Discharge Rate given Height at Outlet Zone with respect to Area of Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge = Falling Speed*Area*Height of Crack/Outer Height
Q = v'*A*h/H
This formula uses 5 Variables
Variables Used
Discharge - (Measured in Cubic Meter per Second) - The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Falling Speed - (Measured in Meter per Second) - The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
Area - (Measured in Square Meter) - The Area of a sedimentation tank refers to the surface area of the tank where sedimentation, or the settling of suspended particles, occurs.
Height of Crack - (Measured in Meter) - The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Outer Height - (Measured in Meter) - The Outer Height refers to the external vertical dimension of an object or structure.
STEP 1: Convert Input(s) to Base Unit
Falling Speed: 0.1 Meter per Second --> 0.1 Meter per Second No Conversion Required
Area: 50 Square Meter --> 50 Square Meter No Conversion Required
Height of Crack: 12000 Millimeter --> 12 Meter (Check conversion ​here)
Outer Height: 40 Meter --> 40 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = v'*A*h/H --> 0.1*50*12/40
Evaluating ... ...
Q = 1.5
STEP 3: Convert Result to Output's Unit
1.5 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
1.5 Cubic Meter per Second <-- Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Discharge Rate Calculators

Discharge Rate given Height at Outlet Zone with respect to Discharge
​ LaTeX ​ Go Discharge = Length*Width*Height of Crack*Falling Speed/Outer Height
Discharge Rate given Detention Time
​ LaTeX ​ Go Discharge = Length*Width*Height of Crack/Detention Time
Discharge Rate given Vertical Falling Speed in Sedimentation Tank
​ LaTeX ​ Go Discharge = Settling Velocity*Length*Width
Discharge Rate given Vertical Falling Speed in Sedimentation Tank with respect to Area
​ LaTeX ​ Go Discharge = Settling Velocity*Area

Discharge Rate given Height at Outlet Zone with respect to Area of Tank Formula

​LaTeX ​Go
Discharge = Falling Speed*Area*Height of Crack/Outer Height
Q = v'*A*h/H

What is Sedimentation?

Sedimentation is the tendency for particles in suspension to settle out of the fluid in which they are entrained and come to rest against a barrier. This is due to their motion through the fluid in response to the forces acting on them: these forces can be due to gravity, centrifugal acceleration, or electromagnetism.

How to Calculate Discharge Rate given Height at Outlet Zone with respect to Area of Tank?

Discharge Rate given Height at Outlet Zone with respect to Area of Tank calculator uses Discharge = Falling Speed*Area*Height of Crack/Outer Height to calculate the Discharge, The Discharge Rate given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of quantity of any fluid flow over unit time. Discharge is denoted by Q symbol.

How to calculate Discharge Rate given Height at Outlet Zone with respect to Area of Tank using this online calculator? To use this online calculator for Discharge Rate given Height at Outlet Zone with respect to Area of Tank, enter Falling Speed (v'), Area (A), Height of Crack (h) & Outer Height (H) and hit the calculate button. Here is how the Discharge Rate given Height at Outlet Zone with respect to Area of Tank calculation can be explained with given input values -> 1.5 = 0.1*50*12/40.

FAQ

What is Discharge Rate given Height at Outlet Zone with respect to Area of Tank?
The Discharge Rate given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of quantity of any fluid flow over unit time and is represented as Q = v'*A*h/H or Discharge = Falling Speed*Area*Height of Crack/Outer Height. The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle, The Area of a sedimentation tank refers to the surface area of the tank where sedimentation, or the settling of suspended particles, occurs, The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress & The Outer Height refers to the external vertical dimension of an object or structure.
How to calculate Discharge Rate given Height at Outlet Zone with respect to Area of Tank?
The Discharge Rate given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of quantity of any fluid flow over unit time is calculated using Discharge = Falling Speed*Area*Height of Crack/Outer Height. To calculate Discharge Rate given Height at Outlet Zone with respect to Area of Tank, you need Falling Speed (v'), Area (A), Height of Crack (h) & Outer Height (H). With our tool, you need to enter the respective value for Falling Speed, Area, Height of Crack & Outer Height and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge?
In this formula, Discharge uses Falling Speed, Area, Height of Crack & Outer Height. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Discharge = Settling Velocity*Length*Width
  • Discharge = Settling Velocity*Area
  • Discharge = Length*Width*Height of Crack/Detention Time
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!