Deoxygenation Constant at 20 degree Celsius Solution

STEP 0: Pre-Calculation Summary
Formula Used
Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20))
KD(20) = KD(T)/(1.047^(T-20))
This formula uses 3 Variables
Variables Used
Deoxygenation Constant at Temperature 20 - (Measured in 1 Per Second) - Deoxygenation Constant at Temperature 20 refers to the BOD rate constant at temperature 20°C.
Deoxygenation Constant at Temperature T - (Measured in 1 Per Second) - Deoxygenation Constant at temperature T refers to the BOD rate constant at temperature T.
Temperature - (Measured in Kelvin) - Temperature refers to the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Deoxygenation Constant at Temperature T: 0.15 1 Per Day --> 1.73611111111111E-06 1 Per Second (Check conversion ​here)
Temperature: 10 Kelvin --> 10 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KD(20) = KD(T)/(1.047^(T-20)) --> 1.73611111111111E-06/(1.047^(10-20))
Evaluating ... ...
KD(20) = 2.74817467615366E-06
STEP 3: Convert Result to Output's Unit
2.74817467615366E-06 1 Per Second -->0.237442292019676 1 Per Day (Check conversion ​here)
FINAL ANSWER
0.237442292019676 0.237442 1 Per Day <-- Deoxygenation Constant at Temperature 20
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Deoxygenation Constant Calculators

Deoxygenation Constant given Total Amount of Organic Matter Oxidised
​ LaTeX ​ Go Deoxygenation Constant = -(1/Time in Days)*log10(1-(Organic Matter Oxidised/Organic Matter at Start s))
Deoxygenation Constant given Organic Matter Present at Start of BOD
​ LaTeX ​ Go Deoxygenation Constant = -(1/Time in Days)*log10(Oxygen Equivalent/Organic Matter at Start s)
Deoxygenation Constant at given Temperature
​ LaTeX ​ Go Deoxygenation Constant at Temperature T = Deoxygenation Constant at Temperature 20*(1.047)^(Temperature-20)
De-oxygenation Constant
​ LaTeX ​ Go Deoxygenation Constant = 0.434*Rate Constant in BOD

Deoxygenation Constant at 20 degree Celsius Formula

​LaTeX ​Go
Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20))
KD(20) = KD(T)/(1.047^(T-20))

What is Deoxygenation Constant at Temperature T?

Deoxygenation Constant at Temperature T is the BOD constant rate at a given temperature T on base 10. Its unit is per day.

How to Calculate Deoxygenation Constant at 20 degree Celsius?

Deoxygenation Constant at 20 degree Celsius calculator uses Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20)) to calculate the Deoxygenation Constant at Temperature 20, The Deoxygenation Constant at 20 degree Celsius formula is defined as the Temperature T is the BOD constant rate at 20°C. Its value varies between 0.05 to 0.2 per day, depending upon the nature of the organic matter present in the sewage. Deoxygenation Constant at Temperature 20 is denoted by KD(20) symbol.

How to calculate Deoxygenation Constant at 20 degree Celsius using this online calculator? To use this online calculator for Deoxygenation Constant at 20 degree Celsius, enter Deoxygenation Constant at Temperature T (KD(T)) & Temperature (T) and hit the calculate button. Here is how the Deoxygenation Constant at 20 degree Celsius calculation can be explained with given input values -> 654.7427 = 1.73611111111111E-06/(1.047^(10-20)).

FAQ

What is Deoxygenation Constant at 20 degree Celsius?
The Deoxygenation Constant at 20 degree Celsius formula is defined as the Temperature T is the BOD constant rate at 20°C. Its value varies between 0.05 to 0.2 per day, depending upon the nature of the organic matter present in the sewage and is represented as KD(20) = KD(T)/(1.047^(T-20)) or Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20)). Deoxygenation Constant at temperature T refers to the BOD rate constant at temperature T & Temperature refers to the degree or intensity of heat present in a substance or object.
How to calculate Deoxygenation Constant at 20 degree Celsius?
The Deoxygenation Constant at 20 degree Celsius formula is defined as the Temperature T is the BOD constant rate at 20°C. Its value varies between 0.05 to 0.2 per day, depending upon the nature of the organic matter present in the sewage is calculated using Deoxygenation Constant at Temperature 20 = Deoxygenation Constant at Temperature T/(1.047^(Temperature-20)). To calculate Deoxygenation Constant at 20 degree Celsius, you need Deoxygenation Constant at Temperature T (KD(T)) & Temperature (T). With our tool, you need to enter the respective value for Deoxygenation Constant at Temperature T & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!