Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time
KD = log10(Dc*f/Lt)/tc
This formula uses 1 Functions, 5 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is referred as the value obtained after decomposing of oxygen in sewage.
Critical Oxygen Deficit - Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate.
Self-Purification Constant - Self-Purification Constant is referred as the ratio of reoxygenation constant to deoxygenation constant.
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - The Oxygen Equivalent is referred as the oxidizable organic matter present in sewage.
Critical Time - (Measured in Second) - Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time.
STEP 1: Convert Input(s) to Base Unit
Critical Oxygen Deficit: 0.0003 --> No Conversion Required
Self-Purification Constant: 0.9 --> No Conversion Required
Oxygen Equivalent: 0.21 Milligram per Liter --> 0.00021 Kilogram per Cubic Meter (Check conversion ​here)
Critical Time: 0.5 Day --> 43200 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KD = log10(Dc*f/Lt)/tc --> log10(0.0003*0.9/0.00021)/43200
Evaluating ... ...
KD = 2.5264923478025E-06
STEP 3: Convert Result to Output's Unit
2.5264923478025E-06 1 Per Second -->0.218288938850136 1 Per Day (Check conversion ​here)
FINAL ANSWER
0.218288938850136 0.218289 1 Per Day <-- Deoxygenation Constant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Deoxygenation Coefficient Calculators

Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit
​ Go Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time
Deoxygenation Coefficient given Self Purification Constant
​ Go Deoxygenation Constant = Reoxygenation Coefficient/Self-Purification Constant

Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit Formula

Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time
KD = log10(Dc*f/Lt)/tc

What is Critical Oxygen Deficit?

The Critical Oxygen Deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.

How to Calculate Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit?

Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit calculator uses Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time to calculate the Deoxygenation Constant, The Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit formula is defined as the rate at which dissolved oxygen (DO) is consumed in a body of water due to biochemical processes, primarily the microbial decomposition of organic matter. Deoxygenation Constant is denoted by KD symbol.

How to calculate Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit using this online calculator? To use this online calculator for Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit, enter Critical Oxygen Deficit (Dc), Self-Purification Constant (f), Oxygen Equivalent (Lt) & Critical Time (tc) and hit the calculate button. Here is how the Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit calculation can be explained with given input values -> -11568.405248 = log10(0.0003*0.9/0.00021)/43200.

FAQ

What is Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit?
The Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit formula is defined as the rate at which dissolved oxygen (DO) is consumed in a body of water due to biochemical processes, primarily the microbial decomposition of organic matter and is represented as KD = log10(Dc*f/Lt)/tc or Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time. Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate, Self-Purification Constant is referred as the ratio of reoxygenation constant to deoxygenation constant, The Oxygen Equivalent is referred as the oxidizable organic matter present in sewage & Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time.
How to calculate Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit?
The Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit formula is defined as the rate at which dissolved oxygen (DO) is consumed in a body of water due to biochemical processes, primarily the microbial decomposition of organic matter is calculated using Deoxygenation Constant = log10(Critical Oxygen Deficit*Self-Purification Constant/Oxygen Equivalent)/Critical Time. To calculate Deoxygenation Constant given Self Purification Constant with Critical Oxygen Deficit, you need Critical Oxygen Deficit (Dc), Self-Purification Constant (f), Oxygen Equivalent (Lt) & Critical Time (tc). With our tool, you need to enter the respective value for Critical Oxygen Deficit, Self-Purification Constant, Oxygen Equivalent & Critical Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Deoxygenation Constant?
In this formula, Deoxygenation Constant uses Critical Oxygen Deficit, Self-Purification Constant, Oxygen Equivalent & Critical Time. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Deoxygenation Constant = Reoxygenation Coefficient/Self-Purification Constant