Discharge for Partially Penetrating Well given Correction Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge for Partially Penetrating Well = Correction Factor*Discharge for Fully Penetrating Gravity Well
Qv = G*Qfe
This formula uses 3 Variables
Variables Used
Discharge for Partially Penetrating Well - (Measured in Cubic Meter per Second) - Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Correction Factor - Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
Discharge for Fully Penetrating Gravity Well - (Measured in Cubic Meter per Second) - Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
STEP 1: Convert Input(s) to Base Unit
Correction Factor: 0.83 --> No Conversion Required
Discharge for Fully Penetrating Gravity Well: 6.12 Cubic Meter per Second --> 6.12 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qv = G*Qfe --> 0.83*6.12
Evaluating ... ...
Qv = 5.0796
STEP 3: Convert Result to Output's Unit
5.0796 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
5.0796 Cubic Meter per Second <-- Discharge for Partially Penetrating Well
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Partially Penetrating Artesian Well Calculators

Coefficient of Permeability given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Coefficient of Permeability = Discharge for Partially Penetrating Well/((2*pi*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Aquifer Thickness given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Thickness of Aquifer given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Initial Piezometric Surface = Depth of Water+(Discharge for Partially Penetrating Well*(log((Radius of Influence/Radius of Well),e)))/(2*pi*Coefficient of Permeability*Aquifer Thickness*Correction Factor)
Discharge for Partially Penetrating Well
​ LaTeX ​ Go Discharge for Partially Penetrating Well = (2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))

Discharge for Partially Penetrating Well given Correction Factor Formula

​LaTeX ​Go
Discharge for Partially Penetrating Well = Correction Factor*Discharge for Fully Penetrating Gravity Well
Qv = G*Qfe

What is Correction Factor?

The correction factor in a partially penetrating well accounts for the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness. This factor adjusts the discharge calculation to reflect the limited interaction with the aquifer, incorporating vertical flow components and head losses. It helps in accurately estimating the well's discharge by compensating for deviations from the ideal flow assumed in fully penetrating wells.

How to Calculate Discharge for Partially Penetrating Well given Correction Factor?

Discharge for Partially Penetrating Well given Correction Factor calculator uses Discharge for Partially Penetrating Well = Correction Factor*Discharge for Fully Penetrating Gravity Well to calculate the Discharge for Partially Penetrating Well, Discharge for Partially Penetrating Well given Correction Factor formula is defined as a measure of the volumetric flow rate of a partially penetrating well, taking into account the correction factor that adjusts for the well's partial penetration into the aquifer, providing a more accurate representation of the well's discharge capacity in various flow conditions. Discharge for Partially Penetrating Well is denoted by Qv symbol.

How to calculate Discharge for Partially Penetrating Well given Correction Factor using this online calculator? To use this online calculator for Discharge for Partially Penetrating Well given Correction Factor, enter Correction Factor (G) & Discharge for Fully Penetrating Gravity Well (Qfe) and hit the calculate button. Here is how the Discharge for Partially Penetrating Well given Correction Factor calculation can be explained with given input values -> 0.000415 = 0.83*6.12.

FAQ

What is Discharge for Partially Penetrating Well given Correction Factor?
Discharge for Partially Penetrating Well given Correction Factor formula is defined as a measure of the volumetric flow rate of a partially penetrating well, taking into account the correction factor that adjusts for the well's partial penetration into the aquifer, providing a more accurate representation of the well's discharge capacity in various flow conditions and is represented as Qv = G*Qfe or Discharge for Partially Penetrating Well = Correction Factor*Discharge for Fully Penetrating Gravity Well. Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness & Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
How to calculate Discharge for Partially Penetrating Well given Correction Factor?
Discharge for Partially Penetrating Well given Correction Factor formula is defined as a measure of the volumetric flow rate of a partially penetrating well, taking into account the correction factor that adjusts for the well's partial penetration into the aquifer, providing a more accurate representation of the well's discharge capacity in various flow conditions is calculated using Discharge for Partially Penetrating Well = Correction Factor*Discharge for Fully Penetrating Gravity Well. To calculate Discharge for Partially Penetrating Well given Correction Factor, you need Correction Factor (G) & Discharge for Fully Penetrating Gravity Well (Qfe). With our tool, you need to enter the respective value for Correction Factor & Discharge for Fully Penetrating Gravity Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge for Partially Penetrating Well?
In this formula, Discharge for Partially Penetrating Well uses Correction Factor & Discharge for Fully Penetrating Gravity Well. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Discharge for Partially Penetrating Well = (2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!