How to Calculate Diameter of Valve Head given Load on Exhaust Valve and Back Pressure?
Diameter of Valve Head given Load on Exhaust Valve and Back Pressure calculator uses Diameter of Valve Head = sqrt((4*Gas Load on Exhaust Valve)/(pi*Back Pressure on Engine Valve)) to calculate the Diameter of Valve Head, Diameter of valve head given load on exhaust valve and back pressure is the diameter of the top part of valve of an IC engine, valve intakes, and exhausts gases to and from an engine. Diameter of Valve Head is denoted by dv symbol.
How to calculate Diameter of Valve Head given Load on Exhaust Valve and Back Pressure using this online calculator? To use this online calculator for Diameter of Valve Head given Load on Exhaust Valve and Back Pressure, enter Gas Load on Exhaust Valve (Pg) & Back Pressure on Engine Valve (Pb) and hit the calculate button. Here is how the Diameter of Valve Head given Load on Exhaust Valve and Back Pressure calculation can be explained with given input values -> 51708.83 = sqrt((4*1680)/(pi*800000)).