Effective Length of Column given Actual Length if One End is Fixed Other is Free Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effective Length of Column = 2*Length of Column
Le = 2*L
This formula uses 2 Variables
Variables Used
Effective Length of Column - (Measured in Meter) - Effective length of column is the length of an equivalent pin-ended column that has the same load-carrying capacity as the actual column under consideration.
Length of Column - (Measured in Meter) - Length of column refers to the distance between its two ends, a crucial factor in determining the column’s behavior under load, particularly its susceptibility to buckling.
STEP 1: Convert Input(s) to Base Unit
Length of Column: 5000 Millimeter --> 5 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Le = 2*L --> 2*5
Evaluating ... ...
Le = 10
STEP 3: Convert Result to Output's Unit
10 Meter -->10000 Millimeter (Check conversion ​here)
FINAL ANSWER
10000 Millimeter <-- Effective Length of Column
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Estimation of Effective Length of Columns Calculators

Actual Length given Slenderness Ratio
​ LaTeX ​ Go Length of Column = Slenderness Ratio*Least Radius of Gyration of Column
Actual Length of Column given Effective Length if One End is Fixed Other is Hinged
​ LaTeX ​ Go Length of Column = sqrt(2)*Effective Length of Column
Actual Length of Column given Effective Length if One End is Fixed Other is Free
​ LaTeX ​ Go Length of Column = Effective Length of Column/2
Actual Length of Column given Effective Length if Both Ends of Column are Fixed
​ LaTeX ​ Go Length of Column = 2*Effective Length of Column

Effective Length Calculators

Effective Length of Column given Crippling Load for any type of End Condition
​ LaTeX ​ Go Effective Length of Column = sqrt((pi^2*Modulus of Elasticity of Column*Moment of Inertia Column)/(Column Crippling Load))
Effective Length of Column given Actual Length if One End is Fixed Other is Hinged
​ LaTeX ​ Go Effective Length of Column = Length of Column/(sqrt(2))
Effective Length of Column given Actual Length if One End is Fixed Other is Free
​ LaTeX ​ Go Effective Length of Column = 2*Length of Column
Effective Length of Column given Actual Length if Both Ends of Column are Fixed
​ LaTeX ​ Go Effective Length of Column = Length of Column/2

Effective Length of Column given Actual Length if One End is Fixed Other is Free Formula

​LaTeX ​Go
Effective Length of Column = 2*Length of Column
Le = 2*L

What is meant by Effective Length of a Column also define Slenderness Ratio?

The effective length of the column is the length of an equivalent column of the same material and cross-sectional area with hinged ends and having the value of the crippling load equal to that of the given column. The least radius of gyration is the radius of gyration where the least moment of inertia is considered.

How to Calculate Effective Length of Column given Actual Length if One End is Fixed Other is Free?

Effective Length of Column given Actual Length if One End is Fixed Other is Free calculator uses Effective Length of Column = 2*Length of Column to calculate the Effective Length of Column, Effective Length of Column given Actual Length if One End is Fixed Other is Free formula is defined as the length of a column that is equivalent to a fixed-free column, which is used to calculate the buckling load of a column in structural analysis, taking into account the end conditions that affect its stability. Effective Length of Column is denoted by Le symbol.

How to calculate Effective Length of Column given Actual Length if One End is Fixed Other is Free using this online calculator? To use this online calculator for Effective Length of Column given Actual Length if One End is Fixed Other is Free, enter Length of Column (L) and hit the calculate button. Here is how the Effective Length of Column given Actual Length if One End is Fixed Other is Free calculation can be explained with given input values -> 1E+7 = 2*5.

FAQ

What is Effective Length of Column given Actual Length if One End is Fixed Other is Free?
Effective Length of Column given Actual Length if One End is Fixed Other is Free formula is defined as the length of a column that is equivalent to a fixed-free column, which is used to calculate the buckling load of a column in structural analysis, taking into account the end conditions that affect its stability and is represented as Le = 2*L or Effective Length of Column = 2*Length of Column. Length of column refers to the distance between its two ends, a crucial factor in determining the column’s behavior under load, particularly its susceptibility to buckling.
How to calculate Effective Length of Column given Actual Length if One End is Fixed Other is Free?
Effective Length of Column given Actual Length if One End is Fixed Other is Free formula is defined as the length of a column that is equivalent to a fixed-free column, which is used to calculate the buckling load of a column in structural analysis, taking into account the end conditions that affect its stability is calculated using Effective Length of Column = 2*Length of Column. To calculate Effective Length of Column given Actual Length if One End is Fixed Other is Free, you need Length of Column (L). With our tool, you need to enter the respective value for Length of Column and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Effective Length of Column?
In this formula, Effective Length of Column uses Length of Column. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Effective Length of Column = Length of Column/2
  • Effective Length of Column = Length of Column/(sqrt(2))
  • Effective Length of Column = sqrt((pi^2*Modulus of Elasticity of Column*Moment of Inertia Column)/(Column Crippling Load))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!