, as well as the torque values. Efficiency of Hydraulic Torque Converter is denoted by η symbol.

How to calculate Efficiency of torque convertor using this online calculator? To use this online calculator for Efficiency of torque convertor, enter Angular Velocity of Turbine t), Angular Velocity of Pump p), Variation of Torque (Tv) & Torque of Pump Impeller (Tp) and hit the calculate button. Here is how the Efficiency of torque convertor calculation can be explained with given input values -> 0.940341 = (14/16)*(1+(1.15/15.4)).

FAQ

What is Efficiency of torque convertor?
Efficiency of torque convertor formula is defined as a measure of the effectiveness of a torque converter in transmitting mechanical power from the engine to the transmission in a hydraulic system, taking into account the turbine and pump speeds, as well as the torque values and is represented as η = (ωtp)*(1+(Tv/Tp)) or Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller)). Angular velocity of turbine or driven shaft is the speed at which an hydraulic turbine or actually a driven shaft is rotating, Angular velocity of pump or the driving shaft is the speed at which an hydraulic pump or actually a driving shaft is rotating, Variation of Torque is the change in rotational force that occurs in hydraulic components, affecting their performance and efficiency in mechanical systems & Torque of Pump Impeller is the rotational force that causes the pump impeller to rotate, generating flow and pressure in hydraulic systems.
How to calculate Efficiency of torque convertor?
Efficiency of torque convertor formula is defined as a measure of the effectiveness of a torque converter in transmitting mechanical power from the engine to the transmission in a hydraulic system, taking into account the turbine and pump speeds, as well as the torque values is calculated using Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller)). To calculate Efficiency of torque convertor, you need Angular Velocity of Turbine t), Angular Velocity of Pump p), Variation of Torque (Tv) & Torque of Pump Impeller (Tp). With our tool, you need to enter the respective value for Angular Velocity of Turbine, Angular Velocity of Pump, Variation of Torque & Torque of Pump Impeller and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.