How to Calculate Discharge Passing through Vertical Section of Infiltration Gallery?
Discharge Passing through Vertical Section of Infiltration Gallery calculator uses Discharge = (Coefficient of Permeability*((Height of Saturated Zone)^2-(Depth of Water in Infiltration Gallery)^2))/(2*Distance Between IG and Source) to calculate the Discharge, The Discharge Passing through Vertical Section of Infiltration Gallery is defined as the value of discharge passing through the vertical section when we have prior information of other parameters used. Discharge is denoted by Q symbol.
How to calculate Discharge Passing through Vertical Section of Infiltration Gallery using this online calculator? To use this online calculator for Discharge Passing through Vertical Section of Infiltration Gallery, enter Coefficient of Permeability (k), Height of Saturated Zone (H), Depth of Water in Infiltration Gallery (Ho) & Distance Between IG and Source (L) and hit the calculate button. Here is how the Discharge Passing through Vertical Section of Infiltration Gallery calculation can be explained with given input values -> 1.008532 = (0.1*((17.55)^2-(10.31)^2))/(2*10).