Dicken's Formula for Maximum Flood Discharge in Central India Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Flood Discharge = Dicken's Constant for Central lndian*Catchment Area^(3/4)
Qmp = CCI*A^(3/4)
This formula uses 3 Variables
Variables Used
Maximum Flood Discharge - (Measured in Cubic Meter per Second) - Maximum Flood discharge is the maximum volume flow rate passing through a particular location during an event.
Dicken's Constant for Central lndian - Dicken's Constant for Central lndian is a factor used in meteorology, representing the monthly mean of maximum temperature minus the monthly mean of minimum temperature.
Catchment Area - (Measured in Square Kilometer) - Catchment Area for an empirical estimation is in square kilometers to where all water flows to a single stream, river, lake or even ocean.
STEP 1: Convert Input(s) to Base Unit
Dicken's Constant for Central lndian: 25 --> No Conversion Required
Catchment Area: 40.5 Square Kilometer --> 40.5 Square Kilometer No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qmp = CCI*A^(3/4) --> 25*40.5^(3/4)
Evaluating ... ...
Qmp = 401.357401313418
STEP 3: Convert Result to Output's Unit
401.357401313418 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
401.357401313418 401.3574 Cubic Meter per Second <-- Maximum Flood Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rachana B V
The National Institute of Engineering (NIE), Mysuru
Rachana B V has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Ayush Singh
Gautam Buddha University (GBU), Greater Noida
Ayush Singh has verified this Calculator and 100+ more calculators!

Dicken's Formula (1865) Calculators

Dicken's Formula for Maximum Flood Discharge in North-Indian Hilly Regions
​ LaTeX ​ Go Maximum Flood Discharge = Dickens's Constant for North India hilly regions*Catchment Area^(3/4)
Catchment area when maximum flood discharge is considered in Dickens formula
​ LaTeX ​ Go Catchment Area = (Maximum Flood Discharge/Dicken's Constant)^(1/0.75)
Dicken's Formula for maximum flood discharge
​ LaTeX ​ Go Maximum Flood Discharge = Dicken's Constant*Catchment Area^(3/4)
Dicken's Formula for Maximum Flood Discharge in North-Indian Plains
​ LaTeX ​ Go Maximum Flood Discharge = 6*Catchment Area^(3/4)

Dicken's Formula for Maximum Flood Discharge in Central India Formula

​LaTeX ​Go
Maximum Flood Discharge = Dicken's Constant for Central lndian*Catchment Area^(3/4)
Qmp = CCI*A^(3/4)

What is Catchment Area?

A catchment area is an area from which surface runoff is carried away by a single drainage system. The area of land bounded by watersheds draining into a river, basin or reservoir.

What is Maximum Food Discharge?

In Hydrology, the term “peak discharge” stands for the highest concentration of runoff from the basin area. The concentrated flow of the basin greatly exaggerates and overtops the natural or artificial bank, and this might be called a flood.

How to Calculate Dicken's Formula for Maximum Flood Discharge in Central India?

Dicken's Formula for Maximum Flood Discharge in Central India calculator uses Maximum Flood Discharge = Dicken's Constant for Central lndian*Catchment Area^(3/4) to calculate the Maximum Flood Discharge, The Dicken's Formula for Maximum Flood Discharge in Central India formula is defined as an empirical equation used to estimate peak flood flow, integrating basin characteristics to predict maximum flood discharge in the region. Maximum Flood Discharge is denoted by Qmp symbol.

How to calculate Dicken's Formula for Maximum Flood Discharge in Central India using this online calculator? To use this online calculator for Dicken's Formula for Maximum Flood Discharge in Central India, enter Dicken's Constant for Central lndian (CCI) & Catchment Area (A) and hit the calculate button. Here is how the Dicken's Formula for Maximum Flood Discharge in Central India calculation can be explained with given input values -> 401.3574 = 25*40500000^(3/4).

FAQ

What is Dicken's Formula for Maximum Flood Discharge in Central India?
The Dicken's Formula for Maximum Flood Discharge in Central India formula is defined as an empirical equation used to estimate peak flood flow, integrating basin characteristics to predict maximum flood discharge in the region and is represented as Qmp = CCI*A^(3/4) or Maximum Flood Discharge = Dicken's Constant for Central lndian*Catchment Area^(3/4). Dicken's Constant for Central lndian is a factor used in meteorology, representing the monthly mean of maximum temperature minus the monthly mean of minimum temperature & Catchment Area for an empirical estimation is in square kilometers to where all water flows to a single stream, river, lake or even ocean.
How to calculate Dicken's Formula for Maximum Flood Discharge in Central India?
The Dicken's Formula for Maximum Flood Discharge in Central India formula is defined as an empirical equation used to estimate peak flood flow, integrating basin characteristics to predict maximum flood discharge in the region is calculated using Maximum Flood Discharge = Dicken's Constant for Central lndian*Catchment Area^(3/4). To calculate Dicken's Formula for Maximum Flood Discharge in Central India, you need Dicken's Constant for Central lndian (CCI) & Catchment Area (A). With our tool, you need to enter the respective value for Dicken's Constant for Central lndian & Catchment Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Flood Discharge?
In this formula, Maximum Flood Discharge uses Dicken's Constant for Central lndian & Catchment Area. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Maximum Flood Discharge = Dicken's Constant*Catchment Area^(3/4)
  • Maximum Flood Discharge = 6*Catchment Area^(3/4)
  • Maximum Flood Discharge = Dickens's Constant for North India hilly regions*Catchment Area^(3/4)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!