Drawdown in Well 1 given Aquifer Constant and Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Drawdown in Well 1 = Drawdown in Well 2+((Discharge)/(2.72*Aquifer Constant))
s1 = s2+((Qw)/(2.72*T))
This formula uses 4 Variables
Variables Used
Drawdown in Well 1 - (Measured in Meter) - Drawdown in Well 1 refers to the reduction in water level caused by pumping in a well.
Drawdown in Well 2 - (Measured in Meter) - Drawdown in Well 2 refers to the reduction in water level caused by pumping in a well.
Discharge - (Measured in Cubic Meter per Second) - Discharge refers to the volume of water that flows through the aquifer over a given period.
Aquifer Constant - Aquifer Constant refers to the product of the hydraulic conductivity (K) and the thickness (b) of an aquifer and also known as coefficient of transmissibility.
STEP 1: Convert Input(s) to Base Unit
Drawdown in Well 2: 2.136 Meter --> 2.136 Meter No Conversion Required
Discharge: 0.911 Cubic Meter per Second --> 0.911 Cubic Meter per Second No Conversion Required
Aquifer Constant: 24.67 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
s1 = s2+((Qw)/(2.72*T)) --> 2.136+((0.911)/(2.72*24.67))
Evaluating ... ...
s1 = 2.14957626552851
STEP 3: Convert Result to Output's Unit
2.14957626552851 Meter --> No Conversion Required
FINAL ANSWER
2.14957626552851 2.149576 Meter <-- Drawdown in Well 1
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Discharge And Drawdown in Well Calculators

Drawdown in Well 1 given Aquifer Constant
​ LaTeX ​ Go Drawdown in Well 1 = Drawdown in Well 2+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant))
Drawdown in Well 2 given Aquifer Constant
​ LaTeX ​ Go Drawdown in Well 2 = Drawdown in Well 1-((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant))
Drawdown in Well 1 given Thickness of Aquifer from Impermeable Layer
​ LaTeX ​ Go Drawdown in Well 1 = Thickness of Aquifer-Depth of Water in Well 1
Drawdown in Well 2 given Thickness of Aquifer from Impermeable Layer
​ LaTeX ​ Go Drawdown in Well 2 = Thickness of Aquifer-Depth of Water in Well 2

Drawdown in Well 1 given Aquifer Constant and Discharge Formula

​LaTeX ​Go
Drawdown in Well 1 = Drawdown in Well 2+((Discharge)/(2.72*Aquifer Constant))
s1 = s2+((Qw)/(2.72*T))

What is Drawdown?

A drawdown is a peak-to-trough decline during a specific period for an investment, trading account, or fund. A drawdown is usually quoted as the percentage between the peak and the subsequent trough.

How to Calculate Drawdown in Well 1 given Aquifer Constant and Discharge?

Drawdown in Well 1 given Aquifer Constant and Discharge calculator uses Drawdown in Well 1 = Drawdown in Well 2+((Discharge)/(2.72*Aquifer Constant)) to calculate the Drawdown in Well 1, Drawdown in Well 1 given Aquifer Constant and Discharge formula is defined as a measure of the decline in water level in a well due to pumping, taking into account the aquifer's properties and the rate of discharge, providing valuable insights into the aquifer's behavior and water availability in confined aquifers. Drawdown in Well 1 is denoted by s1 symbol.

How to calculate Drawdown in Well 1 given Aquifer Constant and Discharge using this online calculator? To use this online calculator for Drawdown in Well 1 given Aquifer Constant and Discharge, enter Drawdown in Well 2 (s2), Discharge (Qw) & Aquifer Constant (T) and hit the calculate button. Here is how the Drawdown in Well 1 given Aquifer Constant and Discharge calculation can be explained with given input values -> 2.151052 = 2.136+((0.911)/(2.72*24.67)).

FAQ

What is Drawdown in Well 1 given Aquifer Constant and Discharge?
Drawdown in Well 1 given Aquifer Constant and Discharge formula is defined as a measure of the decline in water level in a well due to pumping, taking into account the aquifer's properties and the rate of discharge, providing valuable insights into the aquifer's behavior and water availability in confined aquifers and is represented as s1 = s2+((Qw)/(2.72*T)) or Drawdown in Well 1 = Drawdown in Well 2+((Discharge)/(2.72*Aquifer Constant)). Drawdown in Well 2 refers to the reduction in water level caused by pumping in a well, Discharge refers to the volume of water that flows through the aquifer over a given period & Aquifer Constant refers to the product of the hydraulic conductivity (K) and the thickness (b) of an aquifer and also known as coefficient of transmissibility.
How to calculate Drawdown in Well 1 given Aquifer Constant and Discharge?
Drawdown in Well 1 given Aquifer Constant and Discharge formula is defined as a measure of the decline in water level in a well due to pumping, taking into account the aquifer's properties and the rate of discharge, providing valuable insights into the aquifer's behavior and water availability in confined aquifers is calculated using Drawdown in Well 1 = Drawdown in Well 2+((Discharge)/(2.72*Aquifer Constant)). To calculate Drawdown in Well 1 given Aquifer Constant and Discharge, you need Drawdown in Well 2 (s2), Discharge (Qw) & Aquifer Constant (T). With our tool, you need to enter the respective value for Drawdown in Well 2, Discharge & Aquifer Constant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Drawdown in Well 1?
In this formula, Drawdown in Well 1 uses Drawdown in Well 2, Discharge & Aquifer Constant. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Drawdown in Well 1 = Thickness of Aquifer-Depth of Water in Well 1
  • Drawdown in Well 1 = Drawdown in Well 2+((Discharge*log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))/(2.72*Aquifer Constant))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!