Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
εc = (modulus((Tci-Tco))/(Thi-Tco))
This formula uses 1 Functions, 4 Variables
Functions Used
modulus - Modulus of a number is the remainder when that number is divided by another number., modulus
Variables Used
Effectiveness of HE when Cold Fluid is Min Fluid - Effectiveness of HE when Cold Fluid is Min Fluid depends on Mass flow rate and specific heat, is minimum for cold fluid. HE= Heat Exchanger, Min= Minimum.
Inlet Temperature of Cold Fluid - (Measured in Kelvin) - Inlet Temperature of Cold Fluid is the temperature at which the cold fluid enters the heat exchanger.
Outlet Temperature of Cold Fluid - (Measured in Kelvin) - Outlet Temperature of Cold Fluid is the temperature at which the cold fluid exits the heat exchanger.
Inlet Temperature of Hot Fluid - (Measured in Kelvin) - Inlet Temperature of Hot Fluid is the temperature at which the hot fluid enters the heat exchanger.
STEP 1: Convert Input(s) to Base Unit
Inlet Temperature of Cold Fluid: 283 Kelvin --> 283 Kelvin No Conversion Required
Outlet Temperature of Cold Fluid: 303 Kelvin --> 303 Kelvin No Conversion Required
Inlet Temperature of Hot Fluid: 343 Kelvin --> 343 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
εc = (modulus((Tci-Tco))/(Thi-Tco)) --> (modulus((283-303))/(343-303))
Evaluating ... ...
εc = 0.5
STEP 3: Convert Result to Output's Unit
0.5 --> No Conversion Required
FINAL ANSWER
0.5 <-- Effectiveness of HE when Cold Fluid is Min Fluid
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 900+ more calculators!

Effectiveness of Heat Exchanger Calculators

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid
​ LaTeX ​ Go Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
Effectiveness of Parallel-Flow Heat Exchanger if Cold Fluid is Minimum Fluid
​ LaTeX ​ Go Effectiveness of HE when Cold Fluid is Min Fluid = (Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)
Effectiveness of Parallel-Flow Heat Exchanger if Hot Fluid is Minimum Fluid
​ LaTeX ​ Go Effectiveness of HE when Hot Fluid is Min Fluid = ((Inlet Temperature of Hot Fluid-Outlet Temperature of Hot Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid))
Effectiveness of Counter-Current Heat Exchanger if Hot Fluid is Minimum Fluid
​ LaTeX ​ Go Effectiveness of HE when Hot Fluid is Min Fluid = (Inlet Temperature of Hot Fluid-Outlet Temperature of Hot Fluid)/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)

Heat Exchanger and its Effectiveness Calculators

Heat Transfer in Heat Exchanger given Cold Fluid Properties
​ LaTeX ​ Go Heat = modulus(Mass of Cold Fluid*Specific Heat Capacity of Cold Fluid*(Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))
Heat Transfer in Heat Exchanger given Hot Fluid Properties
​ LaTeX ​ Go Heat = Mass of Hot Fluid*Specific Heat Capacity of Hot Fluid*(Inlet Temperature of Hot Fluid-Outlet Temperature of Hot Fluid)
Fouling Factor
​ LaTeX ​ Go Fouling Factor = (1/Overall Heat Transfer Coefficient after Fouling)-(1/Overall Heat Transfer Coefficient)
Capacity Rate
​ LaTeX ​ Go Capacity Rate = Mass Flow Rate*Specific Heat Capacity

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Formula

​LaTeX ​Go
Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
εc = (modulus((Tci-Tco))/(Thi-Tco))

What is Heat Exchanger?

A Heat Exchanger is a device that facilitates the process of heat exchange between two fluids that are at different temperatures.

What are the different types of Heat Exchanger?

Mainly Heat Exchanger are divided in 4 categories: Hairpin Type Heat Exchanger, Double Pipe Heat Exchanger, Shell and Tube Heat Exchanger & Plate Type Heat Exchanger.

How to Calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid calculator uses Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)) to calculate the Effectiveness of HE when Cold Fluid is Min Fluid, The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 or using modulus is a necessity because effectiveness cannot be negative. Effectiveness of HE when Cold Fluid is Min Fluid is denoted by εc symbol.

How to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid using this online calculator? To use this online calculator for Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid, enter Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi) and hit the calculate button. Here is how the Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid calculation can be explained with given input values -> 0.5 = (modulus((283-303))/(343-303)).

FAQ

What is Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 or using modulus is a necessity because effectiveness cannot be negative and is represented as εc = (modulus((Tci-Tco))/(Thi-Tco)) or Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). Inlet Temperature of Cold Fluid is the temperature at which the cold fluid enters the heat exchanger, Outlet Temperature of Cold Fluid is the temperature at which the cold fluid exits the heat exchanger & Inlet Temperature of Hot Fluid is the temperature at which the hot fluid enters the heat exchanger.
How to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 or using modulus is a necessity because effectiveness cannot be negative is calculated using Effectiveness of HE when Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). To calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid, you need Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi). With our tool, you need to enter the respective value for Inlet Temperature of Cold Fluid, Outlet Temperature of Cold Fluid & Inlet Temperature of Hot Fluid and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Effectiveness of HE when Cold Fluid is Min Fluid?
In this formula, Effectiveness of HE when Cold Fluid is Min Fluid uses Inlet Temperature of Cold Fluid, Outlet Temperature of Cold Fluid & Inlet Temperature of Hot Fluid. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Effectiveness of HE when Cold Fluid is Min Fluid = (Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)
  • Effectiveness of HE when Cold Fluid is Min Fluid = (Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!