Design Surface Loading Rate given Surface Area of Circular Settling Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Surface Loading Rate = (Peak Discharge/Surface Area)
Sl = (Qp/SA)
This formula uses 3 Variables
Variables Used
Surface Loading Rate - (Measured in Kilogram per Second Square Meter) - Surface Loading Rate is the volume of liquid applied per unit surface area of a treatment process, such as a clarifier.
Peak Discharge - (Measured in Cubic Meter per Second) - Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Surface Area - (Measured in Square Meter) - Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
STEP 1: Convert Input(s) to Base Unit
Peak Discharge: 37.5 Million Liters per Day --> 0.434027777777778 Cubic Meter per Second (Check conversion ​here)
Surface Area: 4 Square Meter --> 4 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Sl = (Qp/SA) --> (0.434027777777778/4)
Evaluating ... ...
Sl = 0.108506944444445
STEP 3: Convert Result to Output's Unit
0.108506944444445 Kilogram per Second Square Meter --> No Conversion Required
FINAL ANSWER
0.108506944444445 0.108507 Kilogram per Second Square Meter <-- Surface Loading Rate
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Circular Settling Tank Calculators

Design Surface Loading Rate given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Loading Rate = (Peak Discharge/Surface Area)
Peak Discharge given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Peak Discharge = (Surface Area*Surface Loading Rate)
Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Area = (Peak Discharge/Surface Loading Rate)
Peak Discharge in Circular Settling Tanks
​ LaTeX ​ Go Peak Discharge = Average Daily Load*Peaking Factor

Design Surface Loading Rate given Surface Area of Circular Settling Tank Formula

​LaTeX ​Go
Surface Loading Rate = (Peak Discharge/Surface Area)
Sl = (Qp/SA)

What is Surface Loading Rate?

The Surface Loading Rate is the number of gallons of wastewater passing over 1 ft2 of tank per day. This can be used to compare actual conditions with design. Plant designs generally use a surface loading rate of 300 to 1200 gpd/ft2.

How to Calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank?

Design Surface Loading Rate given Surface Area of Circular Settling Tank calculator uses Surface Loading Rate = (Peak Discharge/Surface Area) to calculate the Surface Loading Rate, The Design Surface Loading Rate given Surface Area of Circular Settling Tank is defined as rate at which wastewater can be applied to the surface area of the circular settling tank, typically expressed in units such as (L/s/m²) or (m³/h/m²), based on the tank's design specifications and hydraulic capacity. Surface Loading Rate is denoted by Sl symbol.

How to calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank using this online calculator? To use this online calculator for Design Surface Loading Rate given Surface Area of Circular Settling Tank, enter Peak Discharge (Qp) & Surface Area (SA) and hit the calculate button. Here is how the Design Surface Loading Rate given Surface Area of Circular Settling Tank calculation can be explained with given input values -> 0.108507 = (0.434027777777778/4).

FAQ

What is Design Surface Loading Rate given Surface Area of Circular Settling Tank?
The Design Surface Loading Rate given Surface Area of Circular Settling Tank is defined as rate at which wastewater can be applied to the surface area of the circular settling tank, typically expressed in units such as (L/s/m²) or (m³/h/m²), based on the tank's design specifications and hydraulic capacity and is represented as Sl = (Qp/SA) or Surface Loading Rate = (Peak Discharge/Surface Area). Peak Discharge is the maximum volume flow rate passing a particular location during an event & Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
How to calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank?
The Design Surface Loading Rate given Surface Area of Circular Settling Tank is defined as rate at which wastewater can be applied to the surface area of the circular settling tank, typically expressed in units such as (L/s/m²) or (m³/h/m²), based on the tank's design specifications and hydraulic capacity is calculated using Surface Loading Rate = (Peak Discharge/Surface Area). To calculate Design Surface Loading Rate given Surface Area of Circular Settling Tank, you need Peak Discharge (Qp) & Surface Area (SA). With our tool, you need to enter the respective value for Peak Discharge & Surface Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.