Discharge per unit width of aquifers Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness
q = ((ho-h1)/Lstream)*k*b
This formula uses 6 Variables
Variables Used
Discharge per Unit Width of Aquifer - (Measured in Cubic Meter per Second) - The Discharge per Unit Width of Aquifer refers to the rate of total discharge in the channel to the width considered.
Piezometric Head at Upstream End - (Measured in Meter) - The Piezometric Head at Upstream End refers to the specific measurement of liquid pressure above a vertical datum.
Piezometric Head at Downstream End - (Measured in Meter) - The Piezometric Head at Downstream End refers to the specific measurement of liquid pressure above a vertical datum.
Length between Upstream and Downstream - (Measured in Meter) - The Length between Upstream and Downstream refers to the horizontal base with a difference in surface elevations.
Coefficient of Permeability - (Measured in Meter per Second) - The Coefficient of Permeability refers to the rate of flow of water under laminar flow conditions through a unit cross-sectional area of a porous medium under a unit hydraulic gradient.
Aquifer Thickness - (Measured in Meter) - The Aquifer Thickness is referred as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters.
STEP 1: Convert Input(s) to Base Unit
Piezometric Head at Upstream End: 12 Meter --> 12 Meter No Conversion Required
Piezometric Head at Downstream End: 5 Meter --> 5 Meter No Conversion Required
Length between Upstream and Downstream: 4.09 Meter --> 4.09 Meter No Conversion Required
Coefficient of Permeability: 0.5 Meter per Second --> 0.5 Meter per Second No Conversion Required
Aquifer Thickness: 35 Meter --> 35 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
q = ((ho-h1)/Lstream)*k*b --> ((12-5)/4.09)*0.5*35
Evaluating ... ...
q = 29.9511002444988
STEP 3: Convert Result to Output's Unit
29.9511002444988 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
29.9511002444988 29.9511 Cubic Meter per Second <-- Discharge per Unit Width of Aquifer
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Confined Groundwater Flow between Water Bodies Calculators

Coefficient of Permeability when Discharge is Considered
​ LaTeX ​ Go Coefficient of Permeability = Discharge per Unit Width of Aquifer*Length between Upstream and Downstream/((Piezometric Head at Upstream End-Piezometric Head at Downstream End)*Aquifer Thickness)
Aquifer Thickness when Discharge is Considered
​ LaTeX ​ Go Aquifer Thickness = Discharge per Unit Width of Aquifer*Length between Upstream and Downstream/((Piezometric Head at Upstream End-Piezometric Head at Downstream End)*Coefficient of Permeability)
Discharge per unit width of aquifers
​ LaTeX ​ Go Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness
Equation of Hydraulic Grade Line in Confined Groundwater Flow
​ LaTeX ​ Go Piezometric Head = Piezometric Head at Upstream End-((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Flow in 'x' Direction

Discharge per unit width of aquifers Formula

​LaTeX ​Go
Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness
q = ((ho-h1)/Lstream)*k*b

What is Head in hydrology?

In fluid dynamics, head is a concept that relates the energy in an incompressible fluid to the height of an equivalent static column of that fluid. Velocity head is due to the bulk motion of a fluid (kinetic energy). Its pressure head correspondent is the dynamic pressure

How to Calculate Discharge per unit width of aquifers?

Discharge per unit width of aquifers calculator uses Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness to calculate the Discharge per Unit Width of Aquifer, The Discharge per Unit Width of Aquifers formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area. Discharge per Unit Width of Aquifer is denoted by q symbol.

How to calculate Discharge per unit width of aquifers using this online calculator? To use this online calculator for Discharge per unit width of aquifers, enter Piezometric Head at Upstream End (ho), Piezometric Head at Downstream End (h1), Length between Upstream and Downstream (Lstream), Coefficient of Permeability (k) & Aquifer Thickness (b) and hit the calculate button. Here is how the Discharge per unit width of aquifers calculation can be explained with given input values -> 12.83619 = ((12-5)/4.09)*0.5*35.

FAQ

What is Discharge per unit width of aquifers?
The Discharge per Unit Width of Aquifers formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area and is represented as q = ((ho-h1)/Lstream)*k*b or Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness. The Piezometric Head at Upstream End refers to the specific measurement of liquid pressure above a vertical datum, The Piezometric Head at Downstream End refers to the specific measurement of liquid pressure above a vertical datum, The Length between Upstream and Downstream refers to the horizontal base with a difference in surface elevations, The Coefficient of Permeability refers to the rate of flow of water under laminar flow conditions through a unit cross-sectional area of a porous medium under a unit hydraulic gradient & The Aquifer Thickness is referred as vertical distance between the top and bottom boundaries of an aquifer, typically measured in feet or meters.
How to calculate Discharge per unit width of aquifers?
The Discharge per Unit Width of Aquifers formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area is calculated using Discharge per Unit Width of Aquifer = ((Piezometric Head at Upstream End-Piezometric Head at Downstream End)/Length between Upstream and Downstream)*Coefficient of Permeability*Aquifer Thickness. To calculate Discharge per unit width of aquifers, you need Piezometric Head at Upstream End (ho), Piezometric Head at Downstream End (h1), Length between Upstream and Downstream (Lstream), Coefficient of Permeability (k) & Aquifer Thickness (b). With our tool, you need to enter the respective value for Piezometric Head at Upstream End, Piezometric Head at Downstream End, Length between Upstream and Downstream, Coefficient of Permeability & Aquifer Thickness and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge per Unit Width of Aquifer?
In this formula, Discharge per Unit Width of Aquifer uses Piezometric Head at Upstream End, Piezometric Head at Downstream End, Length between Upstream and Downstream, Coefficient of Permeability & Aquifer Thickness. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Discharge per Unit Width of Aquifer = Cross-Sectional Area*Groundwater Velocity
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!