Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula Solution

STEP 0: Pre-Calculation Summary
Formula Used
Diameter of Pipe = ((Flow Velocity*Manning Coefficient)/(0.397*(Hydraulic Gradient^(1/2))))^(3/2)
Dp = ((vf*n)/(0.397*(S^(1/2))))^(3/2)
This formula uses 4 Variables
Variables Used
Diameter of Pipe - (Measured in Meter) - Diameter of Pipe is the diameter of the pipe in which the liquid is flowing.
Flow Velocity - (Measured in Meter per Second) - Flow Velocity refers to the speed at which a fluid, such as a liquid or gas, moves through a particular area within a given time.
Manning Coefficient - Manning Coefficient is dimensionless and varies depending on the type of channel or surface through which water flows.
Hydraulic Gradient - Hydraulic Gradient is a specific measurement of liquid pressure above a vertical datum.
STEP 1: Convert Input(s) to Base Unit
Flow Velocity: 11.96 Meter per Second --> 11.96 Meter per Second No Conversion Required
Manning Coefficient: 0.009 --> No Conversion Required
Hydraulic Gradient: 0.25 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Dp = ((vf*n)/(0.397*(S^(1/2))))^(3/2) --> ((11.96*0.009)/(0.397*(0.25^(1/2))))^(3/2)
Evaluating ... ...
Dp = 0.399318808874582
STEP 3: Convert Result to Output's Unit
0.399318808874582 Meter --> No Conversion Required
FINAL ANSWER
0.399318808874582 0.399319 Meter <-- Diameter of Pipe
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Manning's Formula Calculators

Velocity of Flow in Pipe by Manning Formula
​ LaTeX ​ Go Flow Velocity = (1/Manning Coefficient)*(Hydraulic Radius^(2/3))*(Hydraulic Gradient^(1/2))
Radius of Pipe given Velocity of Flow in Pipe by Manning Formula
​ LaTeX ​ Go Hydraulic Radius = ((Flow Velocity*Manning Coefficient)/(Hydraulic Gradient^(1/2)))^(3/2)
Manning's Coefficient given Velocity of Flow
​ LaTeX ​ Go Manning Coefficient = ((Hydraulic Radius^(2/3))*(Hydraulic Gradient^(1/2)))/Flow Velocity
Hydraulic Gradient given Velocity of Flow in Pipe by Manning Formula
​ LaTeX ​ Go Hydraulic Gradient = ((Flow Velocity*Manning Coefficient)/(Hydraulic Radius^(2/3)))^2

Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula Formula

​LaTeX ​Go
Diameter of Pipe = ((Flow Velocity*Manning Coefficient)/(0.397*(Hydraulic Gradient^(1/2))))^(3/2)
Dp = ((vf*n)/(0.397*(S^(1/2))))^(3/2)

What is Flow Velocity ?

Flow velocity refers to the speed at which a fluid, such as a liquid or gas, moves through a particular area within a given time.

How to Calculate Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula?

Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula calculator uses Diameter of Pipe = ((Flow Velocity*Manning Coefficient)/(0.397*(Hydraulic Gradient^(1/2))))^(3/2) to calculate the Diameter of Pipe, The Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula is defined as the value of diameter of pipe when we have prior information of velocity of flow in pipe. Diameter of Pipe is denoted by Dp symbol.

How to calculate Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula using this online calculator? To use this online calculator for Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula, enter Flow Velocity (vf), Manning Coefficient (n) & Hydraulic Gradient (S) and hit the calculate button. Here is how the Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula calculation can be explained with given input values -> 0.399319 = ((11.96*0.009)/(0.397*(0.25^(1/2))))^(3/2).

FAQ

What is Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula?
The Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula is defined as the value of diameter of pipe when we have prior information of velocity of flow in pipe and is represented as Dp = ((vf*n)/(0.397*(S^(1/2))))^(3/2) or Diameter of Pipe = ((Flow Velocity*Manning Coefficient)/(0.397*(Hydraulic Gradient^(1/2))))^(3/2). Flow Velocity refers to the speed at which a fluid, such as a liquid or gas, moves through a particular area within a given time, Manning Coefficient is dimensionless and varies depending on the type of channel or surface through which water flows & Hydraulic Gradient is a specific measurement of liquid pressure above a vertical datum.
How to calculate Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula?
The Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula is defined as the value of diameter of pipe when we have prior information of velocity of flow in pipe is calculated using Diameter of Pipe = ((Flow Velocity*Manning Coefficient)/(0.397*(Hydraulic Gradient^(1/2))))^(3/2). To calculate Diameter of Pipe given Velocity of Flow in Pipe by Manning Formula, you need Flow Velocity (vf), Manning Coefficient (n) & Hydraulic Gradient (S). With our tool, you need to enter the respective value for Flow Velocity, Manning Coefficient & Hydraulic Gradient and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Diameter of Pipe?
In this formula, Diameter of Pipe uses Flow Velocity, Manning Coefficient & Hydraulic Gradient. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Diameter of Pipe = ((Pipe Length*(Manning Coefficient*Flow Velocity)^2)/(0.157*Head Loss))^(3/4)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!