Effective Conductance of Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effective Conductance in Load = Real Power of Load/RMS Voltage in SVC^2
Geff = Pre/Vn^2
This formula uses 3 Variables
Variables Used
Effective Conductance in Load - (Measured in Siemens) - Effective Conductance in Load is defined as the he equivalent conductance of a complex load in an electrical circuit.
Real Power of Load - (Measured in Watt) - Real Power of Load is defined as the portion of power that performs work, reactive power is associated with the non-working power that flows back and forth between inductive and capacitive elements.
RMS Voltage in SVC - (Measured in Volt) - RMS Voltage in SVC is the voltage at a certain amount of frequency counted at nth harmonic.
STEP 1: Convert Input(s) to Base Unit
Real Power of Load: 440 Watt --> 440 Watt No Conversion Required
RMS Voltage in SVC: 20.2 Volt --> 20.2 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Geff = Pre/Vn^2 --> 440/20.2^2
Evaluating ... ...
Geff = 1.07832565434761
STEP 3: Convert Result to Output's Unit
1.07832565434761 Siemens --> No Conversion Required
FINAL ANSWER
1.07832565434761 1.078326 Siemens <-- Effective Conductance in Load
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Dipanjona Mallick
Heritage Insitute of technology (HITK), Kolkata
Dipanjona Mallick has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Aman Dhussawat
GURU TEGH BAHADUR INSTITUTE OF TECHNOLOGY (GTBIT), NEW DELHI
Aman Dhussawat has verified this Calculator and 100+ more calculators!

AC Transmission Line Analysis Calculators

Phase Constant of Compensated Line
​ LaTeX ​ Go Phase Constant in Compensated Line = Phase Constant in Uncompensated Line*sqrt((1-Degree in Series Compensation)*(1-Degree in Shunt Compensation))
Velocity Propagation in Lossless Line
​ LaTeX ​ Go Velocity Propagation in Lossless Line = 1/sqrt(Series Inductance in Line*Series Capacitance in the Line)
Thevenin's Voltage of Line
​ LaTeX ​ Go Thevenin's Voltage of Line = Sending End Voltage/cos(Electrical Length of Line)
Wavelength Propagation in Lossless Line
​ LaTeX ​ Go Wavelength Propagation in Lossless Line = Velocity Propagation in Lossless Line/Lossless Line Frequency

Effective Conductance of Load Formula

​LaTeX ​Go
Effective Conductance in Load = Real Power of Load/RMS Voltage in SVC^2
Geff = Pre/Vn^2

What is Effective Conductance of Load?

Effective Conductance of Load is defined as the equivalent conductance of a complex load in an electrical circuit, here, Conductance is the reciprocal of resistance, and it is measured in siemens. The term "effective" implies that the load may have a combination of resistive and reactive components, and the effective conductance represents a simplified or equivalent conductance that models the load's behavior.

How to Calculate Effective Conductance of Load?

Effective Conductance of Load calculator uses Effective Conductance in Load = Real Power of Load/RMS Voltage in SVC^2 to calculate the Effective Conductance in Load, The Effective Conductance of Load formula is defined as the equivalent conductance of a complex load in an electrical circuit, this is basically defined as the ratio of real power and the square of rms voltage that is measured in Siemens. Effective Conductance in Load is denoted by Geff symbol.

How to calculate Effective Conductance of Load using this online calculator? To use this online calculator for Effective Conductance of Load, enter Real Power of Load (Pre) & RMS Voltage in SVC (Vn) and hit the calculate button. Here is how the Effective Conductance of Load calculation can be explained with given input values -> 1.078326 = 440/20.2^2.

FAQ

What is Effective Conductance of Load?
The Effective Conductance of Load formula is defined as the equivalent conductance of a complex load in an electrical circuit, this is basically defined as the ratio of real power and the square of rms voltage that is measured in Siemens and is represented as Geff = Pre/Vn^2 or Effective Conductance in Load = Real Power of Load/RMS Voltage in SVC^2. Real Power of Load is defined as the portion of power that performs work, reactive power is associated with the non-working power that flows back and forth between inductive and capacitive elements & RMS Voltage in SVC is the voltage at a certain amount of frequency counted at nth harmonic.
How to calculate Effective Conductance of Load?
The Effective Conductance of Load formula is defined as the equivalent conductance of a complex load in an electrical circuit, this is basically defined as the ratio of real power and the square of rms voltage that is measured in Siemens is calculated using Effective Conductance in Load = Real Power of Load/RMS Voltage in SVC^2. To calculate Effective Conductance of Load, you need Real Power of Load (Pre) & RMS Voltage in SVC (Vn). With our tool, you need to enter the respective value for Real Power of Load & RMS Voltage in SVC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!