Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present Solution

STEP 0: Pre-Calculation Summary
Formula Used
Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303)
hdp = hw1/10^((0.25*t/3600)/2.303)
This formula uses 3 Variables
Variables Used
Depression Head after Pumping Stopped - (Measured in Meter) - Depression Head after Pumping Stopped is the reduction in the water table or piezometric surface that remains after pumping has ceased.
Depression Head in Well 1 - (Measured in Meter) - Depression Head in Well 1 is the depression head in the well when pumping stopped.
Time - (Measured in Second) - Time refers to the ongoing and continuous sequence of events that occur in succession, from the past through the present to the future.
STEP 1: Convert Input(s) to Base Unit
Depression Head in Well 1: 3 Meter --> 3 Meter No Conversion Required
Time: 4 Hour --> 14400 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hdp = hw1/10^((0.25*t/3600)/2.303) --> 3/10^((0.25*14400/3600)/2.303)
Evaluating ... ...
hdp = 1.10383717219999
STEP 3: Convert Result to Output's Unit
1.10383717219999 Meter --> No Conversion Required
FINAL ANSWER
1.10383717219999 1.103837 Meter <-- Depression Head after Pumping Stopped
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Depression Head after Pumping Stopped Calculators

Depression Head in Well at Time T after Pumping Stopped
​ LaTeX ​ Go Depression Head = Depression Head in Well/exp(Specific Capacity*Time)
Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present
​ LaTeX ​ Go Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303)
Depression Head in Well at Time T after Pumping Stopped and Fine Sand is Present
​ LaTeX ​ Go Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.5/2.303)*Time/3600)
Depression Head in Well at Time T after Pumping Stopped and Clay Soil is Present
​ LaTeX ​ Go Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600))

Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present Formula

​LaTeX ​Go
Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303)
hdp = hw1/10^((0.25*t/3600)/2.303)

What is Clay Soil?

Clay soil is defined by its small particle size, high plasticity, excellent nutrient retention, and poor drainage. While it can be fertile and valuable for agricultural and construction purposes, its characteristics can also pose challenges in managing water and supporting healthy plant growth. Understanding clay soil's properties is essential for effective land management and agricultural practices.

How to Calculate Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present?

Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present calculator uses Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303) to calculate the Depression Head after Pumping Stopped, The Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present formula is defined as the calculation of value of depression head in well when we have prior information of other parameters used. Depression Head after Pumping Stopped is denoted by hdp symbol.

How to calculate Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present using this online calculator? To use this online calculator for Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present, enter Depression Head in Well 1 (hw1) & Time (t) and hit the calculate button. Here is how the Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present calculation can be explained with given input values -> 1.103837 = 3/10^((0.25*14400/3600)/2.303).

FAQ

What is Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present?
The Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present formula is defined as the calculation of value of depression head in well when we have prior information of other parameters used and is represented as hdp = hw1/10^((0.25*t/3600)/2.303) or Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303). Depression Head in Well 1 is the depression head in the well when pumping stopped & Time refers to the ongoing and continuous sequence of events that occur in succession, from the past through the present to the future.
How to calculate Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present?
The Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present formula is defined as the calculation of value of depression head in well when we have prior information of other parameters used is calculated using Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600)/2.303). To calculate Depression Head in Well at Time T after Pumping Stopped with Base 10 and Clay soil is Present, you need Depression Head in Well 1 (hw1) & Time (t). With our tool, you need to enter the respective value for Depression Head in Well 1 & Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Depression Head after Pumping Stopped?
In this formula, Depression Head after Pumping Stopped uses Depression Head in Well 1 & Time. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.25*Time/3600))
  • Depression Head after Pumping Stopped = Depression Head in Well 1/10^((0.5/2.303)*Time/3600)
  • Depression Head after Pumping Stopped = (Depression Head in Well 1/10^(((0.5)*(Time/3600)/2.303)))