Effective Surcharge given Depth of Footing Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing
σs = γ*D
This formula uses 3 Variables
Variables Used
Effective Surcharge in Kilo Pascal - (Measured in Pascal) - Effective Surcharge in Kilo Pascal also called as surcharge load refers to the vertical pressure or any load that acts over the ground surface additional to basic earth pressure.
Unit Weight of Soil - (Measured in Kilonewton per Cubic Meter) - Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil.
Depth of Footing - (Measured in Meter) - Depth of Footing is the vertical distance from the ground surface to the base of a foundation. It is a critical parameter that influences the structural stability of buildings and infrastructure.
STEP 1: Convert Input(s) to Base Unit
Unit Weight of Soil: 18 Kilonewton per Cubic Meter --> 18 Kilonewton per Cubic Meter No Conversion Required
Depth of Footing: 25 Meter --> 25 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
σs = γ*D --> 18*25
Evaluating ... ...
σs = 450
STEP 3: Convert Result to Output's Unit
450 Pascal -->0.45 Kilonewton per Square Meter (Check conversion ​here)
FINAL ANSWER
0.45 Kilonewton per Square Meter <-- Effective Surcharge in Kilo Pascal
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Bearing Capacity of Soils Calculators

Ultimate Bearing Capacity of Soil under Long Footing at Surface of Soil
​ Go Ultimate Bearing Capacity = ((Prandtls Cohesion/tan(Angle of Internal Friction of Soil))+(0.5*Dry Unit Weight of Soil*Width of Footing*sqrt(Coefficient of Passive Pressure))*(Coefficient of Passive Pressure*exp(pi*tan(Angle of Internal Friction of Soil))-1))
Bearing Capacity Factor Dependent on Unit Weight by Vesic's Analysis
​ Go Bearing Capacity Factor dependent on Unit Weight = 2*(Bearing Capacity Factor dependent on Surcharge+1)*tan((Angle of Internal Friction of Soil*pi)/180)
Safe Bearing Capacity given Net Ultimate Bearing Capacity
​ Go Safe Bearing Capacity = (Net Ultimate Bearing Capacity/Factor of Safety in Bearing Capacity of Soil)+(Unit Weight of Soil*Depth of Footing in Soil)
Net Safe Bearing Capacity given Ultimate Bearing Capacity
​ Go Net Safe Bearing Capacity = (Ultimate Bearing Capacity of Soil-Effective Surcharge in Kilo Pascal)/Factor of Safety in Bearing Capacity of Soil
Ultimate Bearing Capacity given Factor of Safety
​ Go Ultimate Bearing Capacity of Soil = (Net Safe Bearing Capacity*Factor of Safety in Bearing Capacity of Soil)+Effective Surcharge in Kilo Pascal
Angle of Internal Friction given Bearing Capacity by Vesic's Analysis
​ Go Angle of Internal Friction = atan(Bearing Capacity Factor dependent on Unit Weight/(2*(Bearing Capacity Factor dependent on Surcharge+1)))
Ultimate Bearing Capacity given Depth of Footing
​ Go Ultimate Bearing Capacity = Net Ultimate Bearing Capacity+(Unit Weight of Soil*Depth of Footing in Soil)
Depth of Footing given Safe Bearing Capacity
​ Go Depth of Footing = (Safe Bearing Capacity of Soil-Net Safe Bearing Capacity in Soil)/Unit Weight of Soil
Safe Bearing Capacity
​ Go Safe Bearing Capacity = Net Safe Bearing Capacity in Soil+(Unit Weight of Soil*Depth of Footing in Soil)
Net Ultimate Bearing Capacity given Net Safe Bearing Capacity
​ Go Net Ultimate Bearing Capacity = Net Safe Bearing Capacity in Soil*Factor of Safety in Bearing Capacity of Soil
Net Safe Bearing Capacity
​ Go Net Safe Bearing Capacity in Soil = Net Ultimate Bearing Capacity/Factor of Safety in Bearing Capacity of Soil
Net Ultimate Bearing Capacity given Ultimate Bearing Capacity
​ Go Net Ultimate Bearing Capacity of Soil = Ultimate Bearing Capacity-Effective Surcharge in Kilo Pascal
Ultimate Bearing Capacity
​ Go Ultimate Bearing Capacity = Net Ultimate Bearing Capacity of Soil+Effective Surcharge in Kilo Pascal
Effective Surcharge given Depth of Footing
​ Go Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing
Effective Surcharge given Net Pressure Intensity
​ Go Effective Surcharge in Kilo Pascal = Gross Pressure-Net Pressure
Net Pressure Intensity
​ Go Net Pressure = Gross Pressure-Effective Surcharge in Kilo Pascal

Effective Surcharge given Depth of Footing Formula

Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing
σs = γ*D

What is Effective Surcharge?

Surcharge is the additional load on the soil which may be created due to any overlying structure or any moving object.

How to Calculate Effective Surcharge given Depth of Footing?

Effective Surcharge given Depth of Footing calculator uses Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing to calculate the Effective Surcharge in Kilo Pascal, The Effective Surcharge given Depth of Footing formula is defined as the additional pressure exerted on the groundwater table due to the presence of a footing or foundation at a certain depth below the ground surface. Effective Surcharge in Kilo Pascal is denoted by σs symbol.

How to calculate Effective Surcharge given Depth of Footing using this online calculator? To use this online calculator for Effective Surcharge given Depth of Footing, enter Unit Weight of Soil (γ) & Depth of Footing (D) and hit the calculate button. Here is how the Effective Surcharge given Depth of Footing calculation can be explained with given input values -> 0.00045 = 18000*25.

FAQ

What is Effective Surcharge given Depth of Footing?
The Effective Surcharge given Depth of Footing formula is defined as the additional pressure exerted on the groundwater table due to the presence of a footing or foundation at a certain depth below the ground surface and is represented as σs = γ*D or Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing. Unit Weight of Soil mass is the ratio of the total weight of soil to the total volume of soil & Depth of Footing is the vertical distance from the ground surface to the base of a foundation. It is a critical parameter that influences the structural stability of buildings and infrastructure.
How to calculate Effective Surcharge given Depth of Footing?
The Effective Surcharge given Depth of Footing formula is defined as the additional pressure exerted on the groundwater table due to the presence of a footing or foundation at a certain depth below the ground surface is calculated using Effective Surcharge in Kilo Pascal = Unit Weight of Soil*Depth of Footing. To calculate Effective Surcharge given Depth of Footing, you need Unit Weight of Soil (γ) & Depth of Footing (D). With our tool, you need to enter the respective value for Unit Weight of Soil & Depth of Footing and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Effective Surcharge in Kilo Pascal?
In this formula, Effective Surcharge in Kilo Pascal uses Unit Weight of Soil & Depth of Footing. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Effective Surcharge in Kilo Pascal = Gross Pressure-Net Pressure
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!