Discharge for Fully Penetrating Well given Correction Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor
Qfe = Qv/G
This formula uses 3 Variables
Variables Used
Discharge for Fully Penetrating Gravity Well - (Measured in Cubic Meter per Second) - Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
Discharge for Partially Penetrating Well - (Measured in Cubic Meter per Second) - Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Correction Factor - Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
STEP 1: Convert Input(s) to Base Unit
Discharge for Partially Penetrating Well: 5.08 Cubic Meter per Second --> 5.08 Cubic Meter per Second No Conversion Required
Correction Factor: 0.83 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qfe = Qv/G --> 5.08/0.83
Evaluating ... ...
Qfe = 6.12048192771084
STEP 3: Convert Result to Output's Unit
6.12048192771084 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
6.12048192771084 6.120482 Cubic Meter per Second <-- Discharge for Fully Penetrating Gravity Well
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Partially Penetrating Artesian Well Calculators

Coefficient of Permeability given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Coefficient of Permeability = Discharge for Partially Penetrating Well/((2*pi*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Aquifer Thickness given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Thickness of Aquifer given Discharge for Partially Penetrating Well
​ LaTeX ​ Go Initial Piezometric Surface = Depth of Water+(Discharge for Partially Penetrating Well*(log((Radius of Influence/Radius of Well),e)))/(2*pi*Coefficient of Permeability*Aquifer Thickness*Correction Factor)
Discharge for Partially Penetrating Well
​ LaTeX ​ Go Discharge for Partially Penetrating Well = (2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))

Discharge for Fully Penetrating Well given Correction Factor Formula

​LaTeX ​Go
Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor
Qfe = Qv/G

What is Discharge?

The amount of fluid passing a section of a stream in unit time is called the discharge. If v is the mean velocity and A is the cross sectional area, the discharge Q is defined by Q = Av which is known as volume flow rate.

How to Calculate Discharge for Fully Penetrating Well given Correction Factor?

Discharge for Fully Penetrating Well given Correction Factor calculator uses Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor to calculate the Discharge for Fully Penetrating Gravity Well, Discharge for Fully Penetrating Well given Correction Factor formula is defined as a method to determine the effective discharge of a fully penetrating well in a confined aquifer, taking into account the correction factor that affects the well's discharge rate, which is essential in understanding groundwater flow and management. Discharge for Fully Penetrating Gravity Well is denoted by Qfe symbol.

How to calculate Discharge for Fully Penetrating Well given Correction Factor using this online calculator? To use this online calculator for Discharge for Fully Penetrating Well given Correction Factor, enter Discharge for Partially Penetrating Well (Qv) & Correction Factor (G) and hit the calculate button. Here is how the Discharge for Fully Penetrating Well given Correction Factor calculation can be explained with given input values -> 6.120482 = 5.08/0.83.

FAQ

What is Discharge for Fully Penetrating Well given Correction Factor?
Discharge for Fully Penetrating Well given Correction Factor formula is defined as a method to determine the effective discharge of a fully penetrating well in a confined aquifer, taking into account the correction factor that affects the well's discharge rate, which is essential in understanding groundwater flow and management and is represented as Qfe = Qv/G or Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor. Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer & Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
How to calculate Discharge for Fully Penetrating Well given Correction Factor?
Discharge for Fully Penetrating Well given Correction Factor formula is defined as a method to determine the effective discharge of a fully penetrating well in a confined aquifer, taking into account the correction factor that affects the well's discharge rate, which is essential in understanding groundwater flow and management is calculated using Discharge for Fully Penetrating Gravity Well = Discharge for Partially Penetrating Well/Correction Factor. To calculate Discharge for Fully Penetrating Well given Correction Factor, you need Discharge for Partially Penetrating Well (Qv) & Correction Factor (G). With our tool, you need to enter the respective value for Discharge for Partially Penetrating Well & Correction Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!